Cali-GrafCali-Graf
Solar panelMeyer Burger

Meyer Burger Meyer Burger Black 385

120 half-cut cells, HJT. Power classes 370–395 W in the CEC list.

CEC listed · Jun 1, 2022UL 61730HJTMade in GermanySeen in 2 SoCal permits
Power class
  • Power (STC)385 WCEC nameplate
  • Efficiency≈20.9%calculated from area
  • %/°C Pmax−0.26CEC test: −0.248
  • PTC / STC95.5%PTC 368 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
Meyer Burger Black, 370W370 W44.3810.5337.469.88≈20.1%353 WJun 1, 2022
Meyer Burger Black, 375W375 W44.5010.6038.009.90≈20.4%358 WJun 1, 2022
Meyer Burger Black, 380W380 W44.6010.6038.2010.00≈20.7%363 WJun 1, 2022
Meyer Burger Black, 385W385 W44.6010.7038.4010.10≈20.9%368 WJun 1, 2022
Meyer Burger Black, 390W390 W44.7010.8038.5010.20≈21.2%373 WJun 1, 2022
Meyer Burger Black, 395W395 W44.7010.9038.7010.30≈21.5%377 WJun 1, 2022
≈ efficiency = Pmax ÷ panel area 1.839 m² (datasheet size).

Build & dimensions

Meyer Burger datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

Meyer Burger datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.26 %/°C−0.248 %/°C
Voc coefficient β−0.23 %/°C−0.235 %/°C
Isc coefficient α+0.03 %/°C+0.041 %/°C
Vmp coefficient≈ −0.29 %/°C—
Operating cell temperature—NOCT 44.4 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
370 W279.1 W35.43 V × 7.88 A68.6 W93%
375 W283.7 W35.94 V × 7.89 A69.8 W93%
380 W288.1 W36.13 V × 7.97 A70.8 W93%
385 W292.5 W36.32 V × 8.05 A71.9 W93%
390 W296.1 W36.41 V × 8.13 A72.8 W93%
395 W300.6 W36.6 V × 8.21 A73.9 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Certifications

CEC PV Module List (Oct 7, 2026) · Meyer Burger datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62804IEC 62790IEC 62852

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
1
PVEL Scorecards
Meyer Burger, 2024
3
RETC PV Module Index
Meyer Burger recognized 2023–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Meyer Burger

YearRecognition
2023High Achievement in Performance (Ptc-to-stc ratio, Module efficiency)
2024Test Category High Achiever
2025Performance High Achiever

Inverter compatibility & string sizing

Meyer Burger datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
47 V
Voc when cold
per panel
32.9 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V47 / 32.9 V✓ Within range1.33
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V47 / 32.9 V✗ Not a match: module voltage below MPPT range1.01
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V47 / 32.9 V✓ Within range0.49
Enphase IQ8M-72-2-US260–460 W60 V30–45 V47 / 32.9 V✓ Within range1.18
Enphase IQ8A-72-2-US295–500 W60 V32–45 V47 / 32.9 V✓ Within range1.1
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67664511,6156.08
Palmdale1,83570612,7176.69
Chula Vista1,69665311,7536.11
Huntington Beach1,64363311,3865.89
Riverside1,69665311,7536.21
Santa Clarita1,72466411,9476.28
758Jan759Feb974Mar1,076Apr1,062May1,129Jun1,189Jul1,203Aug1,052Sep928Oct798Nov690DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 385 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Meyer Burger Meyer Burger Black 385385 W≈20.9%−0.24844.610.7brand 1×2
Qcells Q.PEAK DUO BLK ML-G10+ 385385 W≥19.6%−0.36245.1911.04product 2022, 2023221
JA Solar JAM54S31-385/MR385 W≈20.3%−0.32936.7113.52product 2023, 2024152
REC Group REC385AA Pure385 W≈21.5%−0.25648.510.1brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About Meyer Burger

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index

Other series by SoCal permits

MB_WG144C5SMB_WG144C1SMB_WG144C2SMB_WG144C3SMB_WG144C4SMB_WG144C6S

Questions & answers

How efficient is the Meyer Burger Meyer Burger Black 385?

Calculated from the panel area (1.84 m²): about 20.9% for the 385 W class. 385 W over 1.84 m² equals about 209 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 645 kWh per year per 385 W panel in Los Angeles and about 706 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.26 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 13.4% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 47 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 47 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

How big and heavy is it?

69.6 × 41 × 1.38 in (1,767 × 1,041 × 35 mm), 43.4 lb (19.7 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Meyer Burger was named a Top Performer in 1 Scorecard (2024).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Meyer Burger — manufacturer datasheet “Meyer Burger Black 375 – 395 Wp For maximum yields combined with outstanding”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. RETC — PV Module Index reports 2023–2025.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Jun 2025). Equipment matched from permit descriptions by model number.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).