Cali-GrafCali-Graf
Solar panelPREMIER ENERGIES PHOTOVOLTAIC

PREMIER ENERGIES PHOTOVOLTAIC PE-535HGB

108 half-cut cells, bifacial. Power classes 385–560 W in the CEC list.

CEC listed · Jan 22, 2024UL 61730Bifacial
Power class
  • Power (STC)535 WCEC nameplate
  • Efficiency≈20.9%calculated from area
  • %/°C Pmax−0.382CEC listing test
  • PTC / STC92.7%PTC 496 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 11 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PE-385HGB385 W36.6413.4730.7612.53≈19.7%357 WJan 22, 2024
PE-390HGB390 W36.7213.5930.8812.64≈20.0%362 WJan 22, 2024
PE-395HGB395 W36.8313.7131.0412.73≈20.3%366 WJan 22, 2024
PE-400HGB400 W36.9413.8231.1312.85≈20.5%371 WJan 22, 2024
PE-530HGB530 W49.4313.7041.0212.93≈20.7%491 WJan 22, 2024
PE-535HGB535 W49.5113.8241.1113.03≈20.9%496 WJan 22, 2024
PE-540HGB540 W49.6813.9441.2113.11≈21.1%501 WJan 22, 2024
PE-545HGB545 W49.7613.9941.3013.21≈21.3%505 WJan 22, 2024
PE-550HGB550 W49.8214.0641.3813.31≈21.5%510 WJan 22, 2024
PE-555HGB555 W49.8814.1241.4113.40≈21.7%515 WJan 22, 2024
PE-560HGB560 W49.9114.2141.4313.52≈21.9%520 WJan 22, 2024
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.382 %/°C
Voc coefficient β−0.285 %/°C
Isc coefficient α+0.047 %/°C
Operating cell temperatureNOCT 45.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
385 W289.1 W28.46 V × 10.16 A74.5 W97%
390 W292.8 W28.57 V × 10.25 A75.5 W97%
395 W296.4 W28.72 V × 10.32 A76.4 W97%
400 W300.1 W28.8 V × 10.42 A77.4 W97%
530 W395.9 W38.01 V × 10.41 A103.4 W98%
535 W399.8 W38.09 V × 10.5 A104.4 W98%
540 W403.2 W38.19 V × 10.56 A105.3 W97%
545 W407.2 W38.27 V × 10.64 A106.3 W98%
550 W411.1 W38.34 V × 10.72 A107.3 W98%
555 W414.2 W38.37 V × 10.79 A108.1 W97%
560 W418.1 W38.39 V × 10.89 A109.2 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard
2024
PVEL Top Performer
closely related product name
6
Tests passed as Top Performer
DH, HSS, LID+LETID, MSS, PID, TC
3
PVEL Scorecards
PREMIER ENERGIES PHOTOVOLTAIC named Top Performer, 2023–2025

PVEL Top Performer tests

YearProductTests
2024PE-xxxHGB (132) (closely related product name)DHHSSLID+LETIDMSSPIDTC
2024PE-xxxHGB (144) (closely related product name)DHHSSLID+LETIDMSSPIDTC
2024PE-xxxHGB (120) (closely related product name)DHHSSLID+LETIDMSSPIDTC
2024PE-xxxHGB (108) (closely related product name)DHHSSLID+LETIDMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.8 V
Voc when cold
per panel
32.5 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.8 / 32.5 V✗ Not a match: module voltage below MPPT range1.41
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.8 / 32.5 V✓ Within range0.69
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67689711,6576.08
Palmdale1,83598212,7626.69
Chula Vista1,69690711,7966.11
Huntington Beach1,64387911,4275.89
Riverside1,69690711,7966.21
Santa Clarita1,72492211,9906.28
761Jan762Feb977Mar1,079Apr1,066May1,133Jun1,193Jul1,207Aug1,056Sep931Oct801Nov693DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 535 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
PREMIER ENERGIES PHOTOVOLTAIC PE-535HGB535 W≈20.9%−0.38249.5113.82brand 3×—
JA Solar JAM72D30-535/MB535 W≈21.2%−0.33049.4513.79product 2023, 20243
Canadian Solar CS6W-535MB-AG535 W≈20.8%−0.3244913.85product 20241
LONGi LR5-72HBD-535M535 W≥20.9%−0.32349.3513.78product 20261
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PREMIER ENERGIES PHOTOVOLTAIC PE-535HGB?

Calculated from the panel area (2.56 m²): about 20.9% for the 535 W class. 535 W over 2.56 m² equals about 209 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 897 kWh per year per 535 W panel in Los Angeles and about 982 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.382 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.8 V, Vmp at 74 °C cell = 32.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52.8 V vs max input 60 V; Vmp when hot 32.5 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

PE-xxxHGB (132) was a PVEL Top Performer in 2024 (DH, HSS, LID+LETID, MSS, PID, TC) — a closely related product name.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  3. LONGi — manufacturer datasheet “LR5-72HBD Suitable for distributed projects Advanced module technology delivers superior”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2023–2025.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).