144 half-cut cells. Power classes 530–555 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| NUSA144H-530MT | 530 W | 49.20 | 13.71 | 41.35 | 12.82 | ≈20.5% | 499 W | Sep 21, 2023 |
| NUSA144H-535MT | 535 W | 49.35 | 13.78 | 41.50 | 12.90 | ≈20.7% | 504 W | Sep 21, 2023 |
| NUSA144H-540MT | 540 W | 49.50 | 13.85 | 41.65 | 12.97 | ≈20.9% | 509 W | Sep 21, 2023 |
| NUSA144H-545MT | 545 W | 49.65 | 13.92 | 41.80 | 13.04 | ≈21.1% | 514 W | Sep 21, 2023 |
| NUSA144H-550MT | 550 W | 49.80 | 13.99 | 41.95 | 13.11 | ≈21.3% | 518 W | Sep 21, 2023 |
| NUSA144H-555MT | 555 W | 49.95 | 14.02 | 42.09 | 13.18 | ≈21.5% | 523 W | Sep 21, 2023 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.337 %/°C |
| Voc coefficient β | −0.286 %/°C |
| Isc coefficient α | +0.040 %/°C |
| Operating cell temperature | NOCT 43.1 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 530 W | 405.9 W | 38.97 V × 10.42 A | 103 W | 97% |
| 535 W | 409.9 W | 39.11 V × 10.48 A | 104 W | 97% |
| 540 W | 413.6 W | 39.25 V × 10.54 A | 105 W | 97% |
| 545 W | 417.3 W | 39.39 V × 10.59 A | 105.9 W | 97% |
| 550 W | 421.1 W | 39.53 V × 10.65 A | 106.9 W | 97% |
| 555 W | 424.7 W | 39.67 V × 10.71 A | 107.8 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52.8 / 34 V | ✗ Not a match: module voltage below MPPT range | 1.42 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.8 / 34 V | ✓ Within range | 0.69 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 905 | 11,766 | 6.08 |
| Palmdale | 1,835 | 991 | 12,882 | 6.69 |
| Chula Vista | 1,696 | 916 | 11,906 | 6.11 |
| Huntington Beach | 1,643 | 887 | 11,534 | 5.89 |
| Riverside | 1,696 | 916 | 11,906 | 6.21 |
| Santa Clarita | 1,724 | 931 | 12,102 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| PT IDN SOLAR TECH NUSA144H-540MT | 540 W | ≈20.9% | −0.337 | 49.5 | 13.85 | brand 1× | — |
| JA Solar JAM72D30-540/MB | 540 W | ≈21.4% | −0.330 | 49.6 | 13.86 | product 2023, 2024 | 3 |
| Canadian Solar CS6W-540MB-AG | 540 W | ≈21% | −0.324 | 49.2 | 13.9 | product 2024 | 1 |
| LONGi LR5-72HBD-540M | 540 W | ≥21.1% | −0.354 | 49.5 | 13.85 | product 2026 | 1 |
Calculated from the panel area (2.58 m²): about 20.9% for the 540 W class. 540 W over 2.58 m² equals about 209 W per square meter.
PVWatts v8 with typical-year weather gives about 905 kWh per year per 540 W panel in Los Angeles and about 991 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.337 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.8 V, Vmp at 74 °C cell = 34 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.8 V vs max input 60 V; Vmp when hot 34 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; PT IDN SOLAR TECH was named a Top Performer in 1 Scorecard (2024).