Solar panelNew East Solar Energy (Cambodia)

New East Solar Energy (Cambodia) NESE370-72MV

72 cells. Power classes 355–390 W in the CEC list.

CEC listed · May 1, 2020UL 61730
Power class
  • Power (STC)370 WCEC nameplate
  • Efficiency≈19.3%calculated from area
  • %/°C Pmax−0.343CEC listing test
  • PTC / STC93.5%PTC 346 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 8 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
NESE355-72MV355 W48.109.5939.309.04≈18.5%332 WMay 1, 2020
NESE360-72MV360 W48.209.6939.409.15≈18.8%336 WMay 1, 2020
NESE365-72MV365 W48.309.7839.509.24≈19.0%341 WMay 1, 2020
NESE370-72MV370 W48.409.8739.609.34≈19.3%346 WMay 1, 2020
NESE375-72MV375 W48.609.9939.709.45≈19.5%351 WMay 1, 2020
NESE380-72MV380 W48.7010.0839.809.55≈19.8%356 WMay 1, 2020
NESE385-72MV385 W48.8010.1839.909.65≈20.1%360 WMay 1, 2020
NESE390-72MV390 W48.9010.2840.009.75≈20.3%365 WMay 1, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.92 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.343 %/°C
Voc coefficient β−0.262 %/°C
Isc coefficient α+0.041 %/°C
Operating cell temperatureNOCT 44.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
355 W264.7 W37.35 V × 7.09 A68.7 W97%
360 W268.7 W37.44 V × 7.18 A69.7 W97%
365 W272 W37.54 V × 7.25 A70.6 W97%
370 W275.6 W37.63 V × 7.32 A71.6 W97%
375 W279.6 W37.73 V × 7.41 A72.6 W97%
380 W283.2 W37.82 V × 7.49 A73.5 W97%
385 W286.9 W37.92 V × 7.57 A74.5 W97%
390 W290.6 W38.01 V × 7.65 A75.5 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.3 V
Voc when cold
per panel
32.1 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V51.3 / 32.1 V✓ Within range1.28
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V51.3 / 32.1 V✗ Not a match: module voltage below MPPT range0.97
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V51.3 / 32.1 V✓ Within range0.47
Enphase IQ8M-72-2-US260–460 W60 V30–45 V51.3 / 32.1 V✓ Within range1.14
Enphase IQ8A-72-2-US295–500 W60 V32–45 V51.3 / 32.1 V✓ Within range1.06
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662011,7826.08
Palmdale1,83567912,9006.69
Chula Vista1,69662811,9236.11
Huntington Beach1,64360811,5505.89
Riverside1,69662811,9236.21
Santa Clarita1,72463812,1206.28
769Jan770Feb988Mar1,091Apr1,078May1,145Jun1,206Jul1,220Aug1,067Sep941Oct809Nov700DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 370 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · Canadian Solar datasheet · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
New East Solar Energy (Cambodia) NESE370-72MV370 W≈19.3%−0.34348.49.87——
LONGi LR4-60HPB-370M370 W≈20.9%−0.33941.211.5product 2021, 2022193
Canadian Solar CS3N-375MS {Blk}375 W≈19%−0.34243.511.2product 202346
REC Group REC370AA370 W≈21.9%−0.25844.110.55brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the New East Solar Energy (Cambodia) NESE370-72MV?

Calculated from the panel area (1.92 m²): about 19.3% for the 370 W class. 370 W over 1.92 m² equals about 193 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.343 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.3 V, Vmp at 74 °C cell = 32.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 51.3 V vs max input 60 V; Vmp when hot 32.1 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  4. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  5. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  6. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  7. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).