108 half-cut cells, PERC. Power classes 390–410 W in the CEC list.

CEC listed · Aug 11, 2022UL 6173025-yr product + 25-yr performance warrantyPERCSeen in 2 SoCal permits
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≥20.5%datasheet minimum
  • %/°C Pmax−0.353CEC listing test
  • Degradation / yr0.55%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Phono Solar datasheet · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PS390M6H-18/VHB390 W36.4813.3230.5012.79≥20.0%364 WAug 11, 2022
PS395M6H-18/VHB395 W36.6713.4230.6712.88≥20.2%369 WAug 11, 2022
PS400M6H-18/VHB400 W37.0413.7931.0112.90≥20.5%375 WAug 11, 2022
PS405M6H-18/VHB405 W37.2313.8731.2112.98≥20.7%380 WAug 11, 2022
PS410M6H-18/VHB410 W37.3213.9531.4513.04≥21.0%384 WSep 23, 2024

Build & dimensions

Phono Solar datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Phono Solar datasheet
DatasheetCEC listing test
Pmax coefficient γ—−0.353 %/°C
Voc coefficient β—−0.272 %/°C
Isc coefficient α—+0.054 %/°C
Vmp coefficient≈ −0.41 %/°C—
Operating cell temperatureNMOT 45 ± 2 °CNOCT 43.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

At normal operating conditions (NOCT, 800 W/m²) — datasheet

ClassPmax, WVoc, VIsc, AVmp, VImp, A
390 W290.034.4410.7628.0810.33
395 W294.034.6210.8428.2410.41
400 W298.034.8110.9228.4010.48
405 W301.034.9811.0028.5510.55
410 W305.035.1511.0928.7110.63

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W292.6 W28.78 V × 10.17 A75.6 W97%
395 W296.3 W28.94 V × 10.24 A76.5 W97%
400 W295.2 W28.36 V × 10.41 A77.3 W97%
405 W299 W28.54 V × 10.48 A78.3 W97%
410 W302.7 W28.76 V × 10.52 A79.3 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Phono Solar datasheet
Packaging: 11 per pallet · 216 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Phono Solar datasheet
UL 61730IEC 61215IEC 61730Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

Phono Solar datasheet

Independent reliability testing

Kiwa PVEL Scorecard
9
PVEL Scorecards
Phono Solar named Top Performer, 2016–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
39.4 V
Voc when cold
per panel
24.8 V
Vmp when hot
per panel
15
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–15
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–15
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–15
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V39.4 / 24.8 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V39.4 / 24.8 V✗ Not a match: module voltage below MPPT range1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V39.4 / 24.8 V⚠ Works; below MPPT at peak heat0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V39.4 / 24.8 V⚠ Works; below MPPT at peak heat1.23
Enphase IQ8A-72-2-US295–500 W60 V32–45 V39.4 / 24.8 V✗ Not a match: module voltage below MPPT range1.15
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 400 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Phono Solar PS400M6H-18/VHB400 W≥20.5%−0.35337.0413.79brand 9×2
Qcells Q.PEAK DUO BLK ML-G10+ 400400 W≥20.4%−0.36245.311.14product 2022, 2023221
JA Solar JAM54S31-400/MR400 W≈21.1%−0.32937.0713.79product 2023, 2024152
REC Group REC400AA Pure400 W≈22.3%−0.25648.810.25brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Phono Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

PSxxxM13GFH-22/WNH · 1PSxxxM8GFH-24/TNH · 1PSxxxM4H-24/TH · 1PSxxxL8GFH-16/QNHPSxxxL8GFH-16/QNHBPSxxxL8GFH-22/WNH

Questions & answers

How efficient is the Phono Solar PS400M6H-18/VHB?

The Phono Solar datasheet guarantees at least 20.5% module efficiency for the 400 W class (up to 21% for 410 W). 400 W over 1.95 m² equals about 205 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.353 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–15 panels per string (Voc at 2 °C = 39.4 V, Vmp at 74 °C cell = 24.8 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years linear on performance (manufacturer datasheet).

How big and heavy is it?

67.8 × 44.6 × 1.18 in (1,722 × 1,134 × 30 mm), 48.5 lb (22 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Phono Solar was named a Top Performer in 9 Scorecards (2016–2026).

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Phono Solar — manufacturer datasheet “MODULE SERIES HIGH EFFICIENCY MONO-PERC M6-10B-B OUTSTANDING PRODUCT PERFORMANCE”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Mar 2024 – Apr 2024). Equipment matched from permit descriptions by model number.