CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ
−0.493 %/°C
Voc coefficient β
−0.299 %/°C
Isc coefficient α
+0.046 %/°C
Operating cell temperature
NOCT 46.4 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.
Away from lab conditions — CEC listing test points
Class
Pmax at NOCT
Vmp × Imp at NOCT
Pmax at 200 W/m²
Low-light efficiency vs STC
495 W
367 W
34.19 V × 10.73 A
96.6 W
98%
500 W
370.6 W
34.38 V × 10.78 A
97.5 W
98%
505 W
374.6 W
34.56 V × 10.84 A
98.5 W
98%
510 W
367.5 W
33.9 V × 10.84 A
97.1 W
95%
515 W
371 W
34.17 V × 10.86 A
98 W
95%
520 W
374.7 W
34.44 V × 10.88 A
99 W
95%
525 W
389.2 W
35.49 V × 10.96 A
102.4 W
98%
530 W
381.8 W
34.98 V × 10.91 A
100.8 W
95%
535 W
385.6 W
35.26 V × 10.94 A
101.8 W
95%
540 W
389.1 W
35.53 V × 10.95 A
102.8 W
95%
545 W
392.9 W
35.8 V × 10.98 A
103.8 W
95%
550 W
396.8 W
36.07 V × 11 A
104.8 W
95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).
Independent reliability testing
Kiwa PVEL Scorecard
8
PVEL Scorecards
Maxeon Solar Technologies named Top Performer, 2017–2025
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
49.8 V
Voc when cold
per panel
28 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
3–12
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–12
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
4–12
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
9–10
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
49.8 / 28 V
✗ Not a match: module voltage below MPPT range
1.37
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
49.8 / 28 V
⚠ Works; below MPPT at peak heat
0.67
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
872
11,330
6.08
Palmdale
1,835
954
12,405
6.69
Chula Vista
1,696
882
11,465
6.11
Huntington Beach
1,643
854
11,107
5.89
Riverside
1,696
882
11,465
6.21
Santa Clarita
1,724
896
11,654
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 520 W panels
CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
Size
PVEL (product / brand)
SoCal permits (series)
Maxeon Solar Technologies SPR-P5-520-UPP
520 W
≈20%
−0.493
46.6
14.76
—
brand 8×
—
SEG Solar SEG-520-BTD-BG
520 W
≈26.6%
−0.290
40.9
16.13
67.8 × 44.6 in
product 2023, 2024, 2025, 2026
8
Canadian Solar CS6W-520MB-AG
520 W
≈20.2%
−0.324
48.4
13.7
89.2 × 44.6 in
product 2024
1
LONGi LR5-72HBD-520M
520 W
≈20.3%
−0.323
48.9
13.57
88.8 × 44.6 in
product 2026
1
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
About Maxeon Solar Technologies
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits
How efficient is the Maxeon Solar Technologies SPR-P5-520-UPP?
Calculated from the panel area (2.6 m²): about 20% for the 520 W class. 520 W over 2.6 m² equals about 200 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 872 kWh per year per 520 W panel in Los Angeles and about 954 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.493 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 25.5% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–12 panels per string (Voc at 2 °C = 49.8 V, Vmp at 74 °C cell = 28 V). Final design must follow the inverter manual and NEC 690.7.
Has this panel been reliability-tested?
This exact series is not in published PVEL Top Performer tables; Maxeon Solar Technologies was named a Top Performer in 8 Scorecards (2017–2025).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
SEG Solar — manufacturer datasheet “XXXTFHTPMBSDPN YUKON/Series )BMG$FMM/5ZQF501$PO”.
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.