Cali-GrafCali-Graf
Solar panelMaxeon Solar Technologies

Maxeon Solar Technologies SPR-MAX6-410-BLK

66 cells. Power classes 400–425 W in the CEC list; datasheet covers 410–425 W.

CEC listed · Feb 12, 2024UL 6173025-yr product + 25-yr performance warrantyMade in Malaysia
Power class
  • Power (STC)410 Wtolerance +5 / −0 %
  • Efficiency≥21.2%datasheet minimum
  • %/°C Pmax−0.290CEC listing test
  • Degradation / yr0.25%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · Maxeon Solar Technologies datasheet · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
SPR-MAX6-400-BLK400 W48.1011.2539.1010.24≈21.4%376 WFeb 12, 2024
SPR-MAX6-405-BLK405 W48.1011.2639.3010.30≈21.7%381 WFeb 12, 2024
SPR-MAX6-410-BLK410 W48.1011.2839.6010.37≥21.2%386 WFeb 12, 2024
SPR-MAX6-415-BLK415 W48.1011.2939.8010.43≥21.5%390 WFeb 12, 2024
SPR-MAX6-420-BLK420 W48.2011.3040.0010.49≈22.5%395 WFeb 12, 2024
SPR-MAX6-425-BLK425 W48.2011.3240.3010.58≥22.0%400 WFeb 12, 2024
≈ efficiency = Pmax ÷ CEC-listed area 1.87 m² for classes outside the datasheet.

Build & dimensions

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.290 %/°C
Voc coefficient β−0.236 %/°C
Isc coefficient α+0.044 %/°C
Operating cell temperatureNOCT 46.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
400 W300.7 W37.4 V × 8.04 A76.3 W95%
405 W304.2 W37.6 V × 8.09 A77.2 W95%
410 W308.9 W37.9 V × 8.15 A78.5 W96%
415 W312 W38.1 V × 8.19 A79.3 W96%
420 W315.6 W38.3 V × 8.24 A80.2 W95%
425 W318.9 W38.1 V × 8.37 A80.9 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

Maxeon Solar Technologies datasheet
Packaging: 25 per pallet · 600 per container

Certifications

CEC PV Module List (Oct 7, 2026) · Maxeon Solar Technologies datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716IEC 62804IEC 60068Fire rating Class C (UL 61730)ISO 14001ISO 45001ISO 9001

Independent reliability testing

Kiwa PVEL Scorecard
2024
PVEL Top Performer
closely related product name
5
Tests passed as Top Performer
DH, HSS, MSS, PID, TC
8
PVEL Scorecards
Maxeon Solar Technologies named Top Performer, 2017–2025

PVEL Top Performer tests

YearProductTests
2024SPR-MAX6-xxx (closely related product name)DHHSSMSSPIDTC

Tested bill of materials

Details describe the tested sample, not every module of the series.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
50.7 V
Voc when cold
per panel
33.1 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V50.7 / 33.1 V✓ Within range1.41
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V50.7 / 33.1 V✗ Not a match: module voltage below MPPT range1.08
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V50.7 / 33.1 V✓ Within range0.53
Enphase IQ8M-72-2-US260–460 W60 V30–45 V50.7 / 33.1 V✓ Within range1.26
Enphase IQ8A-72-2-US295–500 W60 V32–45 V50.7 / 33.1 V✓ Within range1.17
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67668711,6826.08
Palmdale1,83575212,7906.69
Chula Vista1,69669511,8216.11
Huntington Beach1,64367411,4525.89
Riverside1,69669511,8216.21
Santa Clarita1,72470712,0166.28
763Jan763Feb979Mar1,082Apr1,069May1,135Jun1,196Jul1,210Aug1,058Sep933Oct802Nov694DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 410 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
Maxeon Solar Technologies SPR-MAX6-410-BLK410 W≥21.2%−0.29048.111.28brand 8×—
Qcells Q.PEAK DUO BLK ML-G10+ 410410 W≈20.9%−0.33745.3711.2product 2022, 2023221
JA Solar JAM54S31-405/MR405 W≈21.3%−0.32937.2313.87product 2023, 2024152
REC Group REC410AA Pure410 W≈22.9%−0.2564910.35brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

About Maxeon Solar Technologies

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · building permits

Other series by SoCal permits

SPR-MAX6 · 2SPR-MAX3SPR-MAX3-xxx-BLKSPR-MAX3-xxx-BLK-RSPR-MAX3-xxx-COMSPR-MAX3-xxx-COM-R

Questions & answers

How efficient is the Maxeon Solar Technologies SPR-MAX6-410-BLK?

The Maxeon Solar Technologies datasheet guarantees at least 21.2% module efficiency for the 410 W class (up to 22% for 425 W). 410 W over 1.87 m² equals about 219 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 687 kWh per year per 410 W panel in Los Angeles and about 752 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.290 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 50.7 V, Vmp at 74 °C cell = 33.1 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 50.7 V vs max input 60 V; Vmp when hot 33.1 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on the product and 25 years on performance (manufacturer datasheet).

Has this panel been reliability-tested?

SPR-MAX6-xxx was a PVEL Top Performer in 2024 (DH, HSS, MSS, PID, TC) — a closely related product name.

What fire rating does it have?

UL 61730 fire rating Class C per datasheet.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Maxeon Solar Technologies — datasheet Maxeon 6 SPR-MAX6-XXX-BLK Home Solar Panel.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Maxeon Solar Technologies — document library on the manufacturer’s website (links above).
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2025.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).