Cali-GrafCali-Graf
Solar panelPhono Solar

Phono Solar PS720M13GFH-22/WNHB

132 half-cut cells. Power classes 700–740 W in the CEC list.

CEC listed · May 1, 2026UL 61730
Power class
  • Power (STC)720 WCEC nameplate
  • Efficiency≈23.4%calculated from area
  • %/°C Pmax−0.291CEC listing test
  • PTC / STC95.2%PTC 686 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PS700M13GFH-22/WNHB700 W48.6018.1040.1017.44≈22.7%666 WMay 1, 2026
PS705M13GFH-22/WNHB705 W48.8018.1440.3017.48≈22.9%671 WMay 1, 2026
PS710M13GFH-22/WNHB710 W49.0018.1840.5017.52≈23.1%676 WMay 1, 2026
PS715M13GFH-22/WNHB715 W49.2018.2240.7017.56≈23.2%681 WMay 1, 2026
PS720M13GFH-22/WNHB720 W49.4018.2640.9017.60≈23.4%686 WMay 1, 2026
PS725M13GFH-22/WNHB725 W49.6018.3041.1017.64≈23.5%691 WMay 1, 2026
PS730M13GFH-22/WNHB730 W49.7018.3441.3017.68≈23.7%695 WMay 1, 2026
PS735M13GFH-22/WNHB735 W49.9018.3841.5017.72≈23.9%700 WMay 1, 2026
PS740M13GFH-22/WNHB740 W50.1018.4241.7017.76≈24.0%705 WMay 1, 2026
≈ efficiency = Pmax ÷ CEC-listed area 3.08 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.291 %/°C
Voc coefficient β−0.235 %/°C
Isc coefficient α+0.042 %/°C
Operating cell temperatureNOCT 43.1 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
700 W538.8 W39.1 V × 13.78 A133.5 W95%
705 W542.7 W39.3 V × 13.81 A134.5 W95%
710 W546.7 W39.5 V × 13.84 A135.6 W95%
715 W550.6 W39.7 V × 13.87 A136.6 W96%
720 W553.2 W39.8 V × 13.9 A137.6 W96%
725 W557.6 W40 V × 13.94 A138.3 W95%
730 W561.6 W40.2 V × 13.97 A139.3 W95%
735 W565.6 W40.4 V × 14 A140.4 W95%
740 W569.6 W40.6 V × 14.03 A141.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard
9
PVEL Scorecards
Phono Solar named Top Performer, 2016–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.1 V
Voc when cold
per panel
34.2 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,20712,0676.08
Palmdale1,8351,32113,2126.69
Chula Vista1,6961,22112,2116.11
Huntington Beach1,6431,18311,8305.89
Riverside1,6961,22112,2116.21
Santa Clarita1,7241,24112,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

About Phono Solar

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

PSxxxM6H-18/VHB · 2PSxxxM13GFH-22/WNH · 1PSxxxM8GFH-24/TNH · 1PSxxxM4H-24/TH · 1PSxxxL8GFH-16/QNHPSxxxL8GFH-16/QNHB

Questions & answers

How efficient is the Phono Solar PS720M13GFH-22/WNHB?

Calculated from the panel area (3.08 m²): about 23.4% for the 720 W class. 720 W over 3.08 m² equals about 234 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,207 kWh per year per 720 W panel in Los Angeles and about 1,321 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.291 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.1 V, Vmp at 74 °C cell = 34.2 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Phono Solar was named a Top Performer in 9 Scorecards (2016–2026).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2016–2026.
  3. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  4. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  5. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  6. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  7. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).