144 half-cut cells. Power classes 380–390 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| PS380M1-24/THB | 380 W | 48.57 | 10.05 | 39.92 | 9.52 | ≈18.9% | 356 W | Jan 21, 2021 |
| PS385M1-24/THB | 385 W | 48.85 | 10.13 | 40.24 | 9.57 | ≈19.2% | 360 W | Jan 21, 2021 |
| PS390M1-24/THB | 390 W | 49.12 | 10.20 | 40.55 | 9.62 | ≈19.4% | 365 W | Jan 21, 2021 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.359 %/°C |
| Voc coefficient β | −0.278 %/°C |
| Isc coefficient α | +0.051 %/°C |
| Operating cell temperature | NOCT 43.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 380 W | 285.4 W | 38.07 V × 7.5 A | 72.8 W | 96% |
| 385 W | 289.2 W | 38.37 V × 7.54 A | 73.7 W | 96% |
| 390 W | 292.9 W | 38.67 V × 7.58 A | 74.7 W | 96% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 52 / 32.2 V | ✓ Within range | 1.33 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52 / 32.2 V | ✗ Not a match: module voltage below MPPT range | 1.01 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52 / 32.2 V | ✓ Within range | 0.49 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 52 / 32.2 V | ✓ Within range | 1.18 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 52 / 32.2 V | ✓ Within range | 1.1 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 645 | 11,615 | 6.08 |
| Palmdale | 1,835 | 706 | 12,717 | 6.69 |
| Chula Vista | 1,696 | 653 | 11,753 | 6.11 |
| Huntington Beach | 1,643 | 633 | 11,386 | 5.89 |
| Riverside | 1,696 | 653 | 11,753 | 6.21 |
| Santa Clarita | 1,724 | 664 | 11,947 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Phono Solar PS385M1-24/THB | 385 W | ≈19.2% | −0.359 | 48.85 | 10.13 | brand 9× | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 385 | 385 W | ≥19.6% | −0.362 | 45.19 | 11.04 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-385/MR | 385 W | ≈20.3% | −0.329 | 36.71 | 13.52 | product 2023, 2024 | 152 |
| REC Group REC385AA Pure | 385 W | ≈21.5% | −0.256 | 48.5 | 10.1 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (2.01 m²): about 19.2% for the 385 W class. 385 W over 2.01 m² equals about 192 W per square meter.
PVWatts v8 with typical-year weather gives about 645 kWh per year per 385 W panel in Los Angeles and about 706 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.359 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.6% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52 V, Vmp at 74 °C cell = 32.2 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 52 V vs max input 60 V; Vmp when hot 32.2 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; Phono Solar was named a Top Performer in 9 Scorecards (2016–2026).