144 cells. Power classes 290–500 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| FLEX-03 290W | 290 W | 47.20 | 9.27 | 37.20 | 7.83 | ≈13.1% | 251 W | Oct 21, 2021 |
| FLEX-03 300W | 300 W | 48.00 | 9.21 | 38.10 | 7.89 | ≈13.6% | 260 W | Oct 21, 2021 |
| FLEX-03 310W | 310 W | 48.70 | 9.14 | 39.00 | 7.96 | ≈14.0% | 269 W | Oct 21, 2021 |
| FLEX-03 320W | 320 W | 49.50 | 9.08 | 40.00 | 8.02 | ≈14.5% | 278 W | Oct 21, 2021 |
| FLEX-03 470W | 470 W | 74.80 | 9.19 | 59.60 | 7.91 | ≈15.7% | 412 W | Oct 21, 2021 |
| FLEX-03 480W | 480 W | 75.60 | 9.15 | 60.50 | 7.95 | ≈16.0% | 422 W | Oct 21, 2021 |
| FLEX-03 490W | 490 W | 76.40 | 9.11 | 61.40 | 7.99 | ≈16.3% | 430 W | Oct 21, 2021 |
| FLEX-03 500W | 500 W | 77.20 | 9.07 | 62.40 | 8.03 | ≈16.7% | 440 W | Oct 21, 2021 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.519 %/°C |
| Voc coefficient β | −0.355 %/°C |
| Operating cell temperature | NOCT 49.1 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 290 W | 208.4 W | 33.31 V × 6.26 A | 51.8 W | 89% |
| 300 W | 215.1 W | 34.11 V × 6.3 A | 53.5 W | 89% |
| 310 W | 222.1 W | 34.92 V × 6.36 A | 55.2 W | 89% |
| 320 W | 229.5 W | 35.82 V × 6.41 A | 57.1 W | 89% |
| 470 W | 321.1 W | 53.16 V × 6.04 A | — | — |
| 480 W | 327.6 W | 53.97 V × 6.07 A | — | — |
| 490 W | 334.1 W | 54.77 V × 6.1 A | — | — |
| 500 W | 341.3 W | 55.66 V × 6.13 A | — | — |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 536 | 11,799 | 6.08 |
| Palmdale | 1,835 | 587 | 12,918 | 6.69 |
| Chula Vista | 1,696 | 543 | 11,940 | 6.11 |
| Huntington Beach | 1,643 | 526 | 11,567 | 5.89 |
| Riverside | 1,696 | 543 | 11,940 | 6.21 |
| Santa Clarita | 1,724 | 552 | 12,137 | 6.28 |
Calculated from the panel area (2.61 m²): about 14.5% for the 320 W class. 320 W over 2.61 m² equals about 123 W per square meter.
PVWatts v8 with typical-year weather gives about 536 kWh per year per 320 W panel in Los Angeles and about 587 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.519 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 26.9% below the STC rating.