Cali-GrafCali-Graf
Solar panelNuuko Solar

Nuuko Solar NKM420N-108BDM10

108 half-cut cells, bifacial. Power classes 405–440 W in the CEC list.

CEC listed · Sep 1, 2026UL 61730Bifacial
Power class
  • Power (STC)420 WCEC nameplate
  • Efficiency≈21.5%calculated from area
  • %/°C Pmax−0.302CEC listing test
  • PTC / STC94.1%PTC 395 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
NKM405N-108BDM10405 W37.3013.7731.3012.94≈20.8%381 WSep 1, 2026
NKM410N-108BDM10410 W37.5013.8431.5013.02≈21.0%386 WSep 1, 2026
NKM415N-108BDM10415 W37.7013.9131.7013.09≈21.3%390 WSep 1, 2026
NKM420N-108BDM10420 W37.9013.9831.9013.17≈21.5%395 WSep 1, 2026
NKM425N-108BDM10425 W38.1014.0532.1013.24≈21.8%400 WSep 1, 2026
NKM430N-108BDM10430 W38.3014.1232.3013.31≈22.1%405 WSep 1, 2026
NKM435N-108BDM10435 W38.4014.1832.5013.38≈22.3%410 WSep 1, 2026
NKM440N-108BDM10440 W38.6014.2532.7013.46≈22.6%414 WSep 1, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.302 %/°C
Voc coefficient β−0.252 %/°C
Isc coefficient α+0.046 %/°C
Operating cell temperatureNOCT 45.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
405 W304.5 W29.61 V × 10.29 A78.3 W97%
410 W308.4 W29.79 V × 10.35 A79.3 W97%
415 W312 W29.98 V × 10.41 A80.2 W97%
420 W315.9 W30.17 V × 10.47 A81.2 W97%
425 W319.6 W30.36 V × 10.53 A82.2 W97%
430 W323.3 W30.55 V × 10.58 A83.1 W97%
435 W327 W30.74 V × 10.64 A84.1 W97%
440 W331 W30.93 V × 10.7 A85.1 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
40.1 V
Voc when cold
per panel
26.5 V
Vmp when hot
per panel
14
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–14
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–14
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–14
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–12

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V40.1 / 26.5 V⚠ Works; below MPPT at peak heat1.45
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V40.1 / 26.5 V✗ Not a match: module voltage below MPPT range1.11
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V40.1 / 26.5 V⚠ Works; below MPPT at peak heat0.54
Enphase IQ8M-72-2-US260–460 W60 V30–45 V40.1 / 26.5 V⚠ Works; below MPPT at peak heat1.29
Enphase IQ8A-72-2-US295–500 W60 V32–45 V40.1 / 26.5 V✗ Not a match: module voltage below MPPT range1.2
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67670411,9676.08
Palmdale1,83577113,1026.69
Chula Vista1,69671212,1096.11
Huntington Beach1,64369011,7315.89
Riverside1,69671212,1096.21
Santa Clarita1,72472412,3096.28
781Jan782Feb1,003Mar1,108Apr1,095May1,163Jun1,225Jul1,240Aug1,084Sep956Oct822Nov711DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 420 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Nuuko Solar NKM420N-108BDM10420 W≈21.5%−0.30237.913.98——
Qcells Q.PEAK DUO BLK ML-G10+ 415415 W≈21.1%−0.33745.4111.23product 2022, 2023221
LONGi LR5-54HABB-415M415 W≈21.8%−0.34237.7713.94brand 9× (2017–2026)64
Canadian Solar CS3N-420MS420 W≥20.7%−0.33245.311.74product 202346
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Nuuko Solar NKM420N-108BDM10?

Calculated from the panel area (1.95 m²): about 21.5% for the 420 W class. 420 W over 1.95 m² equals about 215 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 704 kWh per year per 420 W panel in Los Angeles and about 771 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.302 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–14 panels per string (Voc at 2 °C = 40.1 V, Vmp at 74 °C cell = 26.5 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  3. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).