Details describe the tested sample, not every module of the series.
Inverter compatibility & string sizing
CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
55.4 V
Voc when cold
per panel
36.4 V
Vmp when hot
per panel
10
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.
String inverters most named in SoCal permits
Inverter
Max DC input
MPPT
Window source
Panels per string
Tesla 1538000-xx-y
600 V
60–480 V
datasheet
2–10
Solis (Ginlong) S6-EH1P10K-H-US
600 V
80–520 V
datasheet
3–10
Solis (Ginlong) Solis-1P7.6K-4G-US
600 V
100–500 V
datasheet
3–10
Qcells Q.VOLT H7.6SX
498 V
234–498 V
CEC test window
7–9
Microinverters (one per panel)
Microinverter
Recommended module power
Max DC input
MPPT
Voc cold / Vmp hot
Check
DC/AC
Enphase IQ8X-80-M-US
320–540 W
79.5 V
43–60 V
55.4 / 36.4 V
⚠ Works; below MPPT at peak heat
1.22
APsystems (Alt Power System) DS3-L
265–570 W
60 V
28–45 V
55.4 / 36.4 V
✓ Within range
0.6
Enphase IQ8A-72-2-US
295–500 W
60 V
32–45 V
55.4 / 36.4 V
✓ Within range
1.33
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.
Expected production in Southern California
NLR PVWatts v8 · Cali-Graf calculation
City
kWh / kW / yr
kWh / panel / yr
kWh / system / yr
Sun, kWh/m²/day
Los Angeles
1,676
779
11,690
6.08
Palmdale
1,835
853
12,799
6.69
Chula Vista
1,696
789
11,830
6.11
Huntington Beach
1,643
764
11,460
5.89
Riverside
1,696
789
11,830
6.21
Santa Clarita
1,724
802
12,025
6.28
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.
Compare with similar 465 W panels
CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · datasheets · building permits
Panel
Pmax
Efficiency
γ Pmax (CEC)
Voc, V
Isc, A
Warranty
PVEL (product / brand)
SoCal permits (series)
Maxeon Solar Technologies SPR-MAX6-465-COM
465 W
≈21.9%
−0.296
52.51
11.55
25 / 25 yr
product 2024
—
REC Group REC465AA Pure-RX
465 W
≈23%
−0.248
65.7
8.91
—
brand 9× (2016–2025)
33
Aptos Solar DNA-120-MF10-465W
465 W
≈21.5%
−0.363
41.9
14.07
30 yr
—
22
Canadian Solar CS6.1-54TM-465H
465 W
≥22.8%
−0.308
39.5
14.77
25 yr
product 2024, 2025
9
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.
How efficient is the Maxeon Solar Technologies SPR-MAX6-465-COM?
Calculated from the panel area (2.12 m²): about 21.9% for the 465 W class. 465 W over 2.12 m² equals about 219 W per square meter.
How much energy does one panel produce in Los Angeles or Palmdale?
PVWatts v8 with typical-year weather gives about 779 kWh per year per 465 W panel in Los Angeles and about 853 kWh in Palmdale (20° roof, facing south, 14% system losses).
How much power does it lose on a hot roof?
With γ = −0.296 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15.3% below the STC rating.
How many panels fit on one string?
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–10 panels per string (Voc at 2 °C = 55.4 V, Vmp at 74 °C cell = 36.4 V). Final design must follow the inverter manual and NEC 690.7.
Does it work with APsystems (Alt Power System) DS3-L microinverters?
Voltage check against the APsystems (Alt Power System) datasheet: Voc when cold 55.4 V vs max input 60 V; Vmp when hot 36.4 V vs MPPT low 28 V; recommended module power 265–570 W. Confirm on the microinverter maker’s compatibility list.
What does the warranty cover?
25 years on the product and 25 years on performance (manufacturer datasheet).
Has this panel been reliability-tested?
SPR-MAX6-xxx-COM was a PVEL Top Performer in 2024 (DH, PID).
Sources
California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
Building permits — Southern California permit portals. Equipment matched from permit descriptions.
Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).
Get your free estimate
Three fields, and Cali Energy calls back within 30 minutes during business hours.
Thanks!
We got your request and will call back within 30 minutes during business hours.