Cali-GrafCali-Graf
Solar panelLG Electronics

LG Electronics LG345N1W-N5

60 cells. Power classes 320–370 W in the CEC list.

CEC listed · Feb 3, 2020UL 61730
Power class
  • Power (STC)345 WCEC nameplate
  • Efficiency≈20.0%calculated from area
  • %/°C Pmax−0.342CEC listing test
  • PTC / STC93.4%PTC 322 W (CEC)

Power classes

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · 11 models
ModelPmaxVoc, VIsc, AVmp, VImp, AEfficiencyPTCCEC listed
LG320N1W-N5320 W40.8010.5331.9010.04≈18.5%298 WAug 11, 2020
LG325N1W-N5325 W40.9010.5732.3010.07≈18.8%303 WAug 11, 2020
LG330N1W-N5330 W41.0010.6132.7010.10≈19.1%308 WFeb 3, 2020
LG335N1W-N5335 W41.1010.6533.1010.13≈19.4%313 WFeb 3, 2020
LG340N1W-N5340 W41.2010.6933.5010.16≈19.7%318 WFeb 3, 2020
LG345N1W-N5345 W41.3010.7233.9010.19≈20.0%322 WFeb 3, 2020
LG350N1W-N5350 W41.4010.7634.3010.22≈20.3%327 WFeb 3, 2020
LG355N1W-N5355 W41.5010.8034.7010.25≈20.6%332 WFeb 3, 2020
LG360N1W-N5360 W41.6010.8435.1010.28≈20.9%337 WFeb 3, 2020
LG365N1W-N5365 W41.7010.8835.5010.30≈21.2%342 WAug 11, 2020
LG370N1W-N5370 W41.8010.9235.8010.34≈21.4%346 WAug 11, 2020
≈ efficiency = Pmax ÷ CEC-listed area 1.73 m².

Build & dimensions

CEC PV Module List (Oct 7, 2026)

Heat & cold behaviour

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation
CEC listing test
Pmax coefficient γ−0.342 %/°C
Voc coefficient β−0.257 %/°C
Isc coefficient α+0.032 %/°C
Operating cell temperatureNOCT 44.9 °C
Vmp coefficient ≈ γ − α (CEC); used only for the hot-roof voltage estimate.

Away from lab conditions — CEC listing test points

ClassPmax at NOCTVmp × Imp at NOCTPmax at 200 W/m²Low-light efficiency vs STC
320 W237.9 W30.05 V × 7.92 A62.4 W97%
325 W241.6 W30.43 V × 7.94 A63.3 W97%
330 W245.3 W30.81 V × 7.96 A64.3 W97%
335 W249 W31.18 V × 7.99 A65.3 W97%
340 W252.8 W31.56 V × 8.01 A66.3 W97%
345 W256.6 W31.94 V × 8.03 A67.3 W97%
350 W260.4 W32.31 V × 8.06 A68.3 W98%
355 W264.2 W32.69 V × 8.08 A69.3 W98%
360 W268 W33.07 V × 8.1 A70.3 W98%
365 W271.6 W33.44 V × 8.12 A71.2 W98%
370 W274.9 W33.73 V × 8.15 A72.1 W97%
Pmax = Vmp × Imp from the CEC listing; low-light efficiency = Pmax at 200 W/m² ÷ (20% of STC Pmax).

Certifications

CEC PV Module List (Oct 7, 2026)
UL 61730IEC 61215

Independent reliability testing

Kiwa PVEL Scorecard
2
PVEL Scorecards
LG Electronics named Top Performer, 2018–2021
This exact series is not listed in published PVEL Top Performer tables. Results below are for the manufacturer.

Inverter compatibility & string sizing

CEC PV Module List (Oct 7, 2026) · Cali-Graf calculation · NLR PVWatts v8 · inverter datasheets · NLR SAM inverter library · CEC Grid Support Inverter List (Oct 7, 2026)
43.7 V
Voc when cold
per panel
27.7 V
Vmp when hot
per panel
13
Max panels / string
max DC 600 V
3
Min panels / string
MPPT from 60 V
Defaults come from NLR TMY weather (coldest hour, hottest modeled cell). Code calculations (NEC 690.7) use the ASHRAE extreme annual minimum, which is usually colder — enter it above. β is the CEC-measured coefficient; NEC 690.7 calculations use the datasheet value.

