Cali-GrafCali-Graf
Solar panelPEIMAR

PEIMAR DR10H460M

108 half-cut cells. Power classes 395–550 W in the CEC list.

CEC listed · Aug 11, 2025UL 61730
Power class
  • Power (STC)460 WCEC nameplate
  • Efficiency≈21.5%calculated from area
  • %/°C Pmax−0.355CEC listing test
  • PTC / STC93.8%PTC 431 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 20 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
DR10H395M395 W36.9013.7130.3013.03≈20.4%370 WAug 11, 2025
DR10H400M400 W37.0013.7830.4013.15≈20.6%375 WAug 11, 2025
DR10H405M405 W37.1013.8530.5013.27≈20.9%380 WAug 11, 2025
DR10H410M410 W37.1013.9230.6013.39≈21.1%384 WAug 11, 2025
DR10H415M415 W37.3014.0130.8013.48≈21.4%389 WAug 11, 2025
DR10H440M440 W41.0013.7333.7013.05≈20.6%412 WAug 11, 2025
DR10H445M445 W41.1013.7933.8013.16≈20.8%417 WAug 11, 2025
DR10H450M450 W41.2013.8533.9013.27≈21.0%422 WAug 11, 2025
DR10H455M455 W41.3013.9334.1013.36≈21.3%426 WAug 11, 2025
DR10H460M460 W41.5014.0134.2013.45≈21.5%431 WAug 11, 2025
DR10H485M485 W45.1013.6737.9312.79≈20.5%454 WJul 1, 2026
DR10H490M490 W45.2513.7438.0812.87≈20.7%459 WJul 1, 2026
DR10H495M495 W45.4013.8238.2312.95≈20.9%464 WJul 1, 2026
DR10H500M500 W45.4513.9338.2913.06≈21.1%469 WJul 1, 2026
DR10H505M505 W45.6014.0138.4313.14≈21.3%474 WJul 1, 2026
DR10H530M530 W49.3013.7140.6013.07≈20.7%496 WAug 11, 2025
DR10H535M535 W49.3013.7940.6013.17≈20.9%501 WAug 11, 2025
DR10H540M540 W49.4013.8540.7013.27≈21.1%506 WAug 11, 2025
DR10H545M545 W49.5013.9440.8013.36≈21.3%511 WAug 11, 2025
DR10H550M550 W49.6014.0340.9013.45≈21.5%516 WAug 11, 2025
≈ efficiency = Pmax ÷ CEC-listed area 1.94 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.355 %/°C
Voc coefficient β−0.306 %/°C
Isc coefficient α+0.055 %/°C
Operating cell temperatureNOCT 43.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
395 W297.3 W29.2 V × 10.18 A78.2 W99%
400 W301.2 W29.3 V × 10.28 A79 W99%
405 W304.9 W29.4 V × 10.37 A79.9 W99%
410 W308.6 W29.5 V × 10.46 A81.1 W99%
415 W311.7 W29.6 V × 10.53 A81.8 W99%
440 W330.9 W31.6 V × 10.47 A85.8 W97%
445 W334.8 W31.7 V × 10.56 A86.7 W97%
450 W338.7 W31.8 V × 10.65 A87.6 W97%
455 W342 W31.9 V × 10.72 A88.6 W97%
460 W346.4 W32.1 V × 10.79 A89.7 W97%
485 W370.1 W35.37 V × 10.46 A93.2 W96%
490 W373.8 W35.51 V × 10.53 A94.2 W96%
495 W377.6 W35.65 V × 10.59 A95.1 W96%
500 W381.4 W35.7 V × 10.68 A96.1 W96%
505 W385.2 W35.84 V × 10.75 A97 W96%
530 W400.1 W38 V × 10.53 A102.8 W97%
535 W404.2 W38.1 V × 10.61 A103.8 W97%
540 W407.3 W38.1 V × 10.69 A104.8 W97%
545 W411 W38.2 V × 10.76 A105.8 W97%
550 W415.2 W38.3 V × 10.84 A106.8 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
44.4 V
Voc when cold
per panel
27.3 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V44.4 / 27.3 V✗ Not a match: module voltage below MPPT range1.21
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V44.4 / 27.3 V⚠ Works; below MPPT at peak heat0.59
Enphase IQ8M-72-2-US260–460 W60 V30–45 V44.4 / 27.3 V⚠ Works; below MPPT at peak heat1.42
Enphase IQ8A-72-2-US295–500 W60 V32–45 V44.4 / 27.3 V⚠ Works; below MPPT at peak heat1.32
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677111,5646.08
Palmdale1,83584412,6626.69
Chula Vista1,69678011,7026.11
Huntington Beach1,64375611,3375.89
Riverside1,69678011,7026.21
Santa Clarita1,72479311,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 460 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASoCal permits (series)
PEIMAR DR10H460M460 W≈21.5%−0.35541.514.01—
REC Group REC460AA Pure-RX460 W≈22.8%−0.24865.38.8833
Aptos Solar DNA-120-MF10-460W460 W≈21.3%−0.36341.71422
Canadian Solar CS6.1-54TM-460H460 W≥22.5%−0.30839.314.699
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the PEIMAR DR10H460M?

Calculated from the panel area (2.25 m²): about 21.5% for the 460 W class. 460 W over 2.25 m² equals about 204 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 771 kWh per year per 460 W panel in Los Angeles and about 844 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.355 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 44.4 V, Vmp at 74 °C cell = 27.3 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Aptos Solar — datasheet Legacy Products.
  3. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).