Cali-GrafCali-Graf
Solar panelMission Solar Energy

Mission Solar Energy MSE345SX5K

60 cells. Power classes 335–355 W in the CEC list.

CEC listed · Feb 11, 2021UL 61730
Power class
  • Power (STC)345 WCEC nameplate
  • Efficiency≈19.3%calculated from area
  • %/°C Pmax−0.361CEC listing test
  • PTC / STC92.6%PTC 320 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 5 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
MSE335SX5K335 W40.3510.8532.8910.19≈18.7%310 WFeb 11, 2021
MSE340SX5K340 W40.5310.9133.0610.28≈19.0%315 WFeb 11, 2021
MSE345SX5K345 W40.7110.9733.2410.38≈19.3%320 WFeb 11, 2021
MSE350SX5K350 W40.9511.0533.4110.48≈19.6%324 WFeb 11, 2021
MSE355SX5K355 W40.9911.1033.5110.59≈19.8%329 WJun 11, 2021
≈ efficiency = Pmax ÷ CEC-listed area 1.79 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.361 %/°C
Voc coefficient β−0.262 %/°C
Isc coefficient α+0.049 %/°C
Operating cell temperatureNOCT 45.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
335 W257.1 W30.61 V × 8.4 A68.1 W102%
340 W260.7 W30.77 V × 8.47 A69.1 W102%
345 W264.7 W30.94 V × 8.55 A70.1 W102%
350 W268.6 W31.1 V × 8.64 A71.1 W102%
355 W273.7 W31.36 V × 8.73 A72.4 W102%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
2
PVEL Scorecards
Mission Solar Energy named Top Performer, 2024–2025
4
RETC PV Module Index
Mission Solar Energy recognized 2023–2026
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Mission Solar Energy

YearRecognition
2023High Achievement in Performance (Module efficiency)
2024Test Category High Achiever
2025Performance High Achiever
2026Performance discipline high achiever (Iam, Lid); Quality discipline high achiever (BOM verification); Test Category High Achiever

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.2 V
Voc when cold
per panel
26.6 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.2 / 26.6 V⚠ Works; below MPPT at peak heat1.19
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.2 / 26.6 V✗ Not a match: module voltage below MPPT range0.91
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.2 / 26.6 V⚠ Works; below MPPT at peak heat0.44
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.2 / 26.6 V⚠ Works; below MPPT at peak heat1.06
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.2 / 26.6 V⚠ Works; below MPPT at peak heat0.99
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67657811,5646.08
Palmdale1,83563312,6626.69
Chula Vista1,69658511,7026.11
Huntington Beach1,64356711,3375.89
Riverside1,69658511,7026.21
Santa Clarita1,72459511,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 345 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Mission Solar Energy MSE345SX5K345 W≈19.3%−0.36140.7110.97brand 2×—
LONGi LR4-60HPB-345M345 W≈19.5%−0.33940.211.06product 2021, 2022193
JinkoSolar JKM345M-60HBL345 W≈20.4%−0.40641.210.91brand 12× (2014–2026)45
REC Group REC345AA345 W≈20.5%−0.27943.410.12brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Mission Solar Energy

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

MSExxxSX9R · 4MSExxxSX5R · 2MSExxxHT0B · 1MSExxxSX6Z · 1TXS6-xxx120BB · 1TXS6-xxx144BB · 1

Questions & answers

How efficient is the Mission Solar Energy MSE345SX5K?

Calculated from the panel area (1.79 m²): about 19.3% for the 345 W class. 345 W over 1.79 m² equals about 193 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 578 kWh per year per 345 W panel in Los Angeles and about 633 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.361 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.2 V, Vmp at 74 °C cell = 26.6 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Mission Solar Energy was named a Top Performer in 2 Scorecards (2024–2025).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2024–2025.
  5. RETC — PV Module Index reports 2023–2026.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).