Merlin Solar Technologies FX 155L-B

36 cells. Power classes 150–160 W in the CEC list.

CEC listed · Mar 11, 2020UL 1703
Power class
  • Power (STC)155 WCEC nameplate
  • Efficiency≈14.0%calculated from area
  • %/°C Pmax−0.410CEC listing test
  • PTC / STC89.5%PTC 139 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 3 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
FX 150L-B150 W22.678.3518.588.10≈13.5%134 WMar 11, 2020
FX 155L-B155 W23.018.4618.928.21≈14.0%139 WMar 11, 2020
FX 160L-B160 W23.258.5519.348.28≈14.4%143 WMar 11, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.11 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.410 %/°C
Voc coefficient β−0.313 %/°C
Isc coefficient α+0.031 %/°C
Operating cell temperatureNOCT 49 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
150 W105.8 W16.61 V × 6.37 A27.5 W92%
155 W109.1 W16.92 V × 6.45 A28.4 W92%
160 W112.5 W17.29 V × 6.51 A29.3 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

RETC PV Module Index
1
RETC PV Module Index
Merlin Solar Technologies, 2023
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — Merlin Solar Technologies

YearRecognition
2023High Achievement in Performance (Lid resistance)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8
24.7 V
Voc when cold
per panel
14.8 V
Vmp when hot
per panel
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
Microinverter tables are not shown for panels under 200 W.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,6762607,7936.08
Palmdale1,8352848,5336.69
Chula Vista1,6962637,8866.11
Huntington Beach1,6432557,6405.89
Riverside1,6962637,8866.21
Santa Clarita1,7242678,0176.28
509Jan509Feb653Mar722Apr713May757Jun798Jul807Aug706Sep623Oct535Nov463DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Questions & answers

How efficient is the Merlin Solar Technologies FX 155L-B?

Calculated from the panel area (1.11 m²): about 14% for the 155 W class. 155 W over 1.11 m² equals about 140 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 260 kWh per year per 155 W panel in Los Angeles and about 284 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.410 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 21.2% below the STC rating.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List (snapshot Oct 7, 2026).
  2. RETC — PV Module Index report.
  3. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  4. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).