Cali-GrafCali-Graf
Solar panelMitrex

Mitrex M325-RF041F

72 cells. Power classes 295–355 W in the CEC list.

CEC listed · Dec 21, 2022UL 61730
Power class
  • Power (STC)325 WCEC nameplate
  • Efficiency≈16.2%calculated from area
  • %/°C Pmax−0.364CEC listing test
  • PTC / STC91%PTC 296 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
M295-RF041F295 W48.407.6440.507.28≈14.8%268 WDec 21, 2022
M300-RF041F300 W48.407.7740.507.41≈15.0%273 WDec 21, 2022
M305-RF041F305 W48.507.9040.607.51≈15.2%277 WDec 21, 2022
M310-RF041F310 W48.508.0340.607.64≈15.5%282 WDec 21, 2022
M315-RF041F315 W48.608.1640.707.74≈15.8%287 WDec 21, 2022
M320-RF041F320 W48.608.2940.707.86≈16.0%291 WDec 21, 2022
M325-RF041F325 W48.708.4240.807.98≈16.2%296 WDec 21, 2022
M330-RF041F330 W48.708.5540.808.09≈16.5%300 WDec 21, 2022
M335-RF041F335 W48.808.6840.908.19≈16.8%305 WDec 21, 2022
M340-RF041F340 W48.808.8140.908.31≈17.0%311 WDec 21, 2022
M345-RF041F345 W48.908.9441.008.41≈17.2%316 WDec 21, 2022
M350-RF041F350 W48.909.0741.008.54≈17.5%320 WDec 21, 2022
M355-RF041F355 W49.009.2041.108.64≈17.8%325 WDec 21, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.364 %/°C
Voc coefficient β−0.272 %/°C
Isc coefficient α+0.032 %/°C
Operating cell temperatureNOCT 49 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
295 W220 W36.74 V × 5.99 A58.2 W99%
300 W223.9 W36.74 V × 6.09 A59.3 W99%
305 W227.5 W36.83 V × 6.18 A60.2 W99%
310 W231.4 W36.83 V × 6.28 A61.3 W99%
315 W235 W36.92 V × 6.37 A62.2 W99%
320 W242.9 W36.71 V × 6.62 A64.6 W101%
325 W247.2 W36.8 V × 6.72 A65.7 W101%
330 W250.6 W36.8 V × 6.81 A66.6 W101%
335 W254.3 W36.89 V × 6.89 A67.6 W101%
340 W247.5 W36.84 V × 6.72 A65.4 W96%
345 W251.1 W36.93 V × 6.8 A66.4 W96%
350 W255 W36.93 V × 6.91 A67.4 W96%
355 W258.6 W37.02 V × 6.99 A68.4 W96%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.7 V
Voc when cold
per panel
32.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V51.7 / 32.9 V✓ Within range1.12
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V51.7 / 32.9 V✗ Not a match: module voltage below MPPT range0.86
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V51.7 / 32.9 V✓ Within range0.42
Enphase IQ8M-72-2-US260–460 W60 V30–45 V51.7 / 32.9 V✓ Within range1
Enphase IQ8A-72-2-US295–500 W60 V32–45 V51.7 / 32.9 V✓ Within range0.93
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67654511,9836.08
Palmdale1,83559613,1206.69
Chula Vista1,69655112,1266.11
Huntington Beach1,64353411,7475.89
Riverside1,69655112,1266.21
Santa Clarita1,72456012,3276.28
782Jan783Feb1,005Mar1,110Apr1,096May1,165Jun1,227Jul1,241Aug1,085Sep957Oct823Nov712DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 325 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
Mitrex M325-RF041F325 W≈16.2%−0.36448.78.42————
JinkoSolar JKM325M-60HBL325 W≈19.3%−0.40741.110.266.3 × 39.4 in10 / 25 yrbrand 12× (2014–2026)45
Qcells Q.PEAK DUO-G8+ 330330 W≈18.4%−0.34339.7110.5268.5 × 40.6 in25 / 25 yrproduct 202220
LG Electronics LG325N1C-N5325 W≈18.8%−0.34240.910.5766.9 × 40 in25 / 25 yrproduct 20215
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Mitrex M325-RF041F?

Calculated from the panel area (2 m²): about 16.2% for the 325 W class. 325 W over 2 m² equals about 162 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 545 kWh per year per 325 W panel in Los Angeles and about 596 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.364 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.7 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 51.7 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO-G8+ 345-360 EN ENDURING HIGH”.
  5. LG Electronics — datasheet Specification Sheet.
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).