String inverters most named in SoCal permits

InverterMax DC inputMPPTWindow sourcePanels per string
Tesla 1538000-xx-y600 V60–480 Vdatasheet3–13
Solis (Ginlong) S6-EH1P10K-H-US600 V80–520 Vdatasheet3–13
Solis (Ginlong) Solis-1P7.6K-4G-US600 V100–500 Vdatasheet4–13
Qcells Q.VOLT H7.6SX498 V234–498 VCEC test window9–11

Microinverters (one per panel)

MicroinverterRecommended module powerMax DC inputMPPTVoc cold / Vmp hotCheckDC/AC
Enphase IQ8PLUS-72-2-US235–440 W60 V29–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat1.19
Enphase IQ8X-80-M-US320–540 W79.5 V43–60 V43.7 / 27.7 V✗ Not a match: module voltage below MPPT range0.91
APsystems (Alt Power System) DS3-L265–570 W60 V28–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat0.44
Enphase IQ8M-72-2-US260–460 W60 V30–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat1.06
Enphase IQ8A-72-2-US295–500 W60 V32–45 V43.7 / 27.7 V⚠ Works; below MPPT at peak heat0.99
Voltage check against the microinverter datasheets — confirm the pairing on the manufacturer’s module compatibility list. Rows appear only when the panel’s power is inside the microinverter’s recommended module power range.
SolarEdge and other optimizer-based systems size strings by the optimizer rules — use the manufacturer’s designer. Reference inverters: most named in SoCal permits since Oct 2024.

Expected production in Southern California

NLR PVWatts v8 · Cali-Graf calculation
CitykWh / kW / yrkWh / panel / yrkWh / system / yrSun, kWh/m²/day
Los Angeles1,67657811,5646.08
Palmdale1,83563312,6626.69
Chula Vista1,69658511,7026.11
Huntington Beach1,64356711,3375.89
Riverside1,69658511,7026.21
Santa Clarita1,72459511,8966.28
755Jan756Feb969Mar1,071Apr1,058May1,124Jun1,184Jul1,198Aug1,047Sep924Oct794Nov687DeckWh per month · Los Angeles
Estimate for comparison, not a quote: shading, roof orientation and local losses change real output. Roof mount, 20° tilt, south, 14% system losses.

Compare with similar 345 W panels

CEC PV Module List (Oct 7, 2026) · Kiwa PVEL Scorecard · JinkoSolar datasheets · building permits
PanelPmaxEfficiencyγ Pmax (CEC)Voc, VIsc, APVEL (product / brand)SoCal permits (series)
LG Electronics LG345N1W-N5345 W≈20%−0.34241.310.72brand 2×—
LONGi LR4-60HPB-345M345 W≈19.5%−0.33940.211.06product 2021, 2022193
JinkoSolar JKM345M-60HBL345 W≈20.4%−0.40641.210.91brand 12× (2014–2026)45
REC Group REC345AA345 W≈20.5%−0.27943.410.12brand 9× (2016–2025)30
Same fields from the same sources for every row; ≈ efficiency is calculated from the listed area. Comparable series: other brands, same product group, power range covering this class.

Questions & answers

How efficient is the LG Electronics LG345N1W-N5?

Calculated from the panel area (1.73 m²): about 20% for the 345 W class. 345 W over 1.73 m² equals about 200 W per square meter.

How much energy does one panel produce in Los Angeles or Palmdale?

PVWatts v8 with typical-year weather gives about 578 kWh per year per 345 W panel in Los Angeles and about 633 kWh in Palmdale (20° roof, facing south, 14% system losses).

How much power does it lose on a hot roof?

With γ = −0.342 %/°C, at a 77 °C cell temperature (hottest modeled hour in Palmdale) output is about 17.7% below the STC rating.

How many panels fit on one string?

With the Tesla 1538000-xx-y (max DC 600 V, MPPT from 60 V, datasheet) in Los Angeles the calculator gives 3–13 panels per string (Voc at 2 °C = 43.7 V, Vmp at 74 °C cell = 27.7 V). Final design must follow the inverter manual and NEC 690.7.

Has this panel been reliability-tested?

This exact series is not in published PVEL Top Performer tables; LG Electronics was named a Top Performer in 2 Scorecards (2018–2021).

Sources

  1. California Energy Commission — Solar Equipment Lists, PV Module List, Inverter List (snapshot Oct 7, 2026).
  2. JinkoSolar — datasheet THE MOST DEPENDABLE SOLAR BRAND.
  3. JinkoSolar — manufacturer datasheet “Eagle HC 60M G2 315-335 Watt MONO PERC HALF CELL MODULE”.
  4. Kiwa PVEL — PV Module Reliability Scorecard, Top Performer lists 2018–2021.
  5. NLR (formerly NREL) — System Advisor Model CEC inverter library (version 2026.7.3).
  6. NLR (formerly NREL) — PVWatts v8, NSRDB PSM v3 typical-year weather for Los Angeles, Palmdale, Chula Vista, Huntington Beach, Riverside, Santa Clarita.
  7. Inverter datasheets — APsystems (Alt Power System), Enphase, Solis (Ginlong), Tesla (manufacturer documents).
  8. Building permits — Southern California permit portals. Equipment matched from permit descriptions.
  9. Cali-Graf calculations — formulas and inputs are shown next to each calculated value (efficiency from area, temperature-corrected voltages, string sizing, energy estimates).