Cali-GrafCali-Graf
Solar panelPT IDN SOLAR TECH

PT IDN SOLAR TECH IDN132H-525ND

132 half-cut cells. Power classes 515–540 W in the CEC list.

CEC listed · Apr 22, 2024UL 61730
Power class
  • Power (STC)525 WCEC nameplate
  • Efficiency≈22.2%calculated from area
  • %/°C Pmax−0.298CEC listing test
  • PTC / STC94.9%PTC 498 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
IDN132H-515ND515 W47.3913.7839.5513.04≈21.7%488 WApr 22, 2024
IDN132H-520ND520 W47.5813.8439.7413.10≈21.9%493 WApr 22, 2024
IDN132H-525ND525 W47.7813.9039.9413.16≈22.2%498 WApr 22, 2024
IDN132H-530ND530 W47.9813.9640.1413.22≈22.4%503 WApr 22, 2024
IDN132H-535ND535 W48.1814.0240.3413.28≈22.6%508 WJan 13, 2025
IDN132H-540ND540 W48.3814.0840.5413.34≈22.8%513 WJan 13, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.37 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.298 %/°C
Voc coefficient β−0.240 %/°C
Isc coefficient α+0.041 %/°C
Operating cell temperatureNOCT 43.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
515 W389.2 W37.35 V × 10.42 A97.3 W95%
520 W392.8 W37.53 V × 10.47 A98.3 W94%
525 W396.6 W37.72 V × 10.52 A99.2 W94%
530 W400.4 W37.9 V × 10.56 A100.2 W94%
535 W404.2 W38.09 V × 10.61 A101.1 W94%
540 W408.1 W38.28 V × 10.66 A102.1 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
1
PVEL Scorecards
PT IDN SOLAR TECH, 2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
50.4 V
Voc when cold
per panel
33.3 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V50.4 / 33.3 V✗ Not a match: module voltage below MPPT range1.38
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V50.4 / 33.3 V✓ Within range0.67
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67688011,4396.08
Palmdale1,83596312,5246.69
Chula Vista1,69689011,5756.11
Huntington Beach1,64386311,2135.89
Riverside1,69689011,5756.21
Santa Clarita1,72490511,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 525 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
PT IDN SOLAR TECH IDN132H-525ND525 W≈22.2%−0.29847.7813.9brand 1×—
SEG Solar SEG-525-BTD-BG525 W≈26.9%−0.29041.116.2product 2023, 2024, 2025, 20268
JA Solar JAM72D30-530/MB530 W≈21%−0.33049.313.72product 2023, 20243
Canadian Solar CS6W-525MB-AG525 W≈20.4%−0.32448.613.75product 20241
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PT IDN SOLAR TECH IDN132H-525ND?

Calculated from the panel area (2.37 m²): about 22.2% for the 525 W class. 525 W over 2.37 m² equals about 222 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 880 kWh per year per 525 W panel in Los Angeles and about 963 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.298 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 50.4 V, Vmp at 74 °C cell = 33.3 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 50.4 V vs max input 60 V; Vmp when hot 33.3 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; PT IDN SOLAR TECH was named a Top Performer in 1 Scorecard (2024).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).