Details describe the tested sample, not every module of the series.
RETC PV Module Index — Qcells
Year
Recognition
2023
Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test)
2024
High Achievement in Performance
2025
Performance High Achiever
2026
Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid)
Inverter compatibility & string sizing
Qcells datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.3 V
Voc when cold
per panel
30.8 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–12
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–12
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–12
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
8–10
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
48.3 / 30.8 V
✓ Within range
1.36
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
48.3 / 30.8 V
✗ Not a match: module voltage below MPPT range
1.04
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
48.3 / 30.8 V
✓ Within range
0.51
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
48.3 / 30.8 V
✓ Within range
1.22
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
48.3 / 30.8 V
⚠ Works; below MPPT at peak heat
1.13
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
662
11,916
6.08
Palmdale
1,835
725
13,047
6.69
Chula Vista
1,696
670
12,059
6.11
Huntington Beach
1,643
649
11,682
5.89
Riverside
1,696
670
12,059
6.21
Santa Clarita
1,724
681
12,258
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Who installs Q.PEAK DUO BLK ML-G10+/t panels in SoCal
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.
Installed together with
building permits
Microinverters
Enphase IQ8+
12
Batteries
Enphase IQ Battery 5P
11
Number of permits naming both this panel series and the product; 12 of 12 permits list other equipment.
Compare with similar 395 W panels
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Qcells Q.PEAK DUO BLK ML-G10+/t 395
395 W
≈20.6%
−0.374
45.52
11.04
brand 11×
12
JA Solar JAM54S31-395/MR
395 W
≈20.8%
−0.329
36.98
13.7
product 2023, 2024
152
REC Group REC395AA Pure
395 W
≈22%
−0.256
48.7
10.2
brand 9× (2016–2025)
66
LONGi LR5-54HABB-395M
395 W
≈20.8%
−0.342
36.81
13.65
brand 9× (2017–2026)
64
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Qcells
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits
ManufacturerQcells
Listed in CEC asHanwha Qcells (Qidong) Co. Ltd., Qcells North America
How efficient is the Qcells Q.PEAK DUO BLK ML-G10+/t 395?
Calculated from the panel area (1.92 m²): about 20.6% for the 395 W class. 395 W over 1.92 m² equals about 206 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.3 V, Vmp at 74 °C cell = 30.8 V). Final design must follow the inverter manual and NEC 690.7.
Does it work with Enphase IQ8PLUS-72-2-US microinverters?
Voltage check against the Enphase datasheet: Voc when cold 48.3 V vs max input 60 V; Vmp when hot 30.8 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
What does the warranty cover?
25 years on the product and 25 years linear on performance: at least 86% after 25 years (manufacturer datasheet).
Has this panel been reliability-tested?
Q.PEAK DUO BLK ML-G10+ was a PVEL Top Performer in 2022, 2023 (LID+LETID, PID) — a closely related product name.
What fire rating does it have?
UL 61730 fire rating Type 2 per datasheet.
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ SERIES 390–410 Wp”.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — City of Palmdale (Apr 2024 – Sep 2025); Los Angeles County Public Works (EPIC-LA, unincorporated areas) (May 2024 – Jun 2024). Equipment matched from permit descriptions by model number.
Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.