144 half-cut cells. Power classes 370–450 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| NUSA144H-370M | 370 W | 48.10 | 9.91 | 39.70 | 9.31 | ≈18.4% | 345 W | Mar 11, 2021 |
| NUSA144H-375M | 375 W | 48.30 | 9.95 | 40.00 | 9.37 | ≈18.7% | 350 W | Mar 11, 2021 |
| NUSA144H-380M | 380 W | 48.50 | 10.00 | 40.30 | 9.42 | ≈18.9% | 354 W | Mar 11, 2021 |
| NUSA144H-385M | 385 W | 48.70 | 10.06 | 40.60 | 9.49 | ≈19.2% | 359 W | Mar 11, 2021 |
| NUSA144H-390M | 390 W | 49.00 | 10.12 | 40.80 | 9.55 | ≈19.4% | 364 W | Mar 11, 2021 |
| NUSA144H-395M | 395 W | 49.20 | 10.19 | 41.10 | 9.62 | ≈19.7% | 369 W | Mar 11, 2021 |
| NUSA144H-400M | 400 W | 49.50 | 10.26 | 41.30 | 9.69 | ≈19.9% | 374 W | Mar 11, 2021 |
| NUSA144H-405M | 405 W | 49.80 | 10.32 | 41.50 | 9.75 | ≈20.1% | 378 W | Mar 11, 2021 |
| NUSA144H-410M | 410 W | 50.10 | 10.38 | 41.80 | 9.82 | ≈20.4% | 383 W | Mar 11, 2021 |
| NUSA144H-425M | 425 W | 49.30 | 11.03 | 40.60 | 10.48 | ≈19.5% | 397 W | May 3, 2021 |
| NUSA144H-430M | 430 W | 49.50 | 11.09 | 40.80 | 10.55 | ≈19.7% | 402 W | May 3, 2021 |
| NUSA144H-435M | 435 W | 49.70 | 11.16 | 41.00 | 10.61 | ≈20.0% | 406 W | May 3, 2021 |
| NUSA144H-440M | 440 W | 49.90 | 11.23 | 41.20 | 10.68 | ≈20.2% | 411 W | May 3, 2021 |
| NUSA144H-445M | 445 W | 50.10 | 11.29 | 41.40 | 10.75 | ≈20.4% | 416 W | May 3, 2021 |
| NUSA144H-450M | 450 W | 50.30 | 11.36 | 41.60 | 10.82 | ≈20.6% | 421 W | May 3, 2021 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.379 %/°C |
| Voc coefficient β | −0.319 %/°C |
| Isc coefficient α | +0.045 %/°C |
| Operating cell temperature | NOCT 43.1 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 370 W | 62.4 W | 8.68 V × 7.19 A | — | — |
| 375 W | 63.2 W | 8.74 V × 7.24 A | — | — |
| 380 W | 273.4 W | 37.58 V × 7.28 A | 73.3 W | 96% |
| 385 W | 277.5 W | 37.86 V × 7.33 A | 74.4 W | 97% |
| 390 W | 280.6 W | 38.04 V × 7.38 A | 75.2 W | 96% |
| 395 W | 284.7 W | 38.32 V × 7.43 A | 76.3 W | 97% |
| 400 W | 288.2 W | 38.51 V × 7.48 A | 77.3 W | 97% |
| 405 W | 291.4 W | 38.7 V × 7.53 A | 78.1 W | 96% |
| 410 W | 295.6 W | 38.98 V × 7.58 A | 79.2 W | 97% |
| 425 W | 323.1 W | 39.02 V × 8.28 A | 81.5 W | 96% |
| 430 W | 326.8 W | 39.21 V × 8.34 A | 82.4 W | 96% |
| 435 W | 330.3 W | 39.4 V × 8.38 A | 83.3 W | 96% |
| 440 W | 334.1 W | 39.59 V × 8.44 A | 84.3 W | 96% |
| 445 W | 337.9 W | 39.79 V × 8.49 A | 85.2 W | 96% |
| 450 W | 341.8 W | 39.98 V × 8.55 A | 86.2 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 53.5 / 32.9 V | ✓ Within range | 1.4 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 53.5 / 32.9 V | ✗ Not a match: module voltage below MPPT range | 1.07 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 53.5 / 32.9 V | ✓ Within range | 0.52 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 53.5 / 32.9 V | ✓ Within range | 1.25 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 53.5 / 32.9 V | ✓ Within range | 1.16 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 679 | 11,539 | 6.08 |
| Palmdale | 1,835 | 743 | 12,634 | 6.69 |
| Chula Vista | 1,696 | 687 | 11,677 | 6.11 |
| Huntington Beach | 1,643 | 665 | 11,312 | 5.89 |
| Riverside | 1,696 | 687 | 11,677 | 6.21 |
| Santa Clarita | 1,724 | 698 | 11,870 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| PT IDN SOLAR TECH NUSA144H-405M | 405 W | ≈20.1% | −0.379 | 49.8 | 10.32 | brand 1× | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 405 | 405 W | ≥20.6% | −0.362 | 45.34 | 11.17 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-405/MR | 405 W | ≈21.3% | −0.329 | 37.23 | 13.87 | product 2023, 2024 | 152 |
| REC Group REC405AA Pure | 405 W | ≈22.6% | −0.256 | 48.9 | 10.3 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (2.01 m²): about 20.1% for the 405 W class. 405 W over 2.01 m² equals about 201 W per square meter.
PVWatts v8 with typical-year weather gives about 679 kWh per year per 405 W panel in Los Angeles and about 743 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.379 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 53.5 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 53.5 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; PT IDN SOLAR TECH was named a Top Performer in 1 Scorecard (2024).