Mission Solar Energy MSN12-655HP3T

132 half-cut cells. Power classes 635–680 W in the CEC list.

CEC listed · Dec 22, 2025UL 61730
Power class
  • Power (STC)655 WCEC nameplate
  • Efficiency≈21.3%calculated from area
  • %/°C Pmax−0.309CEC listing test
  • PTC / STC94.9%PTC 622 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 10 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
MSN12-635HP3T635 W44.6018.1137.1017.12≈20.6%602 WDec 22, 2025
MSN12-640HP3T640 W44.8018.1737.3017.17≈20.8%607 WDec 22, 2025
MSN12-645HP3T645 W45.0018.2237.5017.21≈20.9%612 WDec 22, 2025
MSN12-650HP3T650 W45.2018.2737.7017.25≈21.1%617 WDec 22, 2025
MSN12-655HP3T655 W45.4018.3237.9017.29≈21.3%622 WDec 22, 2025
MSN12-660HP3T660 W45.6018.3738.1017.33≈21.4%627 WDec 22, 2025
MSN12-665HP3T665 W45.8018.4238.3017.37≈21.6%632 WDec 22, 2025
MSN12-670HP3T670 W46.0018.4738.5017.42≈21.8%636 WDec 22, 2025
MSN12-675HP3T675 W46.2018.5238.7017.45≈21.9%641 WDec 22, 2025
MSN12-680HP3T680 W46.4018.5738.9017.49≈22.1%646 WDec 22, 2025
≈ efficiency = Pmax ÷ CEC-listed area 3.08 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.309 %/°C
Voc coefficient β−0.415 %/°C
Isc coefficient α+0.051 %/°C
Operating cell temperatureNOCT 42.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
635 W466.4 W34.78 V × 13.41 A120.9 W95%
640 W470.3 W34.96 V × 13.45 A121.9 W95%
645 W473.9 W35.15 V × 13.48 A122.8 W95%
650 W477.5 W35.34 V × 13.51 A123.8 W95%
655 W481.2 W35.53 V × 13.54 A124.7 W95%
660 W484.8 W35.71 V × 13.58 A125.6 W95%
665 W488.5 W35.9 V × 13.61 A126.6 W95%
670 W492.5 W36.09 V × 13.65 A127.6 W95%
675 W495.9 W36.28 V × 13.67 A128.5 W95%
680 W499.6 W36.46 V × 13.7 A129.5 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2
PVEL Scorecards
Mission Solar Energy named Top Performer, 2024–2025
4
RETC PV Module Index
Mission Solar Energy recognized 2023–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Mission Solar Energy

YearRecognition
2023High Achievement in Performance (Module efficiency)
2024Test Category High Achiever
2025Performance High Achiever
2026Performance discipline high achiever (Iam, Lid); Quality discipline high achiever (BOM verification); Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
49.7 V
Voc when cold
per panel
31.2 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

No microinverter in the reference set lists this power class in its recommended module power range.
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6761,09812,0766.08
Palmdale1,8351,20213,2216.69
Chula Vista1,6961,11112,2206.11
Huntington Beach1,6431,07611,8385.89
Riverside1,6961,11112,2206.21
Santa Clarita1,7241,12912,4216.28
788Jan789Feb1,012Mar1,118Apr1,105May1,174Jun1,236Jul1,251Aug1,094Sep965Oct829Nov718DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 655 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)
Mission Solar Energy MSN12-655HP3T655 W≈21.3%−0.30945.418.32brand 2×
Canadian Solar CS7N-655MB-AG655 W≈21.3%−0.39045.218.43product 2024
Hyundai Energy Solutions HiN-T650NJ650 W≈23.5%−0.27356.714.51brand 5× (2017–2025)
JinkoSolar JKM650N-66HL4M-BDV650 W≈24.1%−0.29950.2816.44product 2025
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Mission Solar Energy

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

MSExxxSX9R · 4MSExxxSX5R · 2MSExxxHT0B · 1MSExxxSX6Z · 1TXS6-xxx120BB · 1TXS6-xxx144BB · 1

Questions & answers

How efficient is the Mission Solar Energy MSN12-655HP3T?

Calculated from the panel area (3.08 m²): about 21.3% for the 655 W class. 655 W over 3.08 m² equals about 213 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 1,098 kWh per year per 655 W panel in Los Angeles and about 1,202 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.309 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 16% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 49.7 V, Vmp at 74 °C cell = 31.2 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Mission Solar Energy was named a Top Performer in 2 Scorecards (2024–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Hyundai Energy Solutions — datasheet [US] NJ(HiN) Series (N TOPCon Bifacial) 640~645W.
  3. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR PRODUCT.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2025.
  5. RETC — PV Module Index reports 2023–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).