Cali-GrafCali-Graf
Solar panelPT. NUSA SOLAR INDONESIA

PT. NUSA SOLAR INDONESIA NS425M10T-B54yy

108 cells. Power classes 405–445 W in the CEC list.

CEC listed · May 1, 2025UL 61730
Power class
  • Power (STC)425 WCEC nameplate
  • Efficiency≈21.8%calculated from area
  • %/°C Pmax−0.294CEC listing test
  • PTC / STC94%PTC 399 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
NS405M10T-B54yy405 W38.4413.5331.8312.75≈20.8%380 WMay 1, 2025
NS410M10T-B54yy410 W38.6413.6032.0312.82≈21.0%385 WMay 1, 2025
NS415M10T-B54yy415 W38.8413.6732.2312.89≈21.3%390 WMay 1, 2025
NS420M10T-B54yy420 W39.0413.7432.4312.96≈21.5%395 WMay 1, 2025
NS425M10T-B54yy425 W39.2413.8132.6313.03≈21.8%399 WMay 1, 2025
NS430M10T-B54yy430 W39.4413.8832.8313.10≈22.1%404 WMay 1, 2025
NS435M10T-B54yy435 W39.6413.9533.0313.17≈22.3%409 WMay 1, 2025
NS440M10T-B54yy440 W39.8414.0233.2413.24≈22.6%414 WMay 1, 2025
NS445M10T-B54yy445 W40.0414.0933.4513.31≈22.8%419 WMay 1, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.294 %/°C
Voc coefficient β−0.241 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 46.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
405 W302.9 W29.63 V × 10.22 A79.4 W98%
410 W306.5 W29.82 V × 10.28 A80.3 W98%
415 W310.1 W30.01 V × 10.33 A81.3 W98%
420 W313.7 W30.19 V × 10.39 A82.2 W98%
425 W317.4 W30.38 V × 10.45 A83.2 W98%
430 W321 W30.57 V × 10.5 A84.1 W98%
435 W324.7 W30.75 V × 10.56 A85.1 W98%
440 W328.5 W30.95 V × 10.61 A86.1 W98%
445 W332.3 W31.14 V × 10.67 A87.1 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41.4 V
Voc when cold
per panel
27.2 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41.4 / 27.2 V⚠ Works; below MPPT at peak heat1.47
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V41.4 / 27.2 V✗ Not a match: module voltage below MPPT range1.12
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41.4 / 27.2 V⚠ Works; below MPPT at peak heat0.54
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41.4 / 27.2 V⚠ Works; below MPPT at peak heat1.31
Enphase IQ8A-72-2-US295–500 W60 V32–45 V41.4 / 27.2 V⚠ Works; below MPPT at peak heat1.22
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67671211,3976.08
Palmdale1,83578012,4786.69
Chula Vista1,69672111,5336.11
Huntington Beach1,64369811,1725.89
Riverside1,69672111,5336.21
Santa Clarita1,72473311,7236.28
744Jan745Feb955Mar1,055Apr1,042May1,108Jun1,167Jul1,180Aug1,032Sep911Oct783Nov677DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 425 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
PT. NUSA SOLAR INDONESIA NS425M10T-B54yy425 W≈21.8%−0.29439.2413.81———
Canadian Solar CS3N-425MS425 W≥20.9%−0.33245.511.825 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 425425 W≥21.8%−0.27639.0313.6625 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-425QD425 W≈21.8%−0.29438.8813.6825 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PT. NUSA SOLAR INDONESIA NS425M10T-B54yy?

Calculated from the panel area (1.95 m²): about 21.8% for the 425 W class. 425 W over 1.95 m² equals about 218 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 712 kWh per year per 425 W panel in Los Angeles and about 780 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.294 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41.4 V, Vmp at 74 °C cell = 27.2 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).