Cali-GrafCali-Graf
Solar panelMessisolar New Energy

Messisolar New Energy MS-48N-BH-450M

96 cells, bifacial, glass (dual-glass module). 450 W in the CEC list.

CEC listed · Feb 23, 2026UL 61730Bifacial
  • Power (STC)450 WCEC nameplate
  • Efficiency≈22.7%calculated from area
  • %/°C Pmax−0.304CEC listing test
  • PTC / STC94.1%PTC 424 W (CEC)

Electrical ratings (STC)

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
MS-48N-BH-450M450 W35.0316.0530.0814.97≈22.7%424 WFeb 23, 2026
≈ efficiency = Pmax ÷ CEC-listed area 1.98 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.304 %/°C
Voc coefficient β−0.250 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 46 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
450 W339.1 W28.07 V × 12.08 A87.4 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
37 V
Voc when cold
per panel
24.9 V
Vmp when hot
per panel
16
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–16
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet4–16
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet5–16
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window10–13

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V37 / 24.9 V✗ Not a match: module voltage below MPPT range1.18
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V37 / 24.9 V⚠ Works; below MPPT at peak heat0.58
Enphase IQ8M-72-2-US260–460 W60 V30–45 V37 / 24.9 V⚠ Works; below MPPT at peak heat1.38
Enphase IQ8A-72-2-US295–500 W60 V32–45 V37 / 24.9 V✗ Not a match: module voltage below MPPT range1.29
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67675412,0676.08
Palmdale1,83582613,2126.69
Chula Vista1,69676312,2116.11
Huntington Beach1,64373911,8305.89
Riverside1,69676312,2116.21
Santa Clarita1,72477612,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 450 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Messisolar New Energy MS-48N-BH-450M450 W≈22.7%−0.30435.0316.05——
Qcells Q.TRON BLK M-G2+ 445445 W≈22.8%−0.27640.1613.98brand 11× (2016–2026)40
Hyundai Energy Solutions HiN-T450NF(BK)450 W≈23.2%−0.29839.214.53brand 5× (2017–2025)37
REC Group REC450AA Pure-RX450 W≈22.3%−0.24865.18.81brand 9× (2016–2025)33
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the Messisolar New Energy MS-48N-BH-450M?

Calculated from the panel area (1.98 m²): about 22.7% for the 450 W class. 450 W over 1.98 m² equals about 227 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 754 kWh per year per 450 W panel in Los Angeles and about 826 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.304 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–16 panels per string (Voc at 2 °C = 37 V, Vmp at 74 °C cell = 24.9 V). Final design must follow the inverter manual and NEC 690.7.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  3. Hyundai Energy Solutions — datasheet [US] NF(BK)(HiN) Series (N TOPCon Bifacial) 435~445W.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).