Cali-GrafCali-Graf
Solar panelQcells

Qcells Q.PEAK BLK-G4.1 295

60 cells (6 × 10). Power classes 285–305 W in the CEC list.

CEC listed · Aug 1, 2017UL 1703
Power class
  • Power (STC)295 WCEC nameplate
  • Efficiency≈17.7%calculated from area
  • %/°C Pmax−0.39CEC test: −0.392
  • PTC / STC91.7%PTC 271 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Q.PEAK BLK-G4.1 285285 W38.919.5631.738.98≈17.1%261 W—
Q.PEAK BLK-G4.1 290290 W38.199.6331.969.07≈17.4%266 WSep 1, 2017
Q.PEAK BLK-G4.1 295295 W39.489.7032.199.17≈17.7%271 WSep 1, 2017
Q.PEAK BLK-G4.1 300300 W39.769.7732.419.26≈18.0%275 WAug 1, 2017
Q.PEAK BLK-G4.1 305305 W40.059.8432.629.35≈18.3%281 WFeb 3, 2020
≈ efficiency = Pmax ÷ panel area 1.67 m² (datasheet size).
CEC note: Formerly listed under Hanwha Q CELLS

Build & dimensions

Qcells datasheet · Cali-Graf calculation

Heat & cold behaviour

Qcells datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.39 %/°C−0.392 %/°C
Voc coefficient β−0.28 %/°C−0.288 %/°C
Isc coefficient α+0.04 %/°C+0.039 %/°C
Vmp coefficient—−0.386 %/°C
Operating cell temperatureNMOT 45 °CNOCT 46 °C

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
285 W210.7 W29.26 V × 7.2 A56.1 W98%
290 W209.8 W29.52 V × 7.11 A55.8 W96%
295 W209.8 W29.52 V × 7.11 A55.8 W95%
300 W209.8 W29.52 V × 7.11 A55.8 W93%
305 W218.6 W30.43 V × 7.18 A57.3 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Qcells datasheet
UL 1703IEC 61215IEC 61730

Warranty & degradation

Qcells datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
11
PVEL Scorecards
Qcells named Top Performer, 2016–2026
2023, 2026
RETC Overall Highest Achiever
Qcells, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Qcells

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Module efficiency, Pan file performance); High Achievement in Reliability (Damp heat test, Pid resistance, Thermal cycle test)
2024High Achievement in Performance
2025Performance High Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Conversion efficiency, Iam, Letid, Lid, PTC-to-STC, Temperature coefficient); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Sdml, Tc, Uvid, Budt, Damp heat, Hdt, Pid)

Inverter compatibility & string sizing

Qcells datasheet · CEC PV Module List (Oct 7, 2026) · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42 V
Voc when cold
per panel
26.1 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V42 / 26.1 V⚠ Works; below MPPT at peak heat1.02
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V42 / 26.1 V⚠ Works; below MPPT at peak heat0.38
Enphase IQ8M-72-2-US260–460 W60 V30–45 V42 / 26.1 V⚠ Works; below MPPT at peak heat0.91
Enphase IQ8A-72-2-US295–500 W60 V32–45 V42 / 26.1 V⚠ Works; below MPPT at peak heat0.85
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67649411,8666.08
Palmdale1,83554112,9926.69
Chula Vista1,69650012,0086.11
Huntington Beach1,64348511,6325.89
Riverside1,69650012,0086.21
Santa Clarita1,72450912,2066.28
775Jan775Feb995Mar1,099Apr1,085May1,153Jun1,215Jul1,229Aug1,075Sep948Oct815Nov705DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 295 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizePVEL (product / brand)SoCal permits (series)
Qcells Q.PEAK BLK-G4.1 295295 W≈17.7%−0.39239.489.765.7 × 39.4 inbrand 11×—
REC Group REC295NP295 W≈18.2%−0.35139.49.76—brand 9× (2016–2025)4
Silfab Solar SIL295NL295 W≈17.4%−0.379409.6166.9 × 39.4 inbrand 7× (2017–2025)2
Mission Solar Energy MSE300TS60300 W≈17.9%−0.403409.8365.9 × 39.4 inbrand 2× (2024–2025)1
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Qcells

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

Q.PEAK DUO BLK ML-G10+ · 221Q.PEAK DUO BLK ML-G10.C+ · 124Q.TRON BLK M-G2+ · 40Q.TRON BLK M-G2.H+ · 33Q.TRON BLK M-G2.C+ · 24Q.TRON M-G2+ · 20

Questions & answers

How efficient is the Qcells Q.PEAK BLK-G4.1 295?

Calculated from the panel area (1.67 m²): about 17.7% for the 295 W class. 295 W over 1.67 m² equals about 177 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 494 kWh per year per 295 W panel in Los Angeles and about 541 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.39 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42 V, Vmp at 74 °C cell = 26.1 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

12 years on the product (manufacturer datasheet).

How big and heavy is it?

65.7 × 39.4 × 1.26 in (1,670 × 1,000 × 32 mm), 41.4 lb (18.8 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Qcells was named a Top Performer in 11 Scorecards (2016–2026). RETC named Qcells Overall Highest Achiever in 2023, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK BLK-G4.1 285-295 Q.ANTUM SOLAR MODULE The new high-performance module Q.PEAK BLK-G4.1 is the ideal solu-”.
  3. Silfab Solar — datasheet SIL-310 NL BAA JUST ARRA -IN-.
  4. Mission Solar Energy — datasheet PERC-60-305-310-1.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  6. RETC — PV Module Index reports 2023–2026.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).