Solar panelMission Solar Energy

Mission Solar Energy TXS6-365120BB

120 half-cut cells, PERC. Power classes 350–375 W in the CEC list.

CEC listed · Jun 11, 2021UL 6173025-yr product + 25-yr performance warrantyPERCSeen in 1 SoCal permit
Power class
  • Power (STC)365 WCEC nameplate
  • Efficiency≈20.0%calculated from area
  • %/°C Pmax−0.334CEC listing test
  • Degradation / yr0.5%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
TXS6-350120BB350 W40.2011.0433.4010.48≈19.2%327 WJun 11, 2021
TXS6-355120BB355 W40.4011.1433.6010.57≈19.5%331 WJun 11, 2021
TXS6-360120BB360 W40.6011.2433.8010.66≈19.8%336 WJun 11, 2021
TXS6-365120BB365 W40.8011.3334.0010.74≈20.0%341 WJun 11, 2021
TXS6-370120BB370 W41.0011.4234.2010.82≈20.3%346 WJun 11, 2021
TXS6-375120BB375 W41.2011.5134.4010.91≈20.6%350 WJun 11, 2021
≈ efficiency = Pmax ÷ panel area 1.822 m² (datasheet size).

Build & dimensions

Mission Solar Energy datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Mission Solar Energy datasheet · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ—−0.334 %/°C
Voc coefficient β—−0.263 %/°C
Isc coefficient α+0.05 %/°C+0.048 %/°C
Vmp coefficient≈ −0.38 %/°C—
Operating cell temperatureNMOT 44 ± 2 °CNOCT 45.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
350 W259.9 W31.59 V × 8.23 A65 W93%
355 W263.7 W31.78 V × 8.3 A65.9 W93%
360 W267.5 W31.97 V × 8.37 A66.9 W93%
365 W271.1 W32.16 V × 8.43 A67.8 W93%
370 W274.8 W32.34 V × 8.49 A68.7 W93%
375 W278.7 W32.53 V × 8.57 A69.7 W93%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Mission Solar Energy datasheet
UL 61730IEC 61215IEC 61730Fire rating Type 1 (UL 61730)

Warranty & degradation

Mission Solar Energy datasheet

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2
PVEL Scorecards
Mission Solar Energy named Top Performer, 2024–2025
4
RETC PV Module Index
Mission Solar Energy recognized 2023–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Mission Solar Energy

YearRecognition
2023High Achievement in Performance (Module efficiency)
2024Test Category High Achiever
2025Performance High Achiever
2026Performance discipline high achiever (Iam, Lid); Quality discipline high achiever (BOM verification); Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.3 V
Voc when cold
per panel
27.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.3 / 27.7 V⚠ Works; below MPPT at peak heat1.26
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.3 / 27.7 V✗ Not a match: module voltage below MPPT range0.96
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.3 / 27.7 V⚠ Works; below MPPT at peak heat0.47
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.3 / 27.7 V⚠ Works; below MPPT at peak heat1.12
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.3 / 27.7 V⚠ Works; below MPPT at peak heat1.05
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67661211,6236.08
Palmdale1,83567012,7266.69
Chula Vista1,69661911,7626.11
Huntington Beach1,64360011,3945.89
Riverside1,69661911,7626.21
Santa Clarita1,72462911,9566.28
759Jan759Feb974Mar1,076Apr1,063May1,130Jun1,190Jul1,204Aug1,053Sep929Oct798Nov691DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 365 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Mission Solar Energy TXS6-365120BB365 W≈20%−0.33440.811.33brand 2×1
LONGi LR4-60HPB-365M365 W≈20.6%−0.3394111.41product 2021, 2022193
REC Group REC365AA365 W≈21.7%−0.27944.310.26brand 9× (2016–2025)30
Trina Solar TSM-365DE06X.05(II)365 W≈20.1%−0.3394510.35product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Mission Solar Energy

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

MSExxxSX9R · 4MSExxxSX5R · 2MSExxxHT0B · 1MSExxxSX6Z · 1TXS6-xxx144BB · 1MSExxxTS60 · 1

Questions & answers

How efficient is the Mission Solar Energy TXS6-365120BB?

Calculated from the panel area (1.82 m²): about 20% for the 365 W class. 365 W over 1.82 m² equals about 200 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 612 kWh per year per 365 W panel in Los Angeles and about 670 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.334 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.3 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance (manufacturer datasheet).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Mission Solar Energy was named a Top Performer in 2 Scorecards (2024–2025).

What fire rating does it have?

UL 61730 fire rating Type 1 per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Mission Solar Energy — manufacturer datasheet “120BB 365W HC Series mSolar 9BB Half-Cell Black”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2025.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.