Cali-GrafCali-Graf
Solar panelPREMIER ENERGIES PHOTOVOLTAIC

PREMIER ENERGIES PHOTOVOLTAIC PE-655G12HGB

132 cells, bifacial. Power classes 645–670 W in the CEC list.

CEC listed · Dec 1, 2023UL 61730Bifacial
Power class
  • Power (STC)655 WCEC nameplate
  • Efficiency≈21.1%calculated from area
  • %/°C Pmax−0.373CEC listing test
  • PTC / STC92.4%PTC 605 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PE-645G12HGB645 W45.1518.2637.2917.30≈20.7%596 WDec 1, 2023
PE-650G12HGB650 W45.3218.2937.4617.36≈20.9%600 WDec 1, 2023
PE-655G12HGB655 W45.5418.3237.6517.40≈21.1%605 WDec 1, 2023
PE-660G12HGB660 W45.7618.3437.8517.44≈21.2%610 WDec 1, 2023
PE-665G12HGB665 W45.9818.3738.0317.49≈21.4%615 WDec 1, 2023
PE-670G12HGB670 W46.1518.4138.2017.54≈21.5%619 WDec 1, 2023
≈ efficiency = Pmax ÷ CEC-listed area 3.11 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.373 %/°C
Voc coefficient β−0.281 %/°C
Isc coefficient α+0.053 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
645 W484.1 W35.16 V × 13.77 A126.8 W98%
650 W488 W35.32 V × 13.82 A127.8 W98%
655 W491.6 W35.5 V × 13.85 A128.7 W98%
660 W495.4 W35.69 V × 13.88 A129.7 W98%
665 W499.2 W35.86 V × 13.92 A130.7 W98%
670 W502.8 W36.02 V × 13.96 A131.7 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
3
PVEL Scorecards
PREMIER ENERGIES PHOTOVOLTAIC named Top Performer, 2023–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
48.5 V
Voc when cold
per panel
29.8 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,09812,0766.08
Palmdale1,8351,20213,2216.69
Chula Vista1,6961,11112,2206.11
Huntington Beach1,6431,07611,8385.89
Riverside1,6961,11112,2206.21
Santa Clarita1,7241,12912,4216.28
788Jan789Feb1,012Mar1,118Apr1,105May1,174Jun1,236Jul1,251Aug1,094Sep965Oct829Nov718DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 655 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
PREMIER ENERGIES PHOTOVOLTAIC PE-655G12HGB655 W≈21.1%−0.37345.5418.32brand 3×
Canadian Solar CS7N-655MB-AG655 W≈21.3%−0.39045.218.43product 2024
Hyundai Energy Solutions HiN-T650NJ650 W≈23.5%−0.27356.714.51brand 5× (2017–2025)
JinkoSolar JKM650N-66HL4M-BDV650 W≈24.1%−0.29950.2816.44product 2025
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PREMIER ENERGIES PHOTOVOLTAIC PE-655G12HGB?

Calculated from the panel area (3.11 m²): about 21.1% for the 655 W class. 655 W over 3.11 m² equals about 211 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,098 kWh per year per 655 W panel in Los Angeles and about 1,202 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.373 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 48.5 V, Vmp at 74 °C cell = 29.8 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; PREMIER ENERGIES PHOTOVOLTAIC was named a Top Performer in 3 Scorecards (2023–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NJ(HiN) Series (N TOPCon Bifacial) 640~645W.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2023–2025.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).