Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
350 W
260.5 W
31.41 V × 8.29 A
66 W
94%
360 W
266.2 W
31.98 V × 8.33 A
67.5 W
94%
370 W
274 W
32.73 V × 8.37 A
69.5 W
94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Electrical & strength ratings
Max system voltage1,000 V
Max series fuse25 A
Module temperature−40 °F to +185 °F−40 °C to +85 °C
Hail35 mm (1.38 in)
Power tolerance+10 / −0 W
Certifications
CEC PV Module List (Oct 7, 2026) · Panasonic datasheet
UL 61730IEC 61215IEC 61701IEC 62716IEC 62804IEC 62790IEC 62852
UL 61730CEC listing
IEC 61215datasheet
IEC 61701datasheet
IEC 62716datasheet
IEC 62804datasheet
IEC 62790datasheet
IEC 62852datasheet
Warranty & degradation
Panasonic datasheet · Cali-Graf calculation
Year 1≥ 98%
Then≤ 0.5% / year
Year 10≥ 93.5%calculated from warranty terms
Year 25≥ 86%
Inverter compatibility & string sizing
Panasonic datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43 V
Voc when cold
per panel
27.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–13
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–13
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–13
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
9–11
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8PLUS-72-2-US
235–440 W
60 V
29–45 V
43 / 27.7 V
⚠ Works; below MPPT at peak heat
1.24
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
43 / 27.7 V
✗ Not a match: module voltage below MPPT range
0.95
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
43 / 27.7 V
⚠ Works; below MPPT at peak heat
0.46
Enphase IQ8M-72-2-US
260–460 W
60 V
30–45 V
43 / 27.7 V
⚠ Works; below MPPT at peak heat
1.11
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
43 / 27.7 V
⚠ Works; below MPPT at peak heat
1.03
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
603
11,464
6.08
Palmdale
1,835
661
12,551
6.69
Chula Vista
1,696
611
11,601
6.11
Huntington Beach
1,643
591
11,238
5.89
Riverside
1,696
611
11,601
6.21
Santa Clarita
1,724
621
11,792
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 360 W panels
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
PVEL (product / brand)
SoCal permits (series)
Panasonic EVPV360PK
360 W
≥19.7%
−0.339
40.6
11.26
—
—
LONGi LR4-60HPB-360M
360 W
≈20.3%
−0.339
40.8
11.33
product 2021, 2022
193
REC Group REC360AA
360 W
≈21.4%
−0.279
44.1
10.23
brand 9× (2016–2025)
30
Trina Solar TSM-360DE06X.05(II)
360 W
≈19.8%
−0.339
44.8
10.3
product 2022
23
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
Questions & answers
How efficient is the Panasonic EVPV360PK?
The Panasonic datasheet guarantees at least 19.7% module efficiency for the 360 W class (up to 20.3% for 370 W). 360 W over 1.82 m² equals about 197 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 603 kWh per year per 360 W panel in Los Angeles and about 661 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.34 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.6% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
Panasonic — manufacturer datasheet “EVERVOLT® SOLAR MODULE PK BLACK SERIES 370PK/ 360PK”.
Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.