Cali-GrafCali-Graf
Solar panelLONGi

LONGi LR6-72HBD-370MC

144 half-cut cells, bifacial. Power classes 360–385 W in the CEC list.

CEC listed · Feb 21, 2020UL 1703Bifacial
Power class
  • Power (STC)370 WCEC nameplate
  • Efficiency≈19.0%calculated from area
  • %/°C Pmax−0.343CEC listing test
  • PTC / STC93.4%PTC 346 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 6 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LR6-72HBD-360MC360 W47.709.6439.409.14≈18.5%336 WFeb 21, 2020
LR6-72HBD-365MC365 W47.909.7239.609.22≈18.7%341 WFeb 21, 2020
LR6-72HBD-370MC370 W48.109.8039.809.30≈19.0%346 WFeb 21, 2020
LR6-72HBD-375MC375 W48.309.8740.009.38≈19.2%350 WFeb 21, 2020
LR6-72HBD-380MC380 W48.509.9740.209.47≈19.5%355 WFeb 21, 2020
LR6-72HBD-385MC385 W48.7010.0340.409.53≈19.7%360 WFeb 21, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.95 m².

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.343 %/°C
Voc coefficient β−0.269 %/°C
Isc coefficient α+0.045 %/°C
Operating cell temperatureNOCT 44.6 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
360 W266.9 W37.24 V × 7.17 A68 W94%
365 W270.6 W37.43 V × 7.23 A69 W94%
370 W274.3 W37.62 V × 7.29 A69.9 W94%
375 W278.1 W37.81 V × 7.36 A70.9 W95%
380 W282.1 W38 V × 7.43 A71.9 W95%
385 W285.3 W38.19 V × 7.47 A72.7 W94%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Independent reliability testing

Kiwa PVEL Scorecard · RETC PV Module Index
9
PVEL Scorecards
LONGi named Top Performer, 2017–2026
2023, 2024, 2025, 2026
RETC Overall Highest Achiever
LONGi, manufacturer level
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

RETC PV Module Index — LONGi

YearRecognition
2023Overall Highest Achiever; High Achievement in Performance (Pan file performance, Module efficiency, Lid resistance); High Achievement in Quality (Thresher test); High Achievement in Reliability (Thermal cycle test, SDML, Damp heat test)
2024Overall Highest Achiever
2025Overall Highest Achiever
2026Overall Highest Achiever; High achievement in performance; High achievement in reliability; Performance discipline high achiever (Iam, Letid, PAN file, PTC-to-STC); Quality discipline high achiever (BOM verification); Reliability discipline high achiever (Damp heat, Hdt, Pid, Sdml, Tc, Uvid)

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
51.1 V
Voc when cold
per panel
32.2 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V51.1 / 32.2 V✓ Within range1.28
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V51.1 / 32.2 V✗ Not a match: module voltage below MPPT range0.97
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V51.1 / 32.2 V✓ Within range0.47
Enphase IQ8M-72-2-US260–460 W60 V30–45 V51.1 / 32.2 V✓ Within range1.14
Enphase IQ8A-72-2-US295–500 W60 V32–45 V51.1 / 32.2 V✓ Within range1.06
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67662011,7826.08
Palmdale1,83567912,9006.69
Chula Vista1,69662811,9236.11
Huntington Beach1,64360811,5505.89
Riverside1,69662811,9236.21
Santa Clarita1,72463812,1206.28
769Jan770Feb988Mar1,091Apr1,078May1,145Jun1,206Jul1,220Aug1,067Sep941Oct809Nov700DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 370 W panels

CEC PV Module List (Oct 7, 2026) · Canadian Solar datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
LONGi LR6-72HBD-370MC370 W≈19%−0.34348.19.8brand 9×—
Canadian Solar CS3N-375MS {Blk}375 W≈19%−0.34243.511.2product 202346
REC Group REC370AA370 W≈21.9%−0.25844.110.55brand 9× (2016–2025)30
Trina Solar TSM-370DE06X.05(II)370 W≈20.3%−0.33945.210.4product 202223
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

About LONGi

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · RETC PV Module Index · building permits

Other series by SoCal permits

LR4-60HPB-xxxM · 193LR5-54HABB-xxxM · 64LR5-54HPB-xxxM · 22LR4-60HPH-xxxM · 19LR5-72HBD-xxxM · 1LR4-60HBD-xxxM · 1

Questions & answers

How efficient is the LONGi LR6-72HBD-370MC?

Calculated from the panel area (1.95 m²): about 19% for the 370 W class. 370 W over 1.95 m² equals about 190 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 620 kWh per year per 370 W panel in Los Angeles and about 679 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.343 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.8% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 51.1 V, Vmp at 74 °C cell = 32.2 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 51.1 V vs max input 60 V; Vmp when hot 32.2 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Is it bifacial?

Yes. Rear gain depends on mounting height and ground reflectance.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; LONGi was named a Top Performer in 9 Scorecards (2017–2026). RETC named LONGi Overall Highest Achiever in 2023, 2024, 2025, 2026.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2017–2026.
  4. RETC — PV Module Index reports 2023–2026.
  5. NLR (formerly NREL) — System Advisor Model CEC module and inverter libraries (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).