Cali-GrafCali-Graf
Solar panelPhono Solar

Phono Solar PS630M8GFH-26/RNH

156 half-cut cells. Power classes 610–655 W in the CEC list.

CEC listed · Oct 1, 2024UL 61730
Power class
  • Power (STC)630 WCEC nameplate
  • Efficiency≈22.7%calculated from area
  • %/°C Pmax−0.293CEC listing test
  • PTC / STC95.1%PTC 599 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PS610M8GFH-26/RNH610 W56.0013.6147.0012.97≈22.0%580 WOct 1, 2024
PS615M8GFH-26/RNH615 W56.2013.6547.3013.01≈22.2%585 WOct 1, 2024
PS620M8GFH-26/RNH620 W56.5013.6947.5013.05≈22.4%590 WOct 1, 2024
PS625M8GFH-26/RNH625 W56.7013.7347.8013.09≈22.6%594 WOct 1, 2024
PS630M8GFH-26/RNH630 W56.9013.7748.0013.13≈22.7%599 WOct 1, 2024
PS635M8GFH-26/RNH635 W57.1013.8148.2013.17≈22.9%604 WOct 1, 2024
PS640M8GFH-26/RNH640 W57.3013.8548.5013.21≈23.1%609 WOct 1, 2024
PS645M8GFH-26/RNH645 W57.6013.8948.7013.25≈23.3%614 WMay 1, 2026
PS650M8GFH-26/RNH650 W57.8013.9348.9013.29≈23.5%619 WMay 1, 2026
PS655M8GFH-26/RNH655 W58.0013.9749.1013.33≈23.6%624 WMay 1, 2026
≈ efficiency = Pmax ÷ CEC-listed area 2.77 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.293 %/°C
Voc coefficient β−0.225 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
610 W466.3 W45.1 V × 10.34 A114.6 W94%
615 W470.8 W45.4 V × 10.37 A115.6 W94%
620 W474.7 W45.6 V × 10.41 A116.6 W94%
625 W478.2 W45.8 V × 10.44 A117.7 W94%
630 W481.6 W46 V × 10.47 A118.7 W94%
635 W486.1 W46.3 V × 10.5 A119.3 W94%
640 W489.6 W46.5 V × 10.53 A120.4 W94%
645 W493.6 W46.7 V × 10.57 A121.4 W94%
650 W497.1 W46.9 V × 10.6 A122.4 W94%
655 W500.7 W47.1 V × 10.63 A123 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
9
PVEL Scorecards
Phono Solar named Top Performer, 2016–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
59.8 V
Voc when cold
per panel
40.1 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet2–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window6–8

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,05611,6156.08
Palmdale1,8351,15612,7176.69
Chula Vista1,6961,06811,7536.11
Huntington Beach1,6431,03511,3865.89
Riverside1,6961,06811,7536.21
Santa Clarita1,7241,08611,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 630 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Phono Solar PS630M8GFH-26/RNH630 W≈22.7%−0.29356.913.77brand 9×
Canadian Solar CS7N-630MB-AG630 W≈20.5%−0.39044.218.23product 2024
Hyundai Energy Solutions HiS-T630NJ630 W≈22.8%−0.29457.3613.9brand 5× (2017–2025)
Waaree BiN-17-630630 W≥22.5%−0.30857.0213.94product 2025, 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Phono Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

PSxxxM6H-18/VHB · 2PSxxxM13GFH-22/WNH · 1PSxxxM8GFH-24/TNH · 1PSxxxM4H-24/TH · 1PSxxxL8GFH-16/QNHPSxxxL8GFH-16/QNHB

Questions & answers

How efficient is the Phono Solar PS630M8GFH-26/RNH?

Calculated from the panel area (2.77 m²): about 22.7% for the 630 W class. 630 W over 2.77 m² equals about 227 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,056 kWh per year per 630 W panel in Los Angeles and about 1,156 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.293 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 59.8 V, Vmp at 74 °C cell = 40.1 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Phono Solar was named a Top Performer in 9 Scorecards (2016–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NJ(HiS) Series (N TOPCon Bifacial) 635~645W.
  3. Waaree — datasheet ELITE SERIES BiN-17-615-645 WEL-EPD-615-645-156-BiN-HC-04-27.05.2024 35mm.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).