108 half-cut cells, bifacial. Power classes 490–520 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| NKM490N-108BDR12 | 490 W | 40.56 | 15.34 | 33.75 | 14.52 | ≈22.1% | 461 W | Sep 1, 2026 |
| NKM495N-108BDR12 | 495 W | 40.72 | 15.43 | 33.88 | 14.61 | ≈22.3% | 466 W | Sep 1, 2026 |
| NKM500N-108BDR12 | 500 W | 40.89 | 15.52 | 34.02 | 14.70 | ≈22.5% | 471 W | Sep 1, 2026 |
| NKM505N-108BDR12 | 505 W | 41.05 | 15.61 | 34.15 | 14.79 | ≈22.7% | 476 W | Sep 1, 2026 |
| NKM510N-108BDR12 | 510 W | 41.21 | 15.70 | 34.29 | 14.87 | ≈23.0% | 481 W | Sep 1, 2026 |
| NKM515N-108BDR12 | 515 W | 41.37 | 15.79 | 34.42 | 14.96 | ≈23.2% | 486 W | Sep 1, 2026 |
| NKM520N-108BDR12 | 520 W | 41.53 | 15.88 | 34.56 | 15.05 | ≈23.4% | 490 W | Sep 1, 2026 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.298 %/°C |
| Voc coefficient β | −0.252 %/°C |
| Isc coefficient α | +0.046 %/°C |
| Operating cell temperature | NOCT 46.1 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 490 W | 367.9 W | 31.39 V × 11.72 A | 94.7 W | 97% |
| 495 W | 371.6 W | 31.51 V × 11.79 A | 95.7 W | 97% |
| 500 W | 375.5 W | 31.64 V × 11.87 A | 96.7 W | 97% |
| 505 W | 379.2 W | 31.76 V × 11.94 A | 97.6 W | 97% |
| 510 W | 382.8 W | 31.89 V × 12 A | 98.6 W | 97% |
| 515 W | 386.6 W | 32.01 V × 12.08 A | 99.5 W | 97% |
| 520 W | 390.5 W | 32.14 V × 12.15 A | 100.5 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 3–13 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–13 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–13 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 9–11 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 43.4 / 28.4 V | ✗ Not a match: module voltage below MPPT range | 1.33 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 43.4 / 28.4 V | ✓ Within range | 0.65 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 846 | 11,849 | 6.08 |
| Palmdale | 1,835 | 927 | 12,973 | 6.69 |
| Chula Vista | 1,696 | 856 | 11,991 | 6.11 |
| Huntington Beach | 1,643 | 830 | 11,616 | 5.89 |
| Riverside | 1,696 | 856 | 11,991 | 6.21 |
| Santa Clarita | 1,724 | 871 | 12,189 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | SoCal permits (series) |
|---|---|---|---|---|---|---|
| Nuuko Solar NKM505N-108BDR12 | 505 W | ≈22.7% | −0.298 | 41.05 | 15.61 | — |
| SEG Solar SEG-505-BTD-BG | 505 W | ≈25.9% | −0.290 | 40.3 | 15.95 | 8 |
| Qcells Q.PEAK DUO XL-G10.d 505 | 505 W | ≈21.8% | −0.340 | 53.78 | 11.39 | 6 |
| AXITEC AC-530MH/144V | 530 W | ≥20.5% | −0.366 | 49.3 | 13.72 | 1 |
Calculated from the panel area (2.22 m²): about 22.7% for the 505 W class. 505 W over 2.22 m² equals about 227 W per square meter.
PVWatts v8 with typical-year weather gives about 846 kWh per year per 505 W panel in Los Angeles and about 927 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.298 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.4 V, Vmp at 74 °C cell = 28.4 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 43.4 V vs max input 60 V; Vmp when hot 28.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.