CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.293 %/°C
Voc coefficient β
−0.225 %/°C
Isc coefficient α
+0.044 %/°C
Operating cell temperature
NOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
420 W
323.7 W
31.7 V × 10.21 A
80.1 W
95%
425 W
327.6 W
31.9 V × 10.27 A
81.1 W
95%
430 W
331.9 W
32.1 V × 10.34 A
82.2 W
96%
435 W
334.9 W
32.2 V × 10.4 A
83 W
95%
440 W
338.9 W
32.4 V × 10.46 A
84.1 W
96%
445 W
343.3 W
32.6 V × 10.53 A
84.9 W
95%
450 W
346.3 W
32.7 V × 10.59 A
86 W
96%
455 W
350.4 W
32.9 V × 10.65 A
86.8 W
95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Certifications
CEC PV Module List (Oct 7, 2026) · Clean Energy Council (Australia)
UL 61730IEC 61215:2021 / IEC 61730:2023
UL 61730CEC listing
IEC 61215:2021 / IEC 61730:2023TÜV SÜD Product Service GmbH, valid to May 2028
Independent reliability testing
Kiwa PVEL Scorecard
2024, 2025
PVEL Top Performer
this series
6
Tests passed as Top Performer
HSS, LID+LETID, MSS, PAN, PID, TC
9
PVEL Scorecards
Phono Solar named Top Performer, 2016–2026
PVEL Top Performer tests
Year
Product
Tests
2024
PSxxxM8GFH-18/VNH
LID+LETIDPANPID
2025
PSxxxM8GFH-18/VNH
HSSLID+LETIDMSSPIDTC
Tested bill of materials
PVEL-tested factoryChina
Cell technology (tested BOM)n-type TOPCon
Module design (tested BOM)bifacial - glass//glass
Power class range tested430-475W
Hail test ice ball40 mm
Details describe the tested sample, not every module of the series.
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
42 V
Voc when cold
per panel
27.8 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–14
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–14
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–14
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
9–11
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
42 / 27.8 V
⚠ Works; below MPPT at peak heat
1.5
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
42 / 27.8 V
✗ Not a match: module voltage below MPPT range
1.14
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
42 / 27.8 V
⚠ Works; below MPPT at peak heat
0.56
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
42 / 27.8 V
⚠ Works; below MPPT at peak heat
1.34
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
42 / 27.8 V
⚠ Works; below MPPT at peak heat
1.25
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
729
11,665
6.08
Palmdale
1,835
798
12,772
6.69
Chula Vista
1,696
738
11,804
6.11
Huntington Beach
1,643
715
11,435
5.89
Riverside
1,696
738
11,804
6.21
Santa Clarita
1,724
750
11,999
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 435 W panels
CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
Warranty
PVEL (product / brand)
SoCal permits (series)
Phono Solar PS435M8GFH-18/VNH
435 W
≈22.4%
−0.293
39.9
13.69
—
product 2024, 2025
—
Canadian Solar CS3N-430MS
430 W
≈21.8%
−0.332
45.7
11.86
25 yr
product 2023
46
Qcells Q.TRON BLK M-G2+ 435
435 W
≥22.3%
−0.276
39.6
13.82
25 / 25 yr
brand 11× (2016–2026)
40
Silfab Solar SIL-435QD
435 W
≈22.3%
−0.294
38.94
14.05
25 / 30 yr
brand 7× (2017–2025)
39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Phono Solar
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
How efficient is the Phono Solar PS435M8GFH-18/VNH?
Calculated from the panel area (1.94 m²): about 22.4% for the 435 W class. 435 W over 1.94 m² equals about 224 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 729 kWh per year per 435 W panel in Los Angeles and about 798 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.293 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.2% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 42 V, Vmp at 74 °C cell = 27.8 V). Final design must follow the inverter manual and NEC 690.7.
Is it bifacial?
Yes. Rear gain depends on mounting height and ground reflectance.
Has this panel been reliability-tested?
PSxxxM8GFH-18/VNH was a PVEL Top Performer in 2024, 2025 (HSS, LID+LETID, MSS, PAN, PID, TC).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
Clean Energy Council (Australia) — Approved PV modules list (as of Oct 8, 2026).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.