Cali-GrafCali-Graf
Solar panelPhiladelphia Solar

Philadelphia Solar PS-M144(HCBF)-GG 525

144 half-cut cells, bifacial. Power classes 435–560 W in the CEC list.

CEC listed · May 23, 2022UL 61730Bifacial
Power class
  • Power (STC)525 WCEC nameplate
  • Efficiency≈20.4%calculated from area
  • %/°C Pmax−0.337CEC listing test
  • PTC / STC92.7%PTC 487 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 14 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
PS-M144(HCBF)-GG-435W435 W48.5011.3040.5210.75≈20.2%405 WMay 23, 2022
PS-M144(HCBF)-GG-440W440 W48.8011.3540.8210.80≈20.5%410 WMay 23, 2022
PS-M144(HCBF)-GG-445W445 W49.1011.4041.1010.84≈20.7%414 WMay 23, 2022
PS-M144(HCBF)-GG-450W450 W49.4011.4541.3910.89≈20.9%419 WMay 23, 2022
PS-M144(HCBF)-GG-455W455 W49.7011.5041.6510.94≈21.2%424 WMay 23, 2022
PS-M144(HCBF)-GG-460W460 W50.0011.5541.9010.99≈21.4%429 WMay 23, 2022
PS-M144(HCBF)-GG-525W525 W48.9513.5541.2112.75≈20.4%487 WDec 1, 2022
PS-M144(HCBF)-GG-530W530 W49.2013.6041.4612.79≈20.6%492 WDec 1, 2022
PS-M144(HCBF)-GG-535W535 W49.5013.6541.7212.83≈20.8%496 WDec 1, 2022
PS-M144(HCBF)-GG-540W540 W49.8013.7042.0012.86≈21.0%501 WDec 1, 2022
PS-M144(HCBF)-GG-545W545 W50.1013.7542.2612.90≈21.2%506 WDec 1, 2022
PS-M144(HCBF)-GG-550W550 W50.4013.8042.5012.95≈21.4%511 WDec 1, 2022
PS-M144(HCBF)-GG-555W555 W50.7013.8542.7712.99≈21.6%515 WDec 1, 2022
PS-M144(HCBF)-GG-560W560 W50.9813.9043.0013.04≈21.8%520 WDec 1, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.15 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.337 %/°C
Voc coefficient β−0.274 %/°C
Isc coefficient α+0.055 %/°C
Operating cell temperatureNOCT 47.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
435 W327.5 W38.35 V × 8.54 A81.6 W94%
440 W331.4 W38.63 V × 8.58 A82.6 W94%
445 W335 W38.89 V × 8.61 A83.5 W94%
450 W338.9 W39.17 V × 8.65 A84.5 W94%
455 W342.6 W39.42 V × 8.69 A85.4 W94%
460 W346.2 W39.65 V × 8.73 A86.3 W94%
525 W387.4 W36.79 V × 10.53 A115 W110%
530 W391 W37.02 V × 10.56 A116.1 W109%
535 W394.7 W37.25 V × 10.6 A117.2 W109%
540 W398.2 W37.5 V × 10.62 A118.2 W109%
545 W402 W37.73 V × 10.65 A119.3 W109%
550 W405.8 W37.95 V × 10.69 A120.5 W110%
555 W409.7 W38.19 V × 10.73 A121.6 W110%
560 W413.4 W38.39 V × 10.77 A122.7 W110%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52 V
Voc when cold
per panel
33.3 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52 / 33.3 V✗ Not a match: module voltage below MPPT range1.38
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52 / 33.3 V✓ Within range0.67
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67688011,4396.08
Palmdale1,83596312,5246.69
Chula Vista1,69689011,5756.11
Huntington Beach1,64386311,2135.89
Riverside1,69689011,5756.21
Santa Clarita1,72490511,7666.28
747Jan747Feb959Mar1,059Apr1,046May1,112Jun1,171Jul1,185Aug1,036Sep914Oct786Nov680DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 525 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Philadelphia Solar PS-M144(HCBF)-GG 525525 W≈20.4%−0.33748.9513.55——
SEG Solar SEG-525-BTD-BG525 W≈26.9%−0.29041.116.2product 2023, 2024, 2025, 20268
JA Solar JAM72D30-530/MB530 W≈21%−0.33049.313.72product 2023, 20243
Canadian Solar CS6W-525MB-AG525 W≈20.4%−0.32448.613.75product 20241
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Philadelphia Solar PS-M144(HCBF)-GG 525?

Calculated from the panel area (2.57 m²): about 20.4% for the 525 W class. 525 W over 2.57 m² equals about 204 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 880 kWh per year per 525 W panel in Los Angeles and about 963 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.337 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52 V, Vmp at 74 °C cell = 33.3 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 52 V vs max input 60 V; Vmp when hot 33.3 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  3. Canadian Solar — datasheet BiHiKu6 BIFACIAL MONO PERC CS6W-520|525|530|535|540|545|550MB-AG.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).