Cali-GrafCali-Graf
Solar panelLG Electronics

LG Electronics LG400Q1C-A6

60 cells, N-type. Power classes 390–405 W in the CEC list; datasheet covers 390–390 W.

CEC listed · Feb 1, 2021UL 61730PVEL Top Performer 2021N-typeSeen in 1 SoCal permit
Power class
  • Power (STC)400 WCEC nameplate
  • Efficiency≈22.1%calculated from area
  • %/°C Pmax−0.29CEC test: −0.310
  • Degradation / yr0.25%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · LG Electronics datasheet · Cali-Graf calculation · 4 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG390Q1C-A6390 W43.5011.2636.7010.63≥21.5%364 WFeb 1, 2021
LG395Q1C-A6395 W43.6011.2937.0010.69≈21.8%369 WFeb 1, 2021
LG400Q1C-A6400 W43.8011.3237.2010.76≈22.1%374 WFeb 1, 2021
LG405Q1C-A6405 W43.9011.3537.5010.82≈22.3%379 WFeb 1, 2021
≈ efficiency = Pmax ÷ panel area 1.813 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

LG Electronics datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

LG Electronics datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.29 %/°C−0.310 %/°C
Voc coefficient β−0.24 %/°C−0.242 %/°C
Isc coefficient α+0.04 %/°C+0.027 %/°C
Vmp coefficient≈ −0.33 %/°C—
Operating cell temperatureNMOT 44 ± 3 °CNOCT 47.7 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
390 W290 W34.31 V × 8.45 A73.8 W95%
395 W294 W34.59 V × 8.5 A74.8 W95%
400 W297.5 W34.78 V × 8.55 A75.7 W95%
405 W301.6 W35.06 V × 8.6 A76.7 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

LG Electronics datasheet
Packaging: 25 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · LG Electronics datasheet
UL 61730IEC 61215IEC 61730IEC 61701IEC 62716Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

LG Electronics datasheet

Independent reliability testing

Kiwa PVEL Scorecard
2021
PVEL Top Performer
this series
1
Tests passed as Top Performer
LID+LETID
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021

PVEL Top Performer tests

YearProductTests
2021LGxxxQ1C-A6LID+LETID

Inverter compatibility & string sizing

LG Electronics datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
46.2 V
Voc when cold
per panel
31.2 V
Vmp when hot
per panel
12
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–12
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–12
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–12
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window8–10

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V46.2 / 31.2 V✓ Within range1.38
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V46.2 / 31.2 V✗ Not a match: module voltage below MPPT range1.05
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V46.2 / 31.2 V✓ Within range0.51
Enphase IQ8M-72-2-US260–460 W60 V30–45 V46.2 / 31.2 V✓ Within range1.23
Enphase IQ8A-72-2-US295–500 W60 V32–45 V46.2 / 31.2 V⚠ Works; below MPPT at peak heat1.15
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67667012,0676.08
Palmdale1,83573413,2126.69
Chula Vista1,69667812,2116.11
Huntington Beach1,64365711,8305.89
Riverside1,69667812,2116.21
Santa Clarita1,72469012,4136.28
788Jan788Feb1,012Mar1,117Apr1,104May1,173Jun1,236Jul1,250Aug1,093Sep964Oct829Nov717DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 400 W panels

CEC PV Module List (Oct 7, 2026) · Qcells datasheet · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
LG Electronics LG400Q1C-A6400 W≈22.1%−0.31043.811.32product 20211
Qcells Q.PEAK DUO BLK ML-G10+ 400400 W≥20.4%−0.36245.311.14product 2022, 2023221
JA Solar JAM54S31-400/MR400 W≈21.1%−0.32937.0713.79product 2023, 2024152
REC Group REC400AA Pure400 W≈22.3%−0.25648.810.25brand 9× (2016–2025)66
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the LG Electronics LG400Q1C-A6?

Calculated from the panel area (1.81 m²): about 22.1% for the 400 W class. 400 W over 1.81 m² equals about 221 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 670 kWh per year per 400 W panel in Los Angeles and about 734 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.29 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 15% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–12 panels per string (Voc at 2 °C = 46.2 V, Vmp at 74 °C cell = 31.2 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 46.2 V vs max input 60 V; Vmp when hot 31.2 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on the product: at least 92.5% after 25 years (manufacturer datasheet).

How big and heavy is it?

68.5 × 41 × 1.57 in (1,740 × 1,042 × 40 mm), 40.8 lb (18.5 kg).

Has this panel been reliability-tested?

LGxxxQ1C-A6 was a PVEL Top Performer in 2021 (LID+LETID).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. LG Electronics — manufacturer datasheet “LG390Q1C-A6 LG NeON® R is powerful solar module that provides world-class”.
  3. Qcells — manufacturer datasheet “Q.PEAK DUO BLK ML-G10+ ENDURING HIGH PERFORMANCE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Los Angeles County Public Works (EPIC-LA, unincorporated areas) (Dec 2021). Equipment matched from permit descriptions by model number.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).