Cali-GrafCali-Graf
Solar panelPT IDN SOLAR TECH

PT IDN SOLAR TECH IDN120H-480ND

120 half-cut cells. Power classes 465–495 W in the CEC list.

CEC listed · Apr 22, 2024UL 61730
Power class
  • Power (STC)480 WCEC nameplate
  • Efficiency≈22.2%calculated from area
  • %/°C Pmax−0.298CEC listing test
  • PTC / STC94.9%PTC 456 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
IDN120H-465ND465 W43.3013.7136.0212.91≈21.5%441 WApr 22, 2024
IDN120H-470ND470 W43.5013.7836.2212.98≈21.8%446 WApr 22, 2024
IDN120H-475ND475 W43.7013.8536.4213.05≈22.0%451 WApr 22, 2024
IDN120H-480ND480 W43.9013.9236.6213.12≈22.2%456 WApr 22, 2024
IDN120H-485ND485 W44.1013.9936.8213.19≈22.5%460 WApr 22, 2024
IDN120H-490ND490 W44.3014.0637.0213.26≈22.7%465 WJan 13, 2025
IDN120H-495ND495 W44.5014.1337.2213.32≈22.9%470 WJan 13, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.298 %/°C
Voc coefficient β−0.240 %/°C
Isc coefficient α+0.041 %/°C
Operating cell temperatureNOCT 43.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
465 W349.1 W33.85 V × 10.31 A87.6 W94%
470 W353 W34.04 V × 10.37 A88.6 W94%
475 W356.9 W34.23 V × 10.43 A89.5 W94%
480 W360.7 W34.41 V × 10.48 A90.5 W94%
485 W364.6 W34.6 V × 10.54 A91.5 W94%
490 W368.6 W34.79 V × 10.59 A92.5 W94%
495 W372.2 W34.98 V × 10.64 A93.4 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
1
PVEL Scorecards
PT IDN SOLAR TECH, 2024
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
46.3 V
Voc when cold
per panel
30.5 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V46.3 / 30.5 V✗ Not a match: module voltage below MPPT range1.26
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V46.3 / 30.5 V✓ Within range0.62
Enphase IQ8A-72-2-US295–500 W60 V32–45 V46.3 / 30.5 V⚠ Works; below MPPT at peak heat1.38
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67680412,0676.08
Palmdale1,83588113,2126.69
Chula Vista1,69681412,2116.11
Huntington Beach1,64378911,8305.89
Riverside1,69681412,2116.21
Santa Clarita1,72482812,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 480 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
PT IDN SOLAR TECH IDN120H-480ND480 W≈22.2%−0.29843.913.92brand 1×—
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79brand 9× (2016–2025)33
SEG Solar SEG-495-BTD-BG495 W≈25.3%−0.29039.915.82product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 480480 W≥20.7%−0.34053.6111.26product 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PT IDN SOLAR TECH IDN120H-480ND?

Calculated from the panel area (2.16 m²): about 22.2% for the 480 W class. 480 W over 2.16 m² equals about 222 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 804 kWh per year per 480 W panel in Los Angeles and about 881 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.298 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 46.3 V, Vmp at 74 °C cell = 30.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 46.3 V vs max input 60 V; Vmp when hot 30.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; PT IDN SOLAR TECH was named a Top Performer in 1 Scorecard (2024).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).