Cali-GrafCali-Graf
Solar panelPEIMAR

PEIMAR SM310M (FB)

60 cells. Power classes 295–325 W in the CEC list.

CEC listed · Jun 21, 2021UL 61730
Power class
  • Power (STC)310 WCEC nameplate
  • Efficiency≈19.0%calculated from area
  • %/°C Pmax−0.375CEC listing test
  • PTC / STC92.2%PTC 286 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SM295M (FB)295 W40.219.5032.958.98≈18.1%272 WJun 21, 2021
SM300M (FB)300 W40.459.5933.159.07≈18.4%276 WJun 21, 2021
SM305M (FB)305 W40.709.6933.359.16≈18.7%281 WJun 21, 2021
SM310M (FB)310 W40.949.7933.559.25≈19.0%286 WJun 21, 2021
SM315M (FB)315 W41.189.8933.759.34≈19.3%290 WJun 21, 2021
SM320M (FB)320 W41.429.9833.959.43≈19.6%295 WJun 21, 2021
SM325M (FB)325 W41.6710.0834.159.52≈19.9%300 WJun 21, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.63 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.375 %/°C
Voc coefficient β−0.283 %/°C
Isc coefficient α+0.057 %/°C
Operating cell temperatureNOCT 46.2 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
295 W212.5 W30.32 V × 7.01 A55.2 W94%
300 W215.9 W30.5 V × 7.08 A56.1 W94%
305 W219.4 W30.69 V × 7.15 A57 W94%
310 W222.9 W30.87 V × 7.22 A57.9 W93%
315 W226.4 W31.05 V × 7.29 A58.9 W93%
320 W229.9 W31.24 V × 7.36 A59.8 W93%
325 W233.5 W31.42 V × 7.43 A60.7 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.6 V
Voc when cold
per panel
26.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.6 / 26.4 V⚠ Works; below MPPT at peak heat1.07
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.6 / 26.4 V⚠ Works; below MPPT at peak heat0.4
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.6 / 26.4 V⚠ Works; below MPPT at peak heat0.95
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.6 / 26.4 V⚠ Works; below MPPT at peak heat0.89
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67652011,9506.08
Palmdale1,83556913,0846.69
Chula Vista1,69652612,0926.11
Huntington Beach1,64350911,7155.89
Riverside1,69652612,0926.21
Santa Clarita1,72453412,2926.28
780Jan781Feb1,002Mar1,107Apr1,093May1,161Jun1,224Jul1,238Aug1,082Sep955Oct821Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 310 W panels

CEC PV Module List (Oct 7, 2026) · JinkoSolar datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
PEIMAR SM310M (FB)310 W≈19%−0.37540.949.79—
JinkoSolar JKM310M-60HBL310 W≈18.4%−0.40740.59.9245
REC Group REC310NP310 W≈19.1%−0.35140.210.014
Sinotec USA STS-310M3B-60310 W≈18.8%−0.37540.310.043
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PEIMAR SM310M (FB)?

Calculated from the panel area (1.63 m²): about 19% for the 310 W class. 310 W over 1.63 m² equals about 190 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 520 kWh per year per 310 W panel in Los Angeles and about 569 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.375 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 19.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.6 V, Vmp at 74 °C cell = 26.4 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).