Cali-GrafCali-Graf
Solar panelLOF SOLAR

LOF SOLAR LOF-MH92-C 430

144 half-cut cells. Power classes 400–460 W in the CEC list.

CEC listed · May 1, 2023UL 61730
Power class
  • Power (STC)430 WCEC nameplate
  • Efficiency≈20.0%calculated from area
  • %/°C Pmax−0.397CEC listing test
  • PTC / STC92.3%PTC 397 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 13 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LOF-MH92-C400400 W48.2410.2840.739.85≈18.6%369 WMay 1, 2023
LOF-MH92-C405405 W48.2910.3240.989.89≈18.8%373 WMay 1, 2023
LOF-MH92-C410410 W48.3210.4541.0010.01≈19.1%378 WMay 1, 2023
LOF-MH92-C415415 W48.3510.6441.0110.17≈19.3%383 WMay 1, 2023
LOF-MH92-C420420 W48.3910.8141.0210.29≈19.5%388 WMay 1, 2023
LOF-MH92-C425425 W48.4510.8441.1010.35≈19.8%392 WMay 1, 2023
LOF-MH92-C430430 W48.6010.9141.2510.43≈20.0%397 WMay 1, 2023
LOF-MH92-C435435 W48.7511.0041.4010.51≈20.2%402 WMay 1, 2023
LOF-MH92-C440440 W48.9011.0941.5510.59≈20.5%406 WMay 1, 2023
LOF-MH92-C445445 W49.0511.1841.7010.67≈20.7%411 WMay 1, 2023
LOF-MH92-C450450 W49.2011.2741.8510.76≈20.9%416 WJun 1, 2023
LOF-MH92-C455455 W49.3511.3642.0010.84≈21.2%421 WJun 1, 2023
LOF-MH92-C460460 W49.5011.4542.1510.92≈21.4%426 WJun 1, 2023
≈ efficiency = Pmax ÷ CEC-listed area 2.15 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.397 %/°C
Voc coefficient β−0.323 %/°C
Isc coefficient α+0.067 %/°C
Operating cell temperatureNOCT 45 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
400 W284.6 W36.87 V × 7.72 A72 W90%
405 W287.5 W37.09 V × 7.75 A72.8 W90%
410 W291.2 W37.11 V × 7.85 A73.7 W90%
415 W295.9 W37.12 V × 7.97 A74.9 W90%
420 W299.5 W37.13 V × 8.06 A75.8 W90%
425 W301.8 W37.2 V × 8.11 A76.4 W90%
430 W305.2 W37.34 V × 8.17 A77.3 W90%
435 W308.7 W37.47 V × 8.24 A78.1 W90%
440 W312.2 W37.61 V × 8.3 A79 W90%
445 W315.7 W37.75 V × 8.36 A79.9 W90%
450 W319.5 W37.88 V × 8.43 A80.9 W90%
455 W323 W38.02 V × 8.5 A81.7 W90%
460 W326.5 W38.15 V × 8.56 A82.6 W90%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.2 V
Voc when cold
per panel
31.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V52.2 / 31.9 V✓ Within range1.48
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.2 / 31.9 V✗ Not a match: module voltage below MPPT range1.13
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.2 / 31.9 V✓ Within range0.55
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.2 / 31.9 V✓ Within range1.32
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.2 / 31.9 V⚠ Works; below MPPT at peak heat1.23
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672111,5316.08
Palmdale1,83578912,6256.69
Chula Vista1,69672911,6686.11
Huntington Beach1,64370611,3045.89
Riverside1,69672911,6686.21
Santa Clarita1,72474111,8616.28
753Jan753Feb967Mar1,068Apr1,055May1,121Jun1,181Jul1,194Aug1,044Sep921Oct792Nov685DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 430 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, AWarrantyPVEL (product / brand)SoCal permits (series)
LOF SOLAR LOF-MH92-C 430430 W≈20%−0.39748.610.91———
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.8625 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 430430 W≥22%−0.27639.3213.7425 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-430QD430 W≈22.1%−0.29438.9113.8725 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the LOF SOLAR LOF-MH92-C 430?

Calculated from the panel area (2.15 m²): about 20% for the 430 W class. 430 W over 2.15 m² equals about 200 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 721 kWh per year per 430 W panel in Los Angeles and about 789 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.397 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 20.6% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.2 V, Vmp at 74 °C cell = 31.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 52.2 V vs max input 60 V; Vmp when hot 31.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  3. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  4. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  5. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists.
  6. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  7. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  8. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  9. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  10. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).