120 half-cut cells, bifacial, transparent backsheet. Power classes 345–370 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| PST-345W-m60HBi | 345 W | 41.25 | 10.53 | 34.39 | 10.03 | ≈18.8% | 322 W | May 2, 2022 |
| PST-350W-m60HBi | 350 W | 41.40 | 10.59 | 34.79 | 10.06 | ≈19.0% | 327 W | May 2, 2022 |
| PST-355W-m60HBi | 355 W | 41.60 | 10.63 | 35.14 | 10.10 | ≈19.3% | 332 W | May 2, 2022 |
| PST-360W-m60HBi | 360 W | 41.80 | 11.24 | 35.19 | 10.23 | ≈19.6% | 336 W | May 2, 2022 |
| PST-365W-m60HBi | 365 W | 42.00 | 11.30 | 35.33 | 10.33 | ≈19.8% | 341 W | May 2, 2022 |
| PST-370W-m60HBi | 370 W | 42.20 | 11.36 | 35.40 | 10.45 | ≈20.1% | 346 W | May 2, 2022 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.358 %/°C |
| Voc coefficient β | −0.295 %/°C |
| Isc coefficient α | +0.044 %/°C |
| Operating cell temperature | NOCT 43.8 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 345 W | 262.4 W | 31.02 V × 8.46 A | 65.9 W | 96% |
| 350 W | 266.2 W | 31.38 V × 8.48 A | 66.9 W | 96% |
| 355 W | 270 W | 31.7 V × 8.52 A | 67.8 W | 96% |
| 360 W | 273.8 W | 31.74 V × 8.63 A | 68.8 W | 96% |
| 365 W | 277.6 W | 31.87 V × 8.71 A | 69.7 W | 96% |
| 370 W | 281.4 W | 31.93 V × 8.81 A | 70.7 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 44.4 / 28.2 V | ⚠ Works; below MPPT at peak heat | 1.22 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 44.4 / 28.2 V | ✗ Not a match: module voltage below MPPT range | 0.93 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 44.4 / 28.2 V | ✓ Within range | 0.46 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 44.4 / 28.2 V | ⚠ Works; below MPPT at peak heat | 1.09 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 44.4 / 28.2 V | ⚠ Works; below MPPT at peak heat | 1.02 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 595 | 11,900 | 6.08 |
| Palmdale | 1,835 | 651 | 13,028 | 6.69 |
| Chula Vista | 1,696 | 602 | 12,042 | 6.11 |
| Huntington Beach | 1,643 | 583 | 11,665 | 5.89 |
| Riverside | 1,696 | 602 | 12,042 | 6.21 |
| Santa Clarita | 1,724 | 612 | 12,240 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Prism Solar Technologies PST-355W-m60HBi | 355 W | ≈19.3% | −0.358 | 41.6 | 10.63 | — | — |
| LONGi LR4-60HPB-355M | 355 W | ≈20.1% | −0.339 | 40.6 | 11.25 | product 2021, 2022 | 193 |
| REC Group REC355AA | 355 W | ≈21.1% | −0.279 | 44 | 10.19 | brand 9× (2016–2025) | 30 |
| Trina Solar TSM-355DE06X.05(II) | 355 W | ≈19.5% | −0.339 | 44.6 | 10.24 | product 2022 | 23 |
Calculated from the panel area (1.84 m²): about 19.3% for the 355 W class. 355 W over 1.84 m² equals about 193 W per square meter.
PVWatts v8 with typical-year weather gives about 595 kWh per year per 355 W panel in Los Angeles and about 651 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.358 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.5% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.4 V, Vmp at 74 °C cell = 28.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 44.4 V vs max input 60 V; Vmp when hot 28.2 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.