120 half-cut cells, HJT. Power classes 370–395 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| Meyer Burger Black, 370W | 370 W | 44.38 | 10.53 | 37.46 | 9.88 | ≈20.1% | 353 W | Jun 1, 2022 |
| Meyer Burger Black, 375W | 375 W | 44.50 | 10.60 | 38.00 | 9.90 | ≈20.4% | 358 W | Jun 1, 2022 |
| Meyer Burger Black, 380W | 380 W | 44.60 | 10.60 | 38.20 | 10.00 | ≈20.7% | 363 W | Jun 1, 2022 |
| Meyer Burger Black, 385W | 385 W | 44.60 | 10.70 | 38.40 | 10.10 | ≈20.9% | 368 W | Jun 1, 2022 |
| Meyer Burger Black, 390W | 390 W | 44.70 | 10.80 | 38.50 | 10.20 | ≈21.2% | 373 W | Jun 1, 2022 |
| Meyer Burger Black, 395W | 395 W | 44.70 | 10.90 | 38.70 | 10.30 | ≈21.5% | 377 W | Jun 1, 2022 |
| Datasheet | CEC listing test | |
|---|---|---|
| Pmax coefficient γ | −0.26 %/°C | −0.248 %/°C |
| Voc coefficient β | −0.23 %/°C | −0.235 %/°C |
| Isc coefficient α | +0.03 %/°C | +0.041 %/°C |
| Vmp coefficient | ≈ −0.29 %/°C | — |
| Operating cell temperature | — | NOCT 44.4 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 370 W | 279.1 W | 35.43 V × 7.88 A | 68.6 W | 93% |
| 375 W | 283.7 W | 35.94 V × 7.89 A | 69.8 W | 93% |
| 380 W | 288.1 W | 36.13 V × 7.97 A | 70.8 W | 93% |
| 385 W | 292.5 W | 36.32 V × 8.05 A | 71.9 W | 93% |
| 390 W | 296.1 W | 36.41 V × 8.13 A | 72.8 W | 93% |
| 395 W | 300.6 W | 36.6 V × 8.21 A | 73.9 W | 94% |
| Year | Recognition |
|---|---|
| 2023 | High Achievement in Performance (Ptc-to-stc ratio, Module efficiency) |
| 2024 | Test Category High Achiever |
| 2025 | Performance High Achiever |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–12 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–12 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–12 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–10 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 47 / 32.9 V | ✓ Within range | 1.33 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 47 / 32.9 V | ✗ Not a match: module voltage below MPPT range | 1.01 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 47 / 32.9 V | ✓ Within range | 0.49 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 47 / 32.9 V | ✓ Within range | 1.18 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 47 / 32.9 V | ✓ Within range | 1.1 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 645 | 11,615 | 6.08 |
| Palmdale | 1,835 | 706 | 12,717 | 6.69 |
| Chula Vista | 1,696 | 653 | 11,753 | 6.11 |
| Huntington Beach | 1,643 | 633 | 11,386 | 5.89 |
| Riverside | 1,696 | 653 | 11,753 | 6.21 |
| Santa Clarita | 1,724 | 664 | 11,947 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| Meyer Burger Meyer Burger Black 385 | 385 W | ≈20.9% | −0.248 | 44.6 | 10.7 | brand 1× | 2 |
| Qcells Q.PEAK DUO BLK ML-G10+ 385 | 385 W | ≥19.6% | −0.362 | 45.19 | 11.04 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-385/MR | 385 W | ≈20.3% | −0.329 | 36.71 | 13.52 | product 2023, 2024 | 152 |
| REC Group REC385AA Pure | 385 W | ≈21.5% | −0.256 | 48.5 | 10.1 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (1.84 m²): about 20.9% for the 385 W class. 385 W over 1.84 m² equals about 209 W per square meter.
PVWatts v8 with typical-year weather gives about 645 kWh per year per 385 W panel in Los Angeles and about 706 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.26 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 13.4% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 47 V, Vmp at 74 °C cell = 32.9 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 47 V vs max input 60 V; Vmp when hot 32.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
69.6 × 41 × 1.38 in (1,767 × 1,041 × 35 mm), 43.4 lb (19.7 kg).
This exact series is not in published PVEL Top Performer tables; Meyer Burger was named a Top Performer in 1 Scorecard (2024).