Cali-GrafCali-Graf
Solar panelPhiladelphia Solar

Philadelphia Solar PS-P60 275

60 cells. Power classes 270–285 W in the CEC list.

CEC listed · May 11, 2020UL 61730
Power class
  • Power (STC)275 WCEC nameplate
  • Efficiency≈17.0%calculated from area
  • %/°C Pmax−0.424CEC listing test
  • PTC / STC90.2%PTC 248 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PS-P60-270270 W38.129.1930.948.74≈16.7%243 WMay 11, 2020
PS-P60-275275 W38.209.2331.208.82≈17.0%248 WMay 11, 2020
PS-P60-280280 W38.379.3131.428.91≈17.3%253 WMay 11, 2020
PS-P60-285285 W38.679.3631.758.98≈17.6%257 WMay 11, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.62 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.424 %/°C
Voc coefficient β−0.322 %/°C
Isc coefficient α+0.061 %/°C
Operating cell temperatureNOCT 47.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
270 W192.9 W28.04 V × 6.88 A——
275 W196.3 W28.28 V × 6.94 A——
280 W199.7 W28.48 V × 7.01 A——
285 W203.3 W28.78 V × 7.07 A——
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
41 V
Voc when cold
per panel
23.8 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V41 / 23.8 V⚠ Works; below MPPT at peak heat0.95
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V41 / 23.8 V⚠ Works; below MPPT at peak heat0.35
Enphase IQ8M-72-2-US260–460 W60 V30–45 V41 / 23.8 V⚠ Works; below MPPT at peak heat0.85
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67646111,5226.08
Palmdale1,83550512,6166.69
Chula Vista1,69646611,6606.11
Huntington Beach1,64345211,2965.89
Riverside1,69646611,6606.21
Santa Clarita1,72447411,8526.28
752Jan753Feb966Mar1,067Apr1,054May1,120Jun1,180Jul1,194Aug1,044Sep921Oct791Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 275 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, A
Philadelphia Solar PS-P60 275275 W≈17%−0.42438.29.23
Hyundai Energy Solutions HiS-C275RG(BK)275 W≥17%−0.38238.189.15
ZNShine Solar ZXM6-72-275/M275 W≈13.8%−0.52444.648.44
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Philadelphia Solar PS-P60 275?

Calculated from the panel area (1.62 m²): about 17% for the 275 W class. 275 W over 1.62 m² equals about 170 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 461 kWh per year per 275 W panel in Los Angeles and about 505 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.424 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 22% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 41 V, Vmp at 74 °C cell = 23.8 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [Customized Module] RG(BK) Series (PERC) 265~285W.
  3. ZNShine Solar — manufacturer datasheet “ZXM6-72 Series Znshinesolar 5BB Monocrystalline PV Module”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).