72 cells. Power classes 450–480 W in the CEC list; datasheet covers 450–475 W.

CEC listed · Aug 11, 2022UL 6173025-yr product + 25-yr performance warrantyPVEL Top Performer 2024Made in Malaysia
Power class
  • Power (STC)465 Wtolerance +5 / −0 %
  • Efficiency≈21.9%calculated from area
  • %/°C Pmax−0.296CEC listing test
  • Degradation / yr0.25%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet · Cali-Graf calculation · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPR-MAX6-450-COM450 W52.4311.5142.7610.52≥21.2%423 WAug 11, 2022
SPR-MAX6-455-COM455 W52.4511.5242.9910.58≈21.5%428 WAug 11, 2022
SPR-MAX6-460-COM460 W52.4811.5443.2310.64≥21.6%433 WAug 11, 2022
SPR-MAX6-465-COM465 W52.5111.5543.4610.70≈21.9%437 WAug 11, 2022
SPR-MAX6-470-COM470 W52.5311.5643.6910.76≈22.2%442 WAug 11, 2022
SPR-MAX6-475-COM475 W52.5611.5743.9210.82≥22.3%447 WAug 11, 2022
SPR-MAX6-480-COM480 W52.5911.5844.1510.87≈22.6%452 WAug 11, 2022
≈ efficiency = Pmax ÷ CEC-listed area 2.12 m² for classes outside the datasheet.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.296 %/°C
Voc coefficient β−0.236 %/°C
Isc coefficient α+0.037 %/°C
Operating cell temperatureNOCT 46.5 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
450 W331.4 W40.04 V × 8.28 A84.4 W94%
455 W335.1 W40.25 V × 8.32 A85.3 W94%
460 W338.9 W40.48 V × 8.37 A86.3 W94%
465 W342.6 W40.69 V × 8.42 A87.2 W94%
470 W346.3 W40.91 V × 8.47 A88.2 W94%
475 W350.1 W41.12 V × 8.51 A89.1 W94%
480 W353.6 W41.34 V × 8.55 A90 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Maxeon Solar Technologies datasheet
Packaging: 29 per pallet · 638 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716IEC 62804IEC 60068MCSISO 14001ISO 45001ISO 9001

Independent reliability testing

Kiwa PVEL Scorecard
2024
PVEL Top Performer
this series
5
Tests passed as Top Performer
DH, HSS, MSS, PID, TC
8
PVEL Scorecards
Maxeon Solar Technologies named Top Performer, 2017–2025

PVEL Top Performer tests

YearProductTests
2024SPR-MAX6-xxx-COMDHPID
2024SPR-MAX6-xxx (closely related product name)DHHSSMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
55.4 V
Voc when cold
per panel
36.4 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–10
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–10
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–10
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V55.4 / 36.4 V⚠ Works; below MPPT at peak heat1.22
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V55.4 / 36.4 V✓ Within range0.6
Enphase IQ8A-72-2-US295–500 W60 V32–45 V55.4 / 36.4 V✓ Within range1.33
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67677911,6906.08
Palmdale1,83585312,7996.69
Chula Vista1,69678911,8306.11
Huntington Beach1,64376411,4605.89
Riverside1,69678911,8306.21
Santa Clarita1,72480212,0256.28
763Jan764Feb980Mar1,083Apr1,069May1,136Jun1,197Jul1,211Aug1,059Sep934Oct803Nov695DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 465 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
Maxeon Solar Technologies SPR-MAX6-465-COM465 W≈21.9%−0.29652.5111.5525 / 25 yrproduct 2024—
REC Group REC465AA Pure-RX465 W≈23%−0.24865.78.91—brand 9× (2016–2025)33
Aptos Solar DNA-120-MF10-465W465 W≈21.5%−0.36341.914.0730 yr—22
Canadian Solar CS6.1-54TM-465H465 W≥22.8%−0.30839.514.7725 yrproduct 2024, 20259
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Maxeon Solar Technologies

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

SPR-MAX6 · 2SPR-MAX6-xxx-BLKSPR-MAX3SPR-MAX3-xxx-BLKSPR-MAX3-xxx-BLK-RSPR-MAX3-xxx-COM

Questions & answers

How efficient is the Maxeon Solar Technologies SPR-MAX6-465-COM?

Calculated from the panel area (2.12 m²): about 21.9% for the 465 W class. 465 W over 2.12 m² equals about 219 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 779 kWh per year per 465 W panel in Los Angeles and about 853 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.296 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55.4 V, Vmp at 74 °C cell = 36.4 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with APsystems (Alt Power System) DS3-L microinverters?

Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 55.4 V vs max input 60 V; Vmp when hot 36.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on the product and 25 years on performance (manufacturer datasheet).

Has this panel been reliability-tested?

SPR-MAX6-xxx-COM was a PVEL Top Performer in 2024 (DH, PID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Maxeon Solar Technologies — datasheet Maxeon 6 SPR-MAX6-XXX-COM Commercial Solar Panel.
  3. Aptos Solar — datasheet Legacy Products.
  4. Canadian Solar — datasheet TOPHiKu6 (All-Black) N-type TOPCon Technology CS6.1-54TM-435|440|445|450|455|460|465H.
  5. Maxeon Solar Technologies — document library on the manufacturer’s website (links above).
  6. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  7. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  8. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.