Cali-GrafCali-Graf
Solar panelPEIMAR

PEIMAR SE460M

108 cells. Power classes 385–550 W in the CEC list.

CEC listed · Nov 1, 2023UL 61730
Power class
  • Power (STC)460 WCEC nameplate
  • Efficiency≈21.9%calculated from area
  • %/°C Pmax−0.352CEC listing test
  • PTC / STC94%PTC 432 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 28 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SE385M385 W36.7013.0831.5012.23≈20.4%361 WNov 1, 2023
SE390M390 W36.8013.4131.1412.53≈20.6%366 WNov 1, 2023
SE395M395 W36.9013.5531.2012.67≈20.9%371 WNov 1, 2023
SE400M400 W37.0013.6831.3012.78≈21.2%376 WNov 1, 2023
SE405M405 W37.1013.8131.3812.91≈21.4%380 WNov 1, 2023
SE410M410 W37.2013.9431.4713.02≈21.7%385 WNov 1, 2023
SE415M415 W37.3014.0731.5513.16≈22.0%390 WNov 1, 2023
SE430M430 W40.8013.3434.5012.47≈20.5%404 WNov 1, 2023
SE435M435 W40.9013.4634.6012.58≈20.7%408 WNov 1, 2023
SE440M440 W41.0013.5734.6912.68≈21.0%413 WNov 1, 2023
SE445M445 W41.1013.6934.7812.79≈21.2%418 WNov 1, 2023
SE450M450 W41.2013.8234.8512.92≈21.4%423 WNov 1, 2023
SE455M455 W41.3013.9434.9413.02≈21.7%428 WNov 1, 2023
SE460M460 W41.4014.0335.0813.11≈21.9%432 WNov 1, 2023
SE475M475 W45.0013.3638.0712.48≈20.7%446 WNov 1, 2023
SE480M480 W45.1013.4638.1512.58≈20.9%451 WNov 1, 2023
SE485M485 W45.2013.5738.2412.69≈21.1%455 WNov 1, 2023
SE490M490 W45.3013.6838.3312.78≈21.3%460 WNov 1, 2023
SE495M495 W45.4013.7938.4112.89≈21.5%465 WNov 1, 2023
SE500M500 W45.5013.8938.5012.99≈21.7%470 WNov 1, 2023
SE505M505 W45.6013.9938.6313.08≈22.0%475 WNov 1, 2023
SE520M520 W49.2013.3741.6312.49≈20.6%488 WNov 1, 2023
SE525M525 W49.3013.4441.8012.56≈20.8%493 WNov 1, 2023
SE530M530 W49.4013.5841.7912.69≈21.0%498 WNov 1, 2023
SE535M535 W49.5013.6741.8812.78≈21.2%502 WNov 1, 2023
SE540M540 W49.6013.7841.9612.87≈21.4%507 WNov 1, 2023
SE545M545 W49.7013.8742.0512.96≈21.6%512 WNov 1, 2023
SE550M550 W49.8013.9742.1313.05≈21.8%517 WNov 1, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.89 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.352 %/°C
Voc coefficient β−0.262 %/°C
Isc coefficient α+0.035 %/°C
Operating cell temperatureNOCT 43.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
385 W282.1 W28.73 V × 9.82 A74.6 W97%
390 W285.7 W28.4 V × 10.06 A75.6 W97%
395 W289.4 W28.45 V × 10.17 A76.5 W97%
400 W292.9 W28.54 V × 10.26 A77.5 W97%
405 W296.6 W28.62 V × 10.37 A78.4 W97%
410 W300 W28.7 V × 10.45 A79.3 W97%
415 W304 W28.77 V × 10.57 A80.4 W97%
430 W316.2 W31.45 V × 10.05 A86 W100%
435 W319.9 W31.54 V × 10.14 A87 W100%
440 W323.3 W31.63 V × 10.22 A88 W100%
445 W326.9 W31.71 V × 10.31 A89 W100%
450 W330.9 W31.77 V × 10.41 A90 W100%
455 W334.3 W31.85 V × 10.5 A91 W100%
460 W338 W31.98 V × 10.57 A92 W100%
475 W353.4 W34.85 V × 10.14 A94.7 W100%
480 W357 W34.92 V × 10.22 A95.6 W100%
485 W360.9 W35 V × 10.31 A96.7 W100%
490 W364.4 W35.08 V × 10.39 A97.6 W100%
495 W368.3 W35.16 V × 10.47 A98.7 W100%
500 W372 W35.24 V × 10.56 A99.7 W100%
505 W375.8 W35.36 V × 10.63 A100.7 W100%
520 W387.2 W38.14 V × 10.15 A104.7 W101%
525 W391 W38.29 V × 10.21 A105.7 W101%
530 W394.9 W38.28 V × 10.32 A106.8 W101%
535 W398.6 W38.37 V × 10.39 A107.8 W101%
540 W402.2 W38.44 V × 10.46 A108.8 W101%
545 W405.8 W38.52 V × 10.54 A109.8 W101%
550 W409.4 W38.6 V × 10.61 A110.7 W101%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.9 V
Voc when cold
per panel
28.4 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.9 / 28.4 V✗ Not a match: module voltage below MPPT range1.21
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.9 / 28.4 V✓ Within range0.59
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.9 / 28.4 V⚠ Works; below MPPT at peak heat1.42
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.9 / 28.4 V⚠ Works; below MPPT at peak heat1.32
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677111,5646.08
Palmdale1,83584412,6626.69
Chula Vista1,69678011,7026.11
Huntington Beach1,64375611,3375.89
Riverside1,69678011,7026.21
Santa Clarita1,72479311,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 460 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
PEIMAR SE460M460 W≈21.9%−0.35241.414.03—
REC Group REC460AA Pure-RX460 W≈22.8%−0.24865.38.8833
Aptos Solar DNA-120-MF10-460W460 W≈21.3%−0.36341.71422
Canadian Solar CS6.1-54TM-460H460 W≥22.5%−0.30839.314.699
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PEIMAR SE460M?

Calculated from the panel area (2.2 m²): about 21.9% for the 460 W class. 460 W over 2.2 m² equals about 209 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 771 kWh per year per 460 W panel in Los Angeles and about 844 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.352 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.9 V, Vmp at 74 °C cell = 28.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 43.9 V vs max input 60 V; Vmp when hot 28.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).