Cali-GrafCali-Graf
Solar panelMaxeon Solar Technologies

Maxeon Solar Technologies SPR-X22-475-COM

128 cells. Power classes 470–485 W in the CEC list.

CEC listed · Dec 12, 2022UL 6173025-yr product + 25-yr performance warrantyMade in Philippines
Power class
  • Power (STC)475 Wtolerance +5 / −0 %
  • Efficiency≈22.0%calculated from area
  • %/°C Pmax−0.352CEC listing test
  • Degradation / yr0.25%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPR-X22-470-COM470 W91.506.8977.906.03≈21.8%438 WFeb 21, 2023
SPR-X22-475-COM475 W92.506.4578.506.07≈22.0%443 WFeb 21, 2023
SPR-X22-480-COM480 W92.906.4879.006.08≈22.2%453 WFeb 21, 2023
SPR-X22-485-COM485 W92.706.5578.806.16≈22.5%458 WDec 12, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.16 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.352 %/°C
Voc coefficient β−0.293 %/°C
Isc coefficient α+0.031 %/°C
Operating cell temperatureNOCT 45.7 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
470 W346.5 W72.19 V × 4.8 A88.3 W94%
475 W351.3 W72.74 V × 4.83 A89.7 W94%
480 W357.4 W74.31 V × 4.81 A88.6 W92%
485 W361.2 W74.12 V × 4.87 A89.6 W92%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Maxeon Solar Technologies datasheet
Packaging: 40 per pallet · 440 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716IEC 62804IEC 60068Fire rating Class C (UL 61730)ISO 14001ISO 45001ISO 9001

Independent reliability testing

Kiwa PVEL Scorecard
8
PVEL Scorecards
Maxeon Solar Technologies named Top Performer, 2017–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
98.7 V
Voc when cold
per panel
63.8 V
Vmp when hot
per panel
6
Max panels / string
max DC 600 V
1
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet1–6
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet2–6
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet2–6
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window4–5

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V98.7 / 63.8 V✗ Not allowed: cold Voc above max input1.25
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V98.7 / 63.8 V✗ Not allowed: cold Voc above max input0.61
Enphase IQ8A-72-2-US295–500 W60 V32–45 V98.7 / 63.8 V✗ Not allowed: cold Voc above max input1.36
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67679611,9426.08
Palmdale1,83587213,0746.69
Chula Vista1,69680612,0846.11
Huntington Beach1,64378011,7065.89
Riverside1,69680612,0846.21
Santa Clarita1,72481912,2846.28
779Jan780Feb1,001Mar1,106Apr1,092May1,161Jun1,223Jul1,237Aug1,082Sep954Oct820Nov710DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 475 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Maxeon Solar Technologies SPR-X22-475-COM475 W≈22%−0.35292.56.45brand 8×—
REC Group REC475AA Pure-RX475 W≈23.5%−0.24865.79brand 9× (2016–2025)33
SEG Solar SEG-455-BTD-BG455 W≈23.3%−0.26239.7614.11product 2023, 2024, 2025, 20268
Qcells Q.PEAK DUO XL-G10.d 475475 W≥20.5%−0.34053.5811.24product 20236
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Maxeon Solar Technologies

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

SPR-MAX6 · 2SPR-MAX6-xxx-BLKSPR-MAX3SPR-MAX3-xxx-BLKSPR-MAX3-xxx-BLK-RSPR-MAX3-xxx-COM

Questions & answers

How efficient is the Maxeon Solar Technologies SPR-X22-475-COM?

Calculated from the panel area (2.16 m²): about 22% for the 475 W class. 475 W over 2.16 m² equals about 220 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 796 kWh per year per 475 W panel in Los Angeles and about 872 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.352 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 18.2% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 1–6 panels per string (Voc at 2 °C = 98.7 V, Vmp at 74 °C cell = 63.8 V). Final design must follow the inverter manual and NEC 690.7.

What does the warranty cover?

25 years on the product and 25 years on performance (manufacturer datasheet).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; Maxeon Solar Technologies was named a Top Performer in 8 Scorecards (2017–2025).

What fire rating does it have?

UL 61730 fire rating Class C per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Maxeon Solar Technologies — datasheet Maxeon 3 SPR- X22-XXX-COM Commercial Solar Panel.
  3. SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
  4. Qcells — manufacturer datasheet “Q.PEAK DUO XL-G10.d ENDURING HIGH PERFORMANCE”.
  5. Maxeon Solar Technologies — document library on the manufacturer’s website (links above).
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  9. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  10. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  11. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).