132 cells, bifacial. Power classes 690–720 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| NKM690N-132BDG12 | 690 W | 48.08 | 18.26 | 40.17 | 17.18 | ≈22.2% | 650 W | Jul 21, 2025 |
| NKM695N-132BDG12 | 695 W | 48.24 | 18.33 | 40.29 | 17.25 | ≈22.3% | 655 W | Jul 21, 2025 |
| NKM700N-132BDG12 | 700 W | 48.40 | 18.40 | 40.41 | 17.33 | ≈22.5% | 660 W | Jul 21, 2025 |
| NKM705N-132BDG12 | 705 W | 48.56 | 18.46 | 40.52 | 17.40 | ≈22.7% | 664 W | Jul 21, 2025 |
| NKM710N-132BDG12 | 710 W | 48.73 | 18.53 | 40.64 | 17.47 | ≈22.8% | 669 W | Jul 21, 2025 |
| NKM715N-132BDG12 | 715 W | 48.88 | 18.60 | 40.76 | 17.54 | ≈23.0% | 674 W | Jul 21, 2025 |
| NKM720N-132BDG12 | 720 W | 49.04 | 18.67 | 40.88 | 17.61 | ≈23.2% | 679 W | Jul 21, 2025 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.297 %/°C |
| Voc coefficient β | −0.256 %/°C |
| Isc coefficient α | +0.046 %/°C |
| Operating cell temperature | NOCT 46 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 690 W | 547.8 W | 45.62 V × 12.01 A | — | — |
| 695 W | 580.8 W | 45.8 V × 12.68 A | — | — |
| 700 W | 585.5 W | 45.96 V × 12.74 A | — | — |
| 705 W | 590.5 W | 46.13 V × 12.8 A | — | — |
| 710 W | 595.4 W | 46.3 V × 12.86 A | — | — |
| 715 W | 600.3 W | 46.46 V × 12.92 A | — | — |
| 720 W | 605.1 W | 46.62 V × 12.98 A | — | — |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 1,182 | 11,816 | 6.08 |
| Palmdale | 1,835 | 1,294 | 12,937 | 6.69 |
| Chula Vista | 1,696 | 1,196 | 11,957 | 6.11 |
| Huntington Beach | 1,643 | 1,158 | 11,583 | 5.89 |
| Riverside | 1,696 | 1,196 | 11,957 | 6.21 |
| Santa Clarita | 1,724 | 1,215 | 12,154 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) |
|---|---|---|---|---|---|---|
| Nuuko Solar NKM705N-132BDG12 | 705 W | ≈22.7% | −0.297 | 48.56 | 18.46 | — |
| Canadian Solar CS7N-705TB-AG | 705 W | ≈22.7% | −0.285 | 48.1 | 18.54 | product 2024 |
| Phono Solar PS705M13GFH-22/WNH | 705 W | ≈22.9% | −0.291 | 48.8 | 18.14 | brand 9× (2016–2026) |
| Waaree BiN-03-705 | 705 W | ≥22.7% | −0.302 | 48.3 | 18.36 | brand 5× (2022–2026) |
Calculated from the panel area (3.11 m²): about 22.7% for the 705 W class. 705 W over 3.11 m² equals about 227 W per square meter.
PVWatts v8 with typical-year weather gives about 1,182 kWh per year per 705 W panel in Los Angeles and about 1,294 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.297 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.4 V, Vmp at 74 °C cell = 33.7 V). Final design must follow the inverter manual and NEC 690.7.
Yes. Rear gain depends on mounting height and ground reflectance.