Cali-GrafCali-Graf
Solar panelMerlin Solar Technologies

Merlin Solar Technologies RFP-F036B175L

36 cells, PERC. Power classes 170–180 W in the CEC list.

CEC listed · Jul 3, 2023UL 61730
Power class
  • Power (STC)175 WCEC nameplate
  • Efficiency≈16.1%calculated from area
  • %/°C Pmax−0.331CEC listing test
  • PTC / STC89.6%PTC 157 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 3 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
RFP-F036B170L170 W24.368.9620.078.49≈15.6%152 WJul 3, 2023
RFP-F036B175L175 W24.459.0220.408.59≈16.1%157 WJul 3, 2023
RFP-F036B180L180 W24.529.0720.728.69≈16.5%161 WJul 3, 2023
≈ efficiency = Pmax ÷ CEC-listed area 1.09 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.331 %/°C
Voc coefficient β−0.266 %/°C
Isc coefficient α+0.043 %/°C
Operating cell temperatureNOCT 55.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
170 W114.9 W17.21 V × 6.68 A29.7 W87%
175 W118.2 W17.5 V × 6.76 A30.6 W87%
180 W121.5 W17.77 V × 6.83 A31.4 W87%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

RETC PV Module Index
1
RETC PV Module Index
Merlin Solar Technologies, 2023
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Merlin Solar Technologies

YearRecognition
2023High Achievement in Performance (Lid resistance)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
25.9 V
Voc when cold
per panel
16.7 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Microinverter tables are not shown for panels under 200 W.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6762938,7996.08
Palmdale1,8353219,6346.69
Chula Vista1,6962978,9046.11
Huntington Beach1,6432888,6265.89
Riverside1,6962978,9046.21
Santa Clarita1,7243029,0516.28
574Jan575Feb738Mar815Apr805May855Jun901Jul911Aug797Sep703Oct604Nov523DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Merlin Solar Technologies RFP-F036B175L?

Calculated from the panel area (1.09 m²): about 16.1% for the 175 W class. 175 W over 1.09 m² equals about 161 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 293 kWh per year per 175 W panel in Los Angeles and about 321 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.331 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.1% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. RETC — PV Module Index report.
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  4. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).