Cali-GrafCali-Graf
Solar panelQcells

Qcells Q.PEAK DUO BLK ML-G10+/t 395

132 half-cut cells (6 × 22). Power classes 395–400 W in the CEC list.

CEC listed · Apr 3, 2023UL 6173025-yr product + 25-yr performance warrantyInstalled in 12 SoCal permits
Power class
  • Power (STC)395 WCEC nameplate
  • Efficiency≈20.6%calculated from area
  • %/°C Pmax−0.34CEC test: −0.374
  • Degradation / yr0.5%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 2 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Q.PEAK DUO BLK ML-G10+/t 395395 W45.5211.0437.811.45≈20.6%362 WDec 2, 2024
Q.PEAK DUO BLK ML-G10+/t 400400 W45.5511.0738.0910.50≈20.8%367 WApr 3, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.92 m².
CEC note: Formerly listed under Hanwha Q CELLS

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Qcells datasheet

Heat & cold behaviour

Qcells datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.34 %/°C−0.374 %/°C
Voc coefficient β−0.27 %/°C−0.281 %/°C
Isc coefficient α+0.04 %/°C+0.041 %/°C
Vmp coefficient≈ −0.38 %/°C—
Operating cell temperature—NOCT 48.1 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

At normal operating conditions (NMOT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
395 W296.342.938.8936.108.21
400 W300.142.968.9236.338.26

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W38.8 W34.06 V × 1.14 A——
400 W283.1 W34.31 V × 8.25 A74.7 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Qcells datasheet
UL 61730IEC 61215IEC 61730Fire rating Type 2 (UL 61730)

Warranty & degradation

Qcells datasheet
80%85%90%95%100%051015202586% yr 25years
Straight line from 100% to the end-of-warranty value — linear, per datasheet.
  • Product warranty25 years
  • Performance warranty25 years, linear
  • Then≤ 0.5% / year
  • Year 25≥ 86%

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2022, 2023
PVEL Top Performer
closely related product name
2
Tests passed as Top Performer
LID+LETID, PID
11
PVEL Scorecards
Qcells named Top Performer, 2016–2026
2023, 2026
RETC Overall Highest Achiever
Qcells, manufacturer level

PVEL Top Performer tests

YearProductTests
2022Q.PEAK DUO BLK ML-G10+ (closely related product name)LID+LETIDPID
2023Q.PEAK DUO BLK ML-G10+ (closely related product name)LID+LETIDPID

Tested bill of materials

Details describe the tested sample, not every module of the series.

RETC PV Module Index — Qcells

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test)
2024High Achievement in Performance
2025Performance High Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid)

Inverter compatibility & string sizing

Qcells datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.3 V
Voc when cold
per panel
30.8 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V48.3 / 30.8 V✓ Within range1.36
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V48.3 / 30.8 V✗ Not a match: module voltage below MPPT range1.04
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V48.3 / 30.8 V✓ Within range0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V48.3 / 30.8 V✓ Within range1.22
Enphase IQ8A-72-2-US295–500 W60 V32–45 V48.3 / 30.8 V⚠ Works; below MPPT at peak heat1.13
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67666211,9166.08
Palmdale1,83572513,0476.69
Chula Vista1,69667012,0596.11
Huntington Beach1,64364911,6825.89
Riverside1,69667012,0596.21
Santa Clarita1,72468112,2586.28
778Jan779Feb999Mar1,103Apr1,090May1,158Jun1,220Jul1,234Aug1,079Sep952Oct818Nov708DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs Q.PEAK DUO BLK ML-G10+/t panels in SoCal

building permits · CSLB License Master
12
Permits naming this series
Apr 2024 – Sep 2025
1
Licensed installers
CSLB license on the permit
2
Jurisdictions so far
Palmdale (7), LA County (unincorp.) (5)

Permits over time

3Apr ’2452Jun00Aug00Oct01Dec00Feb00Apr00Jun00Aug1permits per month

Power class named in permit

395 W
9
400 W
3

Top ZIP codes

  • ZIP 935524
  • ZIP 905023
  • ZIP 935502
  • Other ZIP codes3

Typical system

median 5.9 kW, 15 panels (n = 10)

Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8+
12

Batteries

Enphase IQ Battery 5P
11
Number of permits naming both this panel series and the product; 12 of 12 permits list other equipment.

Compare with similar 395 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Qcells Q.PEAK DUO BLK ML-G10+/t 395395 W≈20.6%−0.37445.5211.04brand 11×12
JA Solar JAM54S31-395/MR395 W≈20.8%−0.32936.9813.7product 2023, 2024152
REC Group REC395AA Pure395 W≈22%−0.25648.710.2brand 9× (2016–2025)66
LONGi LR5-54HABB-395M395 W≈20.8%−0.34236.8113.65brand 9× (2017–2026)64
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Qcells

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

Q.PEAK DUO BLK ML-G10+ · 221Q.PEAK DUO BLK ML-G10.C+ · 124Q.TRON BLK M-G2+ · 40Q.TRON BLK M-G2.H+ · 33Q.TRON BLK M-G2.C+ · 24Q.TRON M-G2+ · 20

Questions & answers

How efficient is the Qcells Q.PEAK DUO BLK ML-G10+/t 395?

Calculated from the panel area (1.92 m²): about 20.6% for the 395 W class. 395 W over 1.92 m² equals about 206 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 662 kWh per year per 395 W panel in Los Angeles and about 725 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 48.3 V, Vmp at 74 °C cell = 30.8 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 48.3 V vs max input 60 V; Vmp when hot 30.8 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on the product and 25 years linear on performance: at least 86% after 25 years (manufacturer datasheet).

Has this panel been reliability-tested?

Q.PEAK DUO BLK ML-G10+ was a PVEL Top Performer in 2022, 2023 (LID+LETID, PID) — a closely related product name.

What fire rating does it have?

UL 61730 fire rating Type 2 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ SERIES 390–410 Wp”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — City of Palmdale (Apr 2024 – Sep 2025); Los Angeles County Public Works (EPIC-LA, unincorporated areas) (May 2024 – Jun 2024). Equipment matched from permit descriptions by model number.
  9. Contractors State License Board — License Master (contractor names and license status), as of Oct 5, 2026.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).