Cali-GrafCali-Graf
Solar panelLG Electronics

LG Electronics LG435N2T-E6

144 half-cut cells, N-type. Power classes 420–450 W in the CEC list; datasheet covers 430–490 W.

CEC listed · Feb 11, 2021UL 61730N-type
Power class
  • Power (STC)435 WCEC nameplate
  • Efficiency≈19.6%calculated from area
  • %/°C Pmax−0.33CEC test: −0.352
  • Degradation / yr0.35%after year 1 (warranty)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · LG Electronics datasheet · 7 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG420N2T-E6420 W48.5010.8240.5010.37≈18.9%388 WFeb 11, 2021
LG425N2T-E6425 W48.8010.8840.8010.42≈19.1%392 WFeb 11, 2021
LG430N2T-E6430 W49.1010.9441.1010.47≥19.4%397 WFeb 11, 2021
LG435N2T-E6435 W49.4011.0041.4010.51≈19.6%402 WFeb 11, 2021
LG440N2T-E6440 W49.7011.0641.7010.56≈19.8%406 WFeb 11, 2021
LG445N2T-E6445 W50.0011.1142.0010.61≈20.0%411 WAug 23, 2021
LG450N2T-E6450 W50.3011.1542.2010.67≈20.3%416 WAug 23, 2021
≈ efficiency = Pmax ÷ panel area 2.219 m² (datasheet size) for classes outside the datasheet.

Build & dimensions

LG Electronics datasheet · Cali-Graf calculation · CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

LG Electronics datasheet · CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
DatasheetCEC listing test
Pmax coefficient γ−0.33 %/°C−0.352 %/°C
Voc coefficient β−0.26 %/°C−0.272 %/°C
Isc coefficient α+0.04 %/°C+0.032 %/°C
Vmp coefficient≈ −0.37 %/°C—
Operating cell temperatureNMOT 42 ± 3 °CNOCT 47.4 °C
Vmp coefficient ≈ γ − α (datasheet); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
420 W305.3 W37.04 V × 8.24 A80 W95%
425 W309.1 W37.32 V × 8.28 A80.9 W95%
430 W312.9 W37.59 V × 8.32 A81.9 W95%
435 W316.3 W37.87 V × 8.35 A82.8 W95%
440 W320.1 W38.14 V × 8.39 A83.8 W95%
445 W324 W38.41 V × 8.43 A84.8 W95%
450 W327.4 W38.6 V × 8.48 A85.7 W95%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Electrical & strength ratings

LG Electronics datasheet
Packaging: 25 per pallet

Certifications

CEC PV Module List (Oct 7, 2026) · LG Electronics datasheet
UL 61730UL 1703IEC 61215IEC 61730IEC 61701IEC 62716Fire rating Type 1 (UL 61730)ISO 14001ISO 45001ISO 9001

Warranty & degradation

LG Electronics datasheet

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

LG Electronics datasheet · Cali-Graf calculation · NLR PVWatts v8 · CEC PV Module List (Oct 7, 2026) · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
52.4 V
Voc when cold
per panel
33.9 V
Vmp when hot
per panel
11
Max panels / string
max DC 600 V
2
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet2–11
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–11
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet3–11
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window7–9

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V52.4 / 33.9 V✓ Within range1.5
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V52.4 / 33.9 V✗ Not a match: module voltage below MPPT range1.14
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V52.4 / 33.9 V✓ Within range0.56
Enphase IQ8M-72-2-US260–460 W60 V30–45 V52.4 / 33.9 V✓ Within range1.34
Enphase IQ8A-72-2-US295–500 W60 V32–45 V52.4 / 33.9 V✓ Within range1.25
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67672911,6656.08
Palmdale1,83579812,7726.69
Chula Vista1,69673811,8046.11
Huntington Beach1,64371511,4355.89
Riverside1,69673811,8046.21
Santa Clarita1,72475011,9996.28
761Jan762Feb978Mar1,080Apr1,067May1,134Jun1,194Jul1,208Aug1,057Sep932Oct801Nov693DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 435 W panels

CEC PV Module List (Oct 7, 2026) · datasheets · Kiwa PVEL Scorecard · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, ASizeWarrantyPVEL (product / brand)SoCal permits (series)
LG Electronics LG435N2T-E6435 W≈19.6%−0.35249.41183.9 × 41 in—brand 2×—
Canadian Solar CS3N-430MS430 W≈21.8%−0.33245.711.86—25 yrproduct 202346
Qcells Q.TRON BLK M-G2+ 435435 W≥22.3%−0.27639.613.8267.8 × 44.6 in25 / 25 yrbrand 11× (2016–2026)40
Silfab Solar SIL-435QD435 W≈22.3%−0.29438.9414.0567.8 × 44.6 in25 / 30 yrbrand 7× (2017–2025)39
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Documents

manufacturer documents

Questions & answers

How efficient is the LG Electronics LG435N2T-E6?

Calculated from the panel area (2.22 m²): about 19.6% for the 435 W class. 435 W over 2.22 m² equals about 196 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 729 kWh per year per 435 W panel in Los Angeles and about 798 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.33 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.1% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 2–11 panels per string (Voc at 2 °C = 52.4 V, Vmp at 74 °C cell = 33.9 V). Final design must follow the inverter manual and NEC 690.7.

Does it work with Enphase IQ8PLUS-72-2-US microinverters?

Voltage check against the Enphase datasheet: Voc when cold 52.4 V vs max input 60 V; Vmp when hot 33.9 V vs MPPT low 29 V; recommended module power 235–440 W. Confirm on the microinverter maker’s compatibility list.

What does the warranty cover?

25 years on the product (manufacturer datasheet).

How big and heavy is it?

83.9 × 41 × 1.57 in (2,130 × 1,042 × 40 mm), 48.5 lb (22 kg).

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. LG Electronics — datasheet Specification Sheet.
  3. Canadian Solar — manufacturer datasheet “HiKu Mono PERC CS3N-400|405|410|415|420|425MS MORE POWER”.
  4. Qcells — manufacturer datasheet “Q.TRON BLK M-G2+ SERIES 415–440 Wp”.
  5. Silfab Solar — datasheet NTC SIL-420 QD CELL TECHNOLOGY.
  6. LG Electronics — document library on the manufacturer’s website (links above).
  7. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  8. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  9. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  10. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  11. Building permits — Southern California permit portals. Equipment matched from permit descriptions.