132 half-cut cells, N-type HJT. Power classes 390–410 W in the CEC list; datasheet covers 400–410 W.

CEC listed · Mar 13, 2023UL 61730N-type HJTInstalled in 4 SoCal permits
Power class
  • Power (STC)410 Wtolerance +10 / −0 W
  • Efficiency≥22.2%datasheet minimum
  • %/°C Pmax−0.26CEC test: −0.256
  • Degradation / yr0.25%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Panasonic datasheet · 3 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
EVPV390HK390 W48.6010.1941.509.40≈21.1%371 WMar 13, 2023
EVPV400HK400 W48.8010.2542.109.51≥21.6%381 WMar 13, 2023
EVPV410HK410 W49.0010.3542.709.61≥22.2%391 WMar 13, 2023
≈ efficiency = Pmax ÷ panel area 1.85 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

Panasonic datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Panasonic datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.26 %/°C−0.256 %/°C
Voc coefficient β−0.24 %/°C−0.233 %/°C
Isc coefficient α—+0.034 %/°C
Vmp coefficient≈ −0.29 %/°C—
Operating cell temperatureNMOT 44 °CNOCT 45 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W288.2 W38.9 V × 7.41 A71.8 W92%
400 W296.2 W39.5 V × 7.5 A73.7 W92%
410 W303.2 W40 V × 7.58 A75.5 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Panasonic datasheet
UL 61730IEC 61215IEC 61701IEC 62716IEC 62804IEC 62790IEC 62852

Warranty & degradation

Panasonic datasheet · Cali-Graf calculation
85%89%92%96%100%051015202598% yr 195.75% yr 1092% yr 25years
  • Year 1≥ 98%
  • Then≤ 0.25% / year
  • Year 10≥ 95.75%calculated from warranty terms
  • Year 25≥ 92%

Inverter compatibility & string sizing

Panasonic datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.7 V
Voc when cold
per panel
36.6 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V51.7 / 36.6 V✓ Within range1.41
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V51.7 / 36.6 V✗ Not a match: module voltage below MPPT range1.08
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V51.7 / 36.6 V✓ Within range0.53
Enphase IQ8M-72-2-US260–460 W60 V30–45 V51.7 / 36.6 V✓ Within range1.26
Enphase IQ8A-72-2-US295–500 W60 V32–45 V51.7 / 36.6 V✓ Within range1.17
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67668711,6826.08
Palmdale1,83575212,7906.69
Chula Vista1,69669511,8216.11
Huntington Beach1,64367411,4525.89
Riverside1,69669511,8216.21
Santa Clarita1,72470712,0166.28
763Jan763Feb979Mar1,082Apr1,069May1,135Jun1,196Jul1,210Aug1,058Sep933Oct802Nov694DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Who installs EVPVxxxHK panels in SoCal

building permits
4
Permits naming this series
Mar 2023 – Oct 2023
1
Jurisdictions so far
LA County (unincorp.) (4)

Permits over time

1Mar ’232Apr0May0Jun0Jul0Aug0Sep1Octpermits per month
Only installer and ZIP level is shown — no homeowner names, street addresses or permit numbers. Permits from LA County (unincorp.) come without a contractor license, so they count toward totals but not toward installers. Counts grow as more permit portals are loaded.

Installed together with

building permits

Microinverters

Enphase IQ8M
3
Number of permits naming both this panel series and the product; 4 of 4 permits list other equipment.

Compare with similar 410 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Panasonic EVPV410HK410 W≥22.2%−0.2564910.35—4
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W≈20.9%−0.33745.3711.2product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC410AA Pure410 W≈22.9%−0.2564910.35brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Panasonic EVPV410HK?

The Panasonic datasheet guarantees at least 22.2% module efficiency for the 410 W class. 410 W over 1.85 m² equals about 222 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 687 kWh per year per 410 W panel in Los Angeles and about 752 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.26 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 13.5% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.7 V, Vmp at 74 °C cell = 36.6 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 51.7 V vs max input 60 V; Vmp when hot 36.6 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

How big and heavy is it?

71.7 × 40 × 1.18 in (1,821 × 1,016 × 30 mm), 45.2 lb (20.5 kg).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Panasonic — manufacturer datasheet “EVERVOLT® SOLAR MODULE BLACK SERIES 410HK/400HK The Panasonic Advantage”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Mar 2023 – Oct 2023). Equipment matched from permit descriptions by model number.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).