60 cells (6 × 10). Power classes 285–305 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| Q.PEAK BLK-G4.1 285 | 285 W | 38.91 | 9.56 | 31.73 | 8.98 | ≈17.1% | 261 W | — |
| Q.PEAK BLK-G4.1 290 | 290 W | 38.19 | 9.63 | 31.96 | 9.07 | ≈17.4% | 266 W | Sep 1, 2017 |
| Q.PEAK BLK-G4.1 295 | 295 W | 39.48 | 9.70 | 32.19 | 9.17 | ≈17.7% | 271 W | Sep 1, 2017 |
| Q.PEAK BLK-G4.1 300 | 300 W | 39.76 | 9.77 | 32.41 | 9.26 | ≈18.0% | 275 W | Aug 1, 2017 |
| Q.PEAK BLK-G4.1 305 | 305 W | 40.05 | 9.84 | 32.62 | 9.35 | ≈18.3% | 281 W | Feb 3, 2020 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.39 %/°C | −0.392 %/°C |
| Voc coefficient β | −0.28 %/°C | −0.288 %/°C |
| Isc coefficient α | +0.04 %/°C | +0.039 %/°C |
| Vmp coefficient | — | −0.386 %/°C |
| Operating cell temperature | NMOT 45 °C | NOCT 46 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 285 W | 210.7 W | 29.26 V × 7.2 A | 56.1 W | 98% |
| 290 W | 209.8 W | 29.52 V × 7.11 A | 55.8 W | 96% |
| 295 W | 209.8 W | 29.52 V × 7.11 A | 55.8 W | 95% |
| 300 W | 209.8 W | 29.52 V × 7.11 A | 55.8 W | 93% |
| 305 W | 218.6 W | 30.43 V × 7.18 A | 57.3 W | 94% |
| Year | Recognition |
|---|---|
| 2023 | Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test) |
| 2024 | High Achievement in Performance |
| 2025 | Performance High Achiever |
| 2026 | Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid) |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–14 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 4–14 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–14 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 42 / 26.1 V | ⚠ Works; below MPPT at peak heat | 1.02 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 42 / 26.1 V | ⚠ Works; below MPPT at peak heat | 0.38 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 42 / 26.1 V | ⚠ Works; below MPPT at peak heat | 0.91 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 42 / 26.1 V | ⚠ Works; below MPPT at peak heat | 0.85 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 494 | 11,866 | 6.08 |
| Palmdale | 1,835 | 541 | 12,992 | 6.69 |
| Chula Vista | 1,696 | 500 | 12,008 | 6.11 |
| Huntington Beach | 1,643 | 485 | 11,632 | 5.89 |
| Riverside | 1,696 | 500 | 12,008 | 6.21 |
| Santa Clarita | 1,724 | 509 | 12,206 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | Size | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|---|
| Qcells Q.PEAK BLK-G4.1 295 | 295 W | ≈17.7% | −0.392 | 39.48 | 9.7 | 65.7 × 39.4 in | brand 11× | — |
| REC Group REC295NP | 295 W | ≈18.2% | −0.351 | 39.4 | 9.76 | — | brand 9× (2016–2025) | 4 |
| Silfab Solar SIL295NL | 295 W | ≈17.4% | −0.379 | 40 | 9.61 | 66.9 × 39.4 in | brand 7× (2017–2025) | 2 |
| Mission Solar Energy MSE300TS60 | 300 W | ≈17.9% | −0.403 | 40 | 9.83 | 65.9 × 39.4 in | brand 2× (2024–2025) | 1 |
Calculated from the panel area (1.67 m²): about 17.7% for the 295 W class. 295 W over 1.67 m² equals about 177 W per square meter.
PVWatts v8 with typical-year weather gives about 494 kWh per year per 295 W panel in Los Angeles and about 541 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.39 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.2% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42 V, Vmp at 74 °C cell = 26.1 V). Final design must follow the inverter manual and NEC 690.7.
12 years on the product (manufacturer datasheet).
65.7 × 39.4 × 1.26 in (1,670 × 1,000 × 32 mm), 41.4 lb (18.8 kg).
This exact series is not in published PVEL Top Performer tables; Qcells was named a Top Performer in 11 Scorecards (2016–2026). RETC named Qcells Overall Highest Achiever in 2023, 2026.