Cali-GrafCali-Graf
Solar panelNew East Solar Energy (Cambodia)

New East Solar Energy (Cambodia) NESE620-66THB-G12R

132 half-cut cells. Power classes 600–640 W in the CEC list.

CEC listed · Oct 21, 2025UL 61730
Power class
  • Power (STC)620 WCEC nameplate
  • Efficiency≈23.0%calculated from area
  • %/°C Pmax−0.279CEC listing test
  • PTC / STC95.4%PTC 591 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 9 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
NESE600-66THB-G12R600 W48.1015.8540.2014.93≈22.3%572 WOct 21, 2025
NESE605-66THB-G12R605 W48.3015.9040.4014.98≈22.5%577 WOct 21, 2025
NESE610-66THB-G12R610 W48.5015.9540.6015.03≈22.7%582 WOct 21, 2025
NESE615-66THB-G12R615 W48.7016.0040.8015.08≈22.9%586 WOct 21, 2025
NESE620-66THB-G12R620 W48.9016.0541.0015.13≈23.0%591 WOct 21, 2025
NESE625-66THB-G12R625 W49.1016.0941.2015.17≈23.2%596 WOct 21, 2025
NESE630-66THB-G12R630 W49.3016.1441.4015.22≈23.4%601 WOct 21, 2025
NESE635-66THB-G12R635 W49.5016.1941.6015.27≈23.6%606 WOct 21, 2025
NESE640-66THB-G12R640 W49.7016.2441.8015.32≈23.8%611 WOct 21, 2025
≈ efficiency = Pmax ÷ CEC-listed area 2.69 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.279 %/°C
Voc coefficient β−0.232 %/°C
Isc coefficient α+0.041 %/°C
Operating cell temperatureNOCT 43.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
600 W462.3 W39.37 V × 11.74 A116.4 W97%
605 W463.8 W39.37 V × 11.78 A116.8 W96%
610 W467.7 W39.56 V × 11.82 A117.7 W97%
615 W471.6 W39.76 V × 11.86 A118.7 W97%
620 W475.4 W39.95 V × 11.9 A119.7 W97%
625 W479 W40.15 V × 11.93 A120.6 W96%
630 W482.9 W40.34 V × 11.97 A121.6 W96%
635 W486.9 W40.54 V × 12.01 A122.6 W97%
640 W490.8 W40.73 V × 12.05 A123.6 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.5 V
Voc when cold
per panel
34.6 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,03911,4306.08
Palmdale1,8351,13812,5156.69
Chula Vista1,6961,05211,5676.11
Huntington Beach1,6431,01911,2055.89
Riverside1,6961,05211,5676.21
Santa Clarita1,7241,06911,7586.28
746Jan747Feb958Mar1,058Apr1,046May1,111Jun1,170Jul1,184Aug1,035Sep913Oct785Nov679DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 620 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
New East Solar Energy (Cambodia) NESE620-66THB-G12R620 W≈23%−0.27948.916.05—
ZNShine Solar ZXM7-UHLDD144-615/N615 W≈24%−0.28152.914.72product 2024, 2025, 2026
JinkoSolar JKM620N-66HL4M-BDV620 W≈23%−0.29949.0816.08product 2025
Waaree BiN-21-620620 W≥22.9%−0.28849.116.02product 2026
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the New East Solar Energy (Cambodia) NESE620-66THB-G12R?

Calculated from the panel area (2.69 m²): about 23% for the 620 W class. 620 W over 2.69 m² equals about 230 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,039 kWh per year per 620 W panel in Los Angeles and about 1,138 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.279 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 14.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.5 V, Vmp at 74 °C cell = 34.6 V). Final design must follow the inverter manual and NEC 690.7.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  3. Waaree — datasheet ELITE-R-SERIES-BiN-21-600-635-WEL-EPD-600-635-132-BiN-HC.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  8. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).