Cali-GrafCali-Graf
Solar panelNexora Solar

Nexora Solar NEXO-E-NTDD-Serise 715

132 half-cut cells, bifacial, glass (dual-glass module). Power classes 695–740 W in the CEC list.

CEC listed · Aug 21, 2026UL 61730Bifacial
Power class
  • Power (STC)715 WCEC nameplate
  • Efficiency≈23.1%calculated from area
  • %/°C Pmax−0.262CEC listing test
  • PTC / STC95.6%PTC 684 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
NEXO-E-NTDD-Serise 695695 W48.1018.2340.3017.25≈22.4%664 WAug 21, 2026
NEXO-E-NTDD-Serise 700700 W48.3018.2740.5017.29≈22.6%669 WAug 21, 2026
NEXO-E-NTDD-Serise 705705 W48.5018.3140.7017.33≈22.7%674 WAug 21, 2026
NEXO-E-NTDD-Serise 710710 W48.7018.3540.9017.37≈22.9%679 WAug 21, 2026
NEXO-E-NTDD-Serise 715715 W48.9018.3941.1017.40≈23.1%684 WAug 21, 2026
NEXO-E-NTDD-Serise 720720 W49.1018.4341.3017.44≈23.2%688 WAug 21, 2026
NEXO-E-NTDD-Serise 725725 W49.3018.4741.5017.47≈23.4%693 WAug 21, 2026
NEXO-E-NTDD-Serise 730730 W49.5018.5141.7017.51≈23.5%698 WAug 21, 2026
NEXO-E-NTDD-Serise 735735 W49.7018.5541.9017.55≈23.7%703 WAug 21, 2026
NEXO-E-NTDD-Serise 740740 W49.9018.9542.1017.58≈23.9%708 WAug 21, 2026
≈ efficiency = Pmax ÷ CEC-listed area 3.1 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.262 %/°C
Voc coefficient β−0.225 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 43.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
695 W530.4 W38.8 V × 13.67 A133.4 W96%
700 W534.3 W39 V × 13.7 A134.5 W96%
705 W538.6 W39.2 V × 13.74 A135.5 W96%
710 W542.5 W39.4 V × 13.77 A136.2 W96%
715 W546.1 W39.6 V × 13.79 A137.3 W96%
720 W550 W39.8 V × 13.82 A138.3 W96%
725 W554 W40 V × 13.85 A139 W96%
730 W558 W40.2 V × 13.88 A140.1 W96%
735 W562 W40.4 V × 13.91 A141.1 W96%
740 W565.6 W40.6 V × 13.93 A141.8 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.4 V
Voc when cold
per panel
34.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,19811,9836.08
Palmdale1,8351,31213,1206.69
Chula Vista1,6961,21312,1266.11
Huntington Beach1,6431,17511,7475.89
Riverside1,6961,21312,1266.21
Santa Clarita1,7241,23312,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 715 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Nexora Solar NEXO-E-NTDD-Serise 715715 W≈23.1%−0.26248.918.39—
Canadian Solar CS7N-715TB-AG715 W≈23%−0.28548.518.64product 2024
Phono Solar PS715M13GFH-22/WNH715 W≈23.2%−0.29149.218.22brand 9× (2016–2026)
Waaree BiN-03-710710 W≥22.9%−0.30248.4518.4brand 5× (2022–2026)
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Nexora Solar NEXO-E-NTDD-Serise 715?

Calculated from the panel area (3.1 m²): about 23.1% for the 715 W class. 715 W over 3.1 m² equals about 231 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,198 kWh per year per 715 W panel in Los Angeles and about 1,312 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.262 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 13.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.4 V, Vmp at 74 °C cell = 34.9 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — datasheet New N-type Bifacial Module TOPBiHiKu7 CS7N-725|730|735|740|745|750TB-AG.
  3. Waaree — datasheet ELITE SERIES BiN-03.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).