72 cells. Power classes 390–430 W in the CEC list.
| Model | Pmax | Voc, V | Isc, A | Vmp, V | Imp, A | Efficiency | PTC | CEC listed |
|---|---|---|---|---|---|---|---|---|
| LG390N2W-L5 | 390 W | 49.10 | 10.39 | 39.80 | 9.81 | ≈18.8% | 362 W | Aug 11, 2020 |
| LG395N2W-L5 | 395 W | 49.20 | 10.43 | 40.20 | 9.83 | ≈19.1% | 367 W | Aug 11, 2020 |
| LG400N2W-L5 | 400 W | 49.30 | 10.47 | 40.60 | 9.86 | ≈19.3% | 372 W | Aug 11, 2020 |
| LG405N2W-L5 | 405 W | 49.40 | 10.51 | 41.00 | 9.89 | ≈19.5% | 376 W | Aug 11, 2020 |
| LG410N2W-L5 | 410 W | 49.50 | 10.55 | 41.40 | 9.91 | ≈19.8% | 381 W | Aug 11, 2020 |
| LG415N2W-L5 | 415 W | 49.60 | 10.59 | 41.80 | 9.94 | ≈20.0% | 386 W | Aug 11, 2020 |
| LG420N2W-L5 | 420 W | 49.70 | 10.63 | 42.10 | 9.98 | ≈20.3% | 391 W | Aug 11, 2020 |
| LG425N2W-L5 | 425 W | 49.80 | 10.67 | 42.50 | 10.01 | ≈20.5% | 396 W | Aug 11, 2020 |
| LG430N2W-L5 | 430 W | 49.90 | 10.71 | 42.90 | 10.04 | ≈20.7% | 400 W | Aug 11, 2020 |
| CEC listing test | |
|---|---|
| Pmax coefficient γ | −0.342 %/°C |
| Voc coefficient β | −0.258 %/°C |
| Isc coefficient α | +0.025 %/°C |
| Operating cell temperature | NOCT 46.2 °C |
| Class | Pmax at NOCT | Vmp × Imp at NOCT | Pmax at 200 W/m² | Low-light efficiency vs STC |
|---|---|---|---|---|
| 390 W | 288.4 W | 36.46 V × 7.91 A | 75.6 W | 97% |
| 395 W | 291.9 W | 36.82 V × 7.93 A | 76.5 W | 97% |
| 400 W | 295.7 W | 37.19 V × 7.95 A | 77.5 W | 97% |
| 405 W | 299.5 W | 37.56 V × 7.97 A | 78.5 W | 97% |
| 410 W | 303 W | 37.92 V × 7.99 A | 79.5 W | 97% |
| 415 W | 306.9 W | 38.29 V × 8.01 A | 80.5 W | 97% |
| 420 W | 310.3 W | 38.56 V × 8.05 A | 81.4 W | 97% |
| 425 W | 314.2 W | 38.93 V × 8.07 A | 82.4 W | 97% |
| 430 W | 318.1 W | 39.3 V × 8.1 A | 83.4 W | 97% |
| Inverter | Max DC input | MPPT | Window source | Panels per string |
|---|---|---|---|---|
| Tesla 1538000-xx-y | 600 V | 60–480 V | datasheet | 2–11 |
| Solis (Ginlong) S6-EH1P10K-H-US | 600 V | 80–520 V | datasheet | 3–11 |
| Solis (Ginlong) Solis-1P7.6K-4G-US | 600 V | 100–500 V | datasheet | 3–11 |
| Qcells Q.VOLT H7.6SX | 498 V | 234–498 V | CEC test window | 7–9 |
| Microinverter | Recommended module power | Max DC input | MPPT | Voc cold / Vmp hot | Check | DC/AC |
|---|---|---|---|---|---|---|
| Enphase IQ8PLUS-72-2-US | 235–440 W | 60 V | 29–45 V | 52.4 / 34 V | ✓ Within range | 1.41 |
| Enphase IQ8X-80-M-US | 320–540 W | 79.5 V | 43–60 V | 52.4 / 34 V | ✗ Not a match: module voltage below MPPT range | 1.08 |
| APsystems (Alt Power System) DS3-L | 265–570 W | 60 V | 28–45 V | 52.4 / 34 V | ✓ Within range | 0.53 |
| Enphase IQ8M-72-2-US | 260–460 W | 60 V | 30–45 V | 52.4 / 34 V | ✓ Within range | 1.26 |
| Enphase IQ8A-72-2-US | 295–500 W | 60 V | 32–45 V | 52.4 / 34 V | ✓ Within range | 1.17 |
| City | kWh / kW / yr | kWh / panel / yr | kWh / system / yr | Sun, kWh/m²/day |
|---|---|---|---|---|
| Los Angeles | 1,676 | 687 | 11,682 | 6.08 |
| Palmdale | 1,835 | 752 | 12,790 | 6.69 |
| Chula Vista | 1,696 | 695 | 11,821 | 6.11 |
| Huntington Beach | 1,643 | 674 | 11,452 | 5.89 |
| Riverside | 1,696 | 695 | 11,821 | 6.21 |
| Santa Clarita | 1,724 | 707 | 12,016 | 6.28 |
| Panel | Pmax | Efficiency | γ Pmax (CEC) | Voc, V | Isc, A | PVEL (product / brand) | SoCal permits (series) |
|---|---|---|---|---|---|---|---|
| LG Electronics LG410N2W-L5 | 410 W | ≈19.8% | −0.342 | 49.5 | 10.55 | brand 2× | — |
| Qcells Q.PEAK DUO BLK ML-G10+ 410 | 410 W | ≈20.9% | −0.337 | 45.37 | 11.2 | product 2022, 2023 | 221 |
| JA Solar JAM54S31-405/MR | 405 W | ≈21.3% | −0.329 | 37.23 | 13.87 | product 2023, 2024 | 152 |
| REC Group REC410AA Pure | 410 W | ≈22.9% | −0.256 | 49 | 10.35 | brand 9× (2016–2025) | 66 |
Calculated from the panel area (2.07 m²): about 19.8% for the 410 W class. 410 W over 2.07 m² equals about 198 W per square meter.
PVWatts v8 with typical-year weather gives about 687 kWh per year per 410 W panel in Los Angeles and about 752 kWh in Palmdale (20° roof, facing south, 14% system losses).
With γ = −0.342 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.7% below the STC rating.
With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.4 V, Vmp at 74 °C cell = 34 V). Final design must follow the inverter manual and NEC 690.7.
Voltage check against the Enphase datasheet: Voc when cold 52.4 V vs max input 60 V; Vmp when hot 34 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.
This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).