Cali-GrafCali-Graf
Solar panelMerlin Solar Technologies

Merlin Solar Technologies FXS 150L-B

36 cells. Power classes 145–155 W in the CEC list.

CEC listed · Mar 11, 2020UL 1703
Power class
  • Power (STC)150 WCEC nameplate
  • Efficiency≈13.5%calculated from area
  • %/°C Pmax−0.413CEC listing test
  • PTC / STC88.3%PTC 132 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 3 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FXS 145L-B145 W22.678.3518.028.10≈13.1%128 WMar 11, 2020
FXS 150L-B150 W23.018.4618.358.21≈13.5%132 WMar 11, 2020
FXS 155L-B155 W23.258.5518.758.28≈14.0%137 WMar 11, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.11 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.413 %/°C
Voc coefficient β−0.310 %/°C
Isc coefficient α+0.051 %/°C
Operating cell temperatureNOCT 51.3 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
145 W104.5 W16.38 V × 6.38 A28.8 W99%
150 W107.8 W16.68 V × 6.46 A29.7 W99%
155 W111.1 W17.04 V × 6.52 A30.6 W99%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

RETC PV Module Index
1
RETC PV Module Index
Merlin Solar Technologies, 2023
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Merlin Solar Technologies

YearRecognition
2023High Achievement in Performance (Lid resistance)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
24.7 V
Voc when cold
per panel
14.2 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Microinverter tables are not shown for panels under 200 W.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6762517,5426.08
Palmdale1,8352758,2586.69
Chula Vista1,6962547,6326.11
Huntington Beach1,6432467,3945.89
Riverside1,6962547,6326.21
Santa Clarita1,7242597,7586.28
492Jan493Feb632Mar698Apr690May733Jun772Jul781Aug683Sep603Oct518Nov448DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Merlin Solar Technologies FXS 150L-B?

Calculated from the panel area (1.11 m²): about 13.5% for the 150 W class. 150 W over 1.11 m² equals about 135 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 251 kWh per year per 150 W panel in Los Angeles and about 275 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.413 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 21.4% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. RETC — PV Module Index report.
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  4. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).