Cali-GrafCali-Graf
Solar panelOrb Energy

Orb Energy Orb375M72-15

72 cells. Power classes 345–450 W in the CEC list.

CEC listed · Dec 23, 2019UL 1703
Power class
  • Power (STC)375 WCEC nameplate
  • Efficiency≈19.8%calculated from area
  • %/°C Pmax−0.397CEC listing test
  • PTC / STC92%PTC 345 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Orb345M72-15345 W48.909.4239.948.64≈18.3%317 WDec 23, 2019
Orb350M72-15350 W49.009.5039.848.74≈18.5%321 WDec 23, 2019
Orb355M72-15355 W49.109.5840.148.84≈18.8%326 WDec 23, 2019
Orb360M72-15360 W49.209.6640.248.95≈19.0%331 WDec 23, 2019
Orb365M72-15365 W49.309.7440.349.05≈19.3%336 WDec 23, 2019
Orb370M72-15370 W49.409.8240.449.15≈19.6%340 WDec 23, 2019
Orb375M72-15375 W49.509.9040.549.25≈19.8%345 WDec 23, 2019
Orb380M72-15380 W49.609.9840.649.35≈20.1%350 WDec 23, 2019
Orb430M72-15430 W50.6010.9541.3610.40≈20.3%401 WSep 1, 2023
Orb435M72-15435 W50.7011.0541.6410.45≈20.5%406 WSep 1, 2023
Orb440M72-15440 W50.8011.1541.9110.50≈20.8%411 WSep 1, 2023
Orb445M72-15445 W50.9011.2542.1910.55≈21.0%415 WSep 1, 2023
Orb450M72-15450 W51.0011.3542.4610.60≈21.2%420 WSep 1, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.89 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.397 %/°C
Voc coefficient β−0.299 %/°C
Isc coefficient α+0.060 %/°C
Operating cell temperatureNOCT 45.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
345 W249.4 W36.48 V × 6.84 A64.7 W94%
350 W251.7 W36.39 V × 6.92 A65.3 W93%
355 W256.5 W36.66 V × 7 A66.5 W94%
360 W260.3 W36.76 V × 7.08 A67.5 W94%
365 W263.9 W36.85 V × 7.16 A68.4 W94%
370 W267.5 W36.94 V × 7.24 A69.4 W94%
375 W271.1 W37.03 V × 7.32 A70.3 W94%
380 W274.7 W37.12 V × 7.4 A71.2 W94%
430 W322.2 W38.01 V × 8.48 A84.3 W98%
435 W326 W38.26 V × 8.52 A85.3 W98%
440 W329.6 W38.51 V × 8.56 A86.3 W98%
445 W333.4 W38.77 V × 8.6 A87.3 W98%
450 W337.1 W39.02 V × 8.64 A88.3 W98%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 1703IEC 61215

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.9 V
Voc when cold
per panel
31.5 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V52.9 / 31.5 V✓ Within range1.29
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.9 / 31.5 V✗ Not a match: module voltage below MPPT range0.99
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.9 / 31.5 V✓ Within range0.48
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.9 / 31.5 V✓ Within range1.15
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.9 / 31.5 V⚠ Works; below MPPT at peak heat1.07
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662811,9426.08
Palmdale1,83568813,0746.69
Chula Vista1,69663612,0846.11
Huntington Beach1,64361611,7065.89
Riverside1,69663612,0846.21
Santa Clarita1,72464612,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 375 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Orb Energy Orb375M72-15375 W≈19.8%−0.39749.59.9——
Qcells Q.PEAK DUO BLK ML-G10+ 380380 W≈19.4%−0.36245.1611.01product 2022, 2023221
LONGi LR4-60HPB-370M370 W≈20.9%−0.33941.211.5product 2021, 2022193
REC Group REC380AA Pure380 W≈21.2%−0.25648.410.17brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Orb Energy Orb375M72-15?

Calculated from the panel area (1.89 m²): about 19.8% for the 375 W class. 375 W over 1.89 m² equals about 198 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 628 kWh per year per 375 W panel in Los Angeles and about 688 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.397 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.9 V, Vmp at 74 °C cell = 31.5 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 52.9 V vs max input 60 V; Vmp when hot 31.5 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).