144 cells, bifacial. Power classes 360–385 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| LR6-72HIBD-360M | 360 W | 47.70 | 9.64 | 39.40 | 9.14 | ≈18.5% | 336 W | Jan 21, 2020 |
| LR6-72HIBD-365M | 365 W | 47.90 | 9.72 | 39.60 | 9.22 | ≈18.7% | 340 W | Jan 21, 2020 |
| LR6-72HIBD-370M | 370 W | 48.10 | 9.80 | 39.80 | 9.30 | ≈19.0% | 345 W | Jan 21, 2020 |
| LR6-72HIBD-375M | 375 W | 48.30 | 9.87 | 40.00 | 9.38 | ≈19.2% | 350 W | Jan 21, 2020 |
| LR6-72HIBD-380M | 380 W | 48.50 | 9.97 | 40.20 | 9.47 | ≈19.5% | 355 W | Jan 21, 2020 |
| LR6-72HIBD-385M | 385 W | 48.70 | 10.03 | 40.40 | 9.53 | ≈19.7% | 360 W | Jan 21, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.330 %/°C |
| Voc coefficient β | −0.268 %/°C |
| Isc coefficient α | +0.049 %/°C |
| Operating cell temperature | NOCT 45.7 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 360 W | 268.4 W | 37.4 V × 7.18 A | 67 W | 93% |
| 365 W | 272.1 W | 37.59 V × 7.24 A | 67.9 W | 93% |
| 370 W | 275.9 W | 37.78 V × 7.3 A | 68.9 W | 93% |
| 375 W | 279.7 W | 37.97 V × 7.37 A | 69.8 W | 93% |
| 380 W | 283.8 W | 38.16 V × 7.44 A | 70.8 W | 93% |
| 385 W | 287 W | 38.35 V × 7.48 A | 71.6 W | 93% |
| Year | Recognition |
|---|---|
| 2023 | Overall Highest Achiever; High Achievement in Performance (Pan file performance, Module efficiency, Lid resistance); High Achievement in Quality (Thresher test); High Achievement in Reliability (Thermal cycle test, SDML, Damp heat test) |
| 2024 | Overall Highest Achiever |
| 2025 | Overall Highest Achiever |
| 2026 | Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Iam, Letid, PAN file, PTC-to-STC); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Hdt, Pid, Sdml, Tc, Uvid) |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 4–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 8–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 51.1 / 32.4 V | ✓ Within range | 1.28 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 51.1 / 32.4 V | ✗ Not a match: module voltage below MPPT range | 0.97 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 51.1 / 32.4 V | ✓ Within range | 0.47 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 51.1 / 32.4 V | ✓ Within range | 1.14 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 51.1 / 32.4 V | ✓ Within range | 1.06 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 620 | 11,782 | 6.08 |
| Palmdale | 1,835 | 679 | 12,900 | 6.69 |
| Chula Vista | 1,696 | 628 | 11,923 | 6.11 |
| Huntington Beach | 1,643 | 608 | 11,550 | 5.89 |
| Riverside | 1,696 | 628 | 11,923 | 6.21 |
| Santa Clarita | 1,724 | 638 | 12,120 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| LONGi LR6-72HIBD-370M | 370 W | ≈19% | −0.330 | 48.1 | 9.8 | brand 9× | — |
| Canadian Solar CS3N-375MS {Blk} | 375 W | ≈19% | −0.342 | 43.5 | 11.2 | product 2023 | 46 |
| REC Group REC370AA | 370 W | ≈21.9% | −0.258 | 44.1 | 10.55 | brand 9× (2016–2025) | 30 |
| Trina Solar TSM-370DE06X.05(II) | 370 W | ≈20.3% | −0.339 | 45.2 | 10.4 | product 2022 | 23 |
Calculated from the panel area (1.95 m²): about 19% for the 370 W class. 370 W over 1.95 m² equals about 190 W per square meter.
PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.330 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.1% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.1 V, Vmp at 74 °C cell = 32.4 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 51.1 V vs max input 60 V; Vmp when hot 32.4 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
Yes. Rear gain depends on mounting height and ground reflectance.
This exact series is not in published PVEL Top Performer tables; LONGi was named a Top Performer in 9 Scorecards (2017–2026). RETC named LONGi Overall Highest Achiever in 2023, 2024, 2025, 2026